• 제목/요약/키워드: Air diffuser

검색결과 184건 처리시간 0.018초

폐색 저감형 산기관의 개발 및 적용성 평가 (A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser)

  • 김영훈;김관엽;이의종;남종우;이창하;전민정;김형수
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.

거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구 (A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space)

  • 임석영;장현재
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

산기식 물순환장치 설계인자 연구: 현장 댐 조건을 고려한 CFD 해석 중심 (A Study on Design Factors of Air Diffuser Systems in Reservoirs: Application of Field Conditions to the CFD Simulation)

  • 신상민;이승재;이상은;박희경;염경택
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.161-169
    • /
    • 2011
  • This study aims at examining the design factors of the air diffuser system in a particular view of field conditions, and thus improving the procedures currently applied to design the system. First, the CFD model is built for an air diffuser system suitable for field conditions of real reservoirs. Then, the design factors, including destratification number, destratification radius and efficiency of the air diffuser system, are analyzed after a series of simulations over various field conditions. The result shows successful correlations of design factors with DN at the condition, and they lead to estimate of the destratification radius and efficiency of air diffuser system based on DN. It is finally concluded that the design factors are improved such that the air diffuser system is suitable for the field conditions of dam reservoirs.

소형 디퓨저의 최적화 설계 (Optimization Design of Compact Diffuser)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.163-167
    • /
    • 2022
  • In this paper, an optimization design method of a diffuser using Bernoulli's theorem was reviewed. The aspect ratio of the cylindrical diffuser chamber and the diameter ratio of the air inlet and outlet were used as design parameters. For the optimal design of the cylindrical diffuser chamber, the air flow inside the chamber was simulated using ANSYS while changing the aspect ratio of the chamber. In order to confirm the simulation results, the diffuser manufactured using the laser processing machine was measured. Through ANSYS simulation and measurement, it was found that the optimal design condition was when the aspect ratio (chamber height/radius) of the diffuser chamber was 1/2 and the diameter ratio of the air inlet and outlet was also 1/2.

축열조 성능에 미치는 디퓨저 형상의 영향 (Effect of Diffuser Shape on the Performance of Water-Chilled Heat Storage)

  • 정재동;박주혁;조성환
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.374-382
    • /
    • 2004
  • Diffuser design is crucial for water-chilled heat storage. Its impact on the system performance is more significant for the underground tank due to inherent limit on the aspect ratio and tank shape. The effect of diffuser shape on the performance of the water-chilled heat storage is numerically investigated. Three dimensional simulation has been conducted for fully incorporating the complex diffuser shape and the non-symmetric tank shape. Mixing at the inlet of the diffuser depends on the inlet Reynolds number, Froude number and the diffuser shape. Three types of the diffuser shape and the broad range of Reynolds number (Re=400, 800, 1200) and Froude number (Fr=0.5, 1.0, 2.0) are examined. The performance of the heat storage tank is evaluated by the thermocline thickness which is reverse to the degree of stratification. The radial regulated plate diffuser, which is the suggested diffuser shape in this study, shows the lowest thermocline thickness in the condition considered.

Air-Water Two-Phase Flow Performances of Centrifugal Pump with Movable Bladed Impeller and Effects of Installing Diffuser Vanes

  • Sato, Shinji;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권3호
    • /
    • pp.245-252
    • /
    • 2010
  • It's known that pump head of centrifugal impeller with lager blade outlet angle is kept higher in air-water two phase flow condition, though the efficiency in water single phase flow condition is inferior. In the present study, a centrifugal impeller with variable blade outlet angles, that has higher efficiencies in both water single phase flow and air-water two phase flow conditions, is proposed. And the performances of the centrifugal impeller with variable blade outlet angles were experimentally investigated in both flow conditions of single and two-phase. In addition, effects of installing diffuser vanes on the performances of centrifugal pump with movable bladed impeller were also examined. The results are as follows: (1) The movable bladed impeller that proposed in this study is effective for higher efficiency in both water single phase and air-water two phase flow conditions. (2) When diffuser vanes are installed, the efficiency of movable bladed impeller decreases particularly at large water flow rate in water single-phase flow condition; (3) The performances of movable bladed impeller are improved by installing of diffuser vanes in air-water two-phase flow condition at relatively small water rate. The improvement by installing of diffuser vanes however disappears at large water flow rate.

원뿔형 산기관 설계와 생물반응조에서 수력학적 운전특성에 관한 실험 및 해석 (Conical Diffuser Design and Hydraulic Performance Characteristics in Bioreactor Using Empirical and Numerical Methods)

  • 이승진;고경한;고명한;양재경;김용국
    • 대한기계학회논문집B
    • /
    • 제39권8호
    • /
    • pp.633-643
    • /
    • 2015
  • 본 연구의 목적은 고효율 미세기포 공급장치인 산기관을 개발하기 위하여, 미세기포를 이용하여 하폐수에 용존산소를 효율적으로 공급하고 슬러지에 의한 기공의 막힘을 최소화함으로써 호기성 미생물에 의한 유기물 분해공정의 효율성과 내구성을 개선하고자 하였다. 종래의 미세기포 산기관을 개선하기 위하여, 실험과 전산해석 방법을 이용하여 미세기포를 발생시키면서 슬러지에 의한 막힘현상이 없는 원뿔형 산기관을 개발하였다. 전산해석을 통하여 단위 산기관 내부의 공기유동패턴을 확인하여 산기관 설계를 보완하고, 모의 생물반응기에 단위 산기관을 적용하여 발생 기포 거동 실험과 2상유체유동에 대한 전산해석을 수행하였다. 실험 결과로서 모의 생물반응기 내에서 발생기포 수직 길이 및 상승속도 등 기포거동에 대한 통계치를 도출하였으며, 전산해석 결과로서 기포군의 거동을 포함한 유동특성에 대한 메커니즘을 규명하였다. 이를 통하여 고효율 산기관 설계를 체계화하였고 모의 생물반응기 내에서 기포거동과 내부유동 현상을 규명함으로써, 실증 수처리장 규모 생물반응기에 산기관 군체를 적용하여 산소전달특성 및 내부유동특성을 파악하고 시스템을 설계하는데 중요한 근거를 제시하였다.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

온도 성층축열조 가시화 및 실증분석에 관한 고찰 (Effect on Stratification due to Diffuser Shape in a Thermal Storage Tank)

  • 이영수;이상남;김종률
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.990-997
    • /
    • 2005
  • The stratified effect was investigated with three different types of diffuser shape in a thermal storage tank with variation of diffuser diameter, velocity, Froude number etc. Its effect was estimated by the degree of stratification. No matter of diffuser diameter and shape, the degree of stratification was the best as the Froude number gets closer to 1. In the case of a curved diffuser, when its diameter is a quarter of tank diameter and ejection velocity in a diffuser is approximately 0.2 m/s, the Froude number was almost 1. In the case of a flatted diffuser, when ejection velocity was 0.05 m/s, the Froude number was 1.5. Both cases which Froude number were nearer 1, showed the good degree of stratification.