• 제목/요약/키워드: Air discharge

검색결과 1,008건 처리시간 0.038초

공기유량에 따른 글로우 방전의 제전 특성 (Ionizing Characteristic of Glow Discharge by Controlled Air Flow Rate)

  • 최상원
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.49-53
    • /
    • 2008
  • Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. And more, ionizer was developed recently using an atmospheric pressure glow discharge. On the other hand, ionizer needs a compressed or blown air to transport ion for charged objects. This air is very useful in explosive hazardous area to prevent the explosion of flammable gas and/or vapor by ignition sources, e.g. electrical spark. In this paper, we investigated the ionizing characteristic of atmospheric pressure glow discharge by controlled air flow rate from 5 liters to 60 liters a minute, and compared with decay time between the corona discharge and glow discharge as a function of some direction and distance from discharge ion source. We confirmed that an air flow rate needs 25 liters a minute to sustain the most suitable atmospheric pressure glow discharge and to increase an ionizing efficiency.

난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화 (Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

유량조절이 가능한 사이펀 여수로 수리모형실험 (Hydrualic Model Test for Siphon Spillway Capable of Controlling Discharge)

  • 정재상;장은철;이창훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.43-47
    • /
    • 2019
  • 본 연구에서는 수리모형실험을 통해 사이펀 여수로에 장착된 air slot의 방류량 조절 능력을 검토하였다. air slot의 단면 형상으로 원호 및 직사각형 형상을 채택하였으며, 개구부 면적을 조절할 수 있게 하였다. air slot이 장착된 경우 사이펀 관 내부에 공기와 물이 혼합된 복잡한 흐름이 발생하였다. air slot이 장착된 사이펀 여수로에서 저수지 내측 수위가 상승할 때와 하강할 때 동일한 수위에서 동일한 유량이 계측되었다. air slot의 무차원 개구부 면적이 증가할수록 무차원 방류량은 더 서서히 증가하였다. 수리모형실험 결과는 air slot의 면적 조절을 통해 사이펀을 통한 방류량 조절이 가능함을 보여주었다.

  • PDF

Experimental Study on Air Decomposition By-Product Under Creepage Discharge Fault and Their Impact on Insulating Materials

  • Javed, Hassan;LI, Kang;Zhang, Guoqiang;Plesca, Adrian Traian
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2392-2401
    • /
    • 2018
  • Creepage discharge faults in air on solid insulating material play a vital role in degradation and ageing of material which ultimately leads to breakdown of power equipment. And electric discharge decompose air in to its by-products such as Ozone and $NO_x$ gases. By analyzing air decomposition gases is a potential method for fault diagnostic in air. In this paper, experimental research has been conducted to study the effect of creepage discharge on rate of generation of air decomposition by-products using different insulating materials such as RTV, epoxy and fiberglass laminated sheet. Moreover XRF analysis has been done to analyze creepage discharge effect on these insulating materials. All experiments have been done in an open air test cell under constant temperature and pressure conditions. While analysis has been made for low and high humidity conditions. The results show that the overall concentration of air decomposition by-products under creepage discharge in low humidity is 4% higher than concentration measured in high humidity. Based on this study a mathematical relationship is also proposed for the rate of generation of air decomposition by-products under creepage discharge fault. This study leads to indirect way for diagnostic of creepage discharge propagation in air.

공기 양정(air lift) 펌프를 응용한 슬러지 배출장치에 대한 연구 (Application of Air Lift Pump for Sludge Discharger)

  • 안갑환;박영식
    • 한국환경과학회지
    • /
    • 제13권10호
    • /
    • pp.929-938
    • /
    • 2004
  • Sludge discharger applied the principle of the air lift pump was investigated experimentally for the different design( diameter of discharge pipe, diameter and height of the inside and outside wall) and operating parameters(air flow rate, water level). And it was conducted that performance comparison about sludge discharger and conventional air lift pump. The result indicated that discharged liquid were increased with the increase of air flow rate and water level and decrease distance between inside and outside wall. The discharge pressure was increased with an increase of air flow rate and a decrease of the diameter of the discharge pipe, for both the sludge discharger and the airlift pump. The discharge pressures of the sludge discharger were 3-6 times higher than those of the air lift pump.

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

수평배수재의 불포화 통수특성 연구 (A Study on the Characteristics of Unsaturated Discharge Capacity of Horizontal Drains)

  • 장연수;박정순;박정용
    • 한국지반공학회논문집
    • /
    • 제19권2호
    • /
    • pp.15-25
    • /
    • 2003
  • 수평배수재 내의 기포로 인한 불포화상태가 통수능에 미치는 영향을 평가하기 위하여 단면 크기 및 코어 형태에 따라 4종류의 배수재를 선정하여 불포화 통수능력시험을 실시하였다. 가압시간, 구속압, 동수경사 등의 변화에 따른 불포화 통수능의 변화를 분석하고 포화 통수능과 비교하였다. 분석결과, 불포화 통수능은 동수경사가 0.01인 경우, 포화 통수능에 비해 배수재 내에 적체된 잔류기포의 영향으로 인해 17%~80% 감소하였다. 이는 수평배수재의 경우, 수평으로 흐르는 물의 흐름 방향과 부양되려는 기포의 이동방향이 서로 일치하지 않기 때문으로 평가된다. 특히 배수재의 코어 형상이 필라멘트 모양인 경우 기포가 빠져나가기 어려워 불포화 통수능이 크게 저하되었다.

MnO2입자 크기에 따른 아연공기전지의 특성연구 (Size Effects of the Catalyst on Characteristics of Zn/Air Batteries)

  • 김지훈;엄승욱;문성인;윤문수;김주용;박정식;박정후
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1150-1154
    • /
    • 2003
  • The voltage profile during discharge of the zinc air battery has very flat pattern until reach to end of discharge voltage. But, when zinc air battery is discharged by high current, the discharge voltage and energy becomes low. Therefore, we focused on effects of catalyst size to solve this problems by increasing active sites of oxygen reduction reaction. The size of catalyst was reduced from 27 to l${\mu}{\textrm}{m}$ and we examined average discharge voltage, capacity, energy, resistance and characteristics during GSM pulse discharge of zinc air battery with change of current density. And we also measured porosity of the cathode according to the ASTM. So we have got improvement of average discharge voltage and energy when catalyst was minimized and we have got optimum size of catalyst at 5${\mu}{\textrm}{m}$.

전기집진기형 공기청정기의 미세 먼지 저감 특성에 관한 연구 (Characteristics of the Reduction of Fine Particles in an Indoor Air Cleaner Using Electrostatic Precipitation Technique)

  • 목영선;이호원
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.115-120
    • /
    • 2004
  • An indoor air cleaner consisting of a dielectric barrier discharge system and an electrostatic precipitator (ESP) was experimentally investigated. The function of the dielectric barrier discharge is to precharge particles by producing nonthermal plasma before indoor air enters ESP, leading to an enhancement in dust collection efficiency. The dependence of particle size distribution on the plasma discharge was examined to understand the mechanism of the particle precharging. The plasma discharge was found to increase the electrical force of the particles, rather than agglomerate them. Coarse particles in the range of 0.5 to $5.0{\mu}m$ were observed to be easily collected by this indoor air cleaner, and the present study laid emphasis on the removal of fine particles of $0.3{\mu}m$. The collection efficiency of the fine particles was largely enhanced by the plasma discharge.

  • PDF