• 제목/요약/키워드: Air data system

검색결과 2,226건 처리시간 0.03초

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

Flight Test Measurement and Assessment of a Flapping Micro Air Vehicle

  • Kim, Jong-Heon;Park, Chan-Yik;Jun, Seung-Moon;Chung, Dae-Keun;Kim, Jong-Rok;Hwang, Hee-Chul;Stanford, Bret;Beran, Philip;Parker, Gregory;Mrozinski, Denny
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권2호
    • /
    • pp.238-249
    • /
    • 2012
  • Flight test of flapping micro air vehicles (FMAVs) is carried out using an instrumented measurement system to obtain various engineering parameters and hence to assess the flight performance of the vehicles through the data investigation. An indoor flight test facility equipped with a motion capture system and tracking cameras is used for the work presented in this paper. Maneuvers including straight-level flight, ground flapping, takeoff and landing are tested. Spatial position and orientation data are obtained from the retro-reflective tracking markers attached to the vehicles. Subsequent test analysis is carried out by generating performance parameters from raw data and then assessing the flight performance by comparison of the vehicles. The main findings of this work confirm that the test method and procedures presented here enable the systematic numerical data measurement and assessment of the flying performances of these vehicles, and show the applicability for the test and evaluation of general flapping MAVs.

외기 도입에 따른 바닥급기 시스템의 에너지 사용량 분석 (Analysis of the Energy Consumption in Underfloor Air Distribution System depending on Outdoor Air Intake Rates)

  • 김동희;허정호;조동우;유기형;유지용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.826-831
    • /
    • 2006
  • In this paper, we discussed the energy performance of underfloor air distribution(UFAD) and overhead air distribution system according to outdoor air intake rates in a office building. For this, the laboratory(S lab.) is selected for measuring the thermal environments of UFAD system and overhead system. Based on the measured data, the TRNSYS simulation is used to evaluate the energy performance of UFAD system and the overhead system according to outdoor air intake rates. By increasing outdoor air intake rates from required outdoor air intake rates(100CMH) to maximum air intake rates, the energy savings of UFAD system comparing with overhead system are varied $15%{\sim}25.6%$ in summer, $12.8%{\sim}19%$ in fall/spring and not varied in winter(8%). As results of simulations on stratification height and cooling set temperature, the lower the stratification height and the higher cooling set temperature, the larger cooling energy savings of UFAD comparing with overhead system according to outdoor air intake rates.

  • PDF

Computer Simulation of an Automotive Air-Conditioning in a Transient Mode

  • Oh, Sang-Han;Won, Sung-Pil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.220-228
    • /
    • 2002
  • The cool-down performance after soaking is very important in an automotive air-conditioning system and is considered as a key design variable. Therefore, transient characteristics of each system component are essential to the preliminary design as well as steady-state performance. The objective of this study is to develop a computer simulation model and ostinato theoretically the transient performance of an automotive air-conditioning system. To do that, the mathematical modelling of each component, such as compressor, condenser, receiver/drier, expansion valve, and evaporator, is presented first of all. The basic balance equations about mass and energy are used in modelling. For detailed calculation, condenser and evaporator are divided into many sub-sections. Each sub-section is an elemental volume for modelling. In models of expansion valve and compressor, dynamic behaviors are not considered in this analysis, but the quasisteady state ones are just considered, such as the relation between mass flow rate and pressure drop in expansion device, polytropic process in compressor, etc. Also it is assumed that there are no heat loss and no pressure drop in discharge, liquid, and suction lines. The developed simulation model is validated by comparing with the laboratory test data of an automotive air-conditioning system. The overall time-tracing properties of each component agreed well with those of test data in this case.

소형 항공기 개발 동정압계통 오차 확인 비행시험 사례 (Study on Flight Test Practice of the Small Civil Airplane Development for Pitot-Static System's Error Identification)

  • 김찬조;서지한;이원중
    • 항공우주시스템공학회지
    • /
    • 제7권3호
    • /
    • pp.33-38
    • /
    • 2013
  • The air data measured from the static pressure, the dynamic pressure and etc. of an airplane is used for calculation of many flight parameters(altitude and airspeed and so on) and these values applied to flight safety and navigation flight. The pitot-static system of the development airplane is calibrated by finding of pitot-static system's error using tower fly-by, trailing cone method and etc. This paper is describing for the introduction of the trailing cone method and major items for test planning, preparation, operation and results for air data calibration flight test performed, considering efficiency and safety during KC-100 development project.

Utilization of Spatial Weather Information System for Effective Air Operations

  • Kim, Young-Hae;Yoon, Soungwoong;Lee, Sang-Hoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권4호
    • /
    • pp.139-145
    • /
    • 2018
  • In this paper, we propose the methodology and system to show weather information to spatial system. When using the spatial information system, it is easy and convenient to show information such as target location, mission contents, enemy threats and so on. However, drawing 1-dimensional weather information on 3-dimensional space in spatial information system is hard task. To fuse data, we need to add a spatial layer including weather information to spatial layers and perform space modeling for showing weather information as spatial data in a virtual space. The virtual space is shown by receiving meteorological data and then changing in real time through weather database linkage.

CFD를 이용한 피트의 지중열 모델 구축에 관한 연구 (A Geothermal Model of Pit Area Using Computational Fluid Dynamics)

  • 민준기;김정태
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.11-16
    • /
    • 2008
  • This research has established CFD model on pit's cool-tube system through heat and air movement simulations, of which data was based on experimental and verification. This research work verified the effectiveness of the cool-tube system by analysing temperature, humidity and air current of the actually installed case. Also, we analysed heat transfer through air current simulation and the results are as followings. Firstly, we experiment on temperature, humidity and speed of air currents of the cool tube system with pit space during the month of May (spring). The average exterior temperature was $16.1^{\circ}C$, and $18.2^{\circ}C$ for the pit, $24.7^{\circ}C$ for the compressor room. Secondly, based on measured data of real case, we have analysed heat transfer through air current simulation and verified our proposed model. The actual measurement of average temperature of exhaust air of the pit's area is $19.7^{\circ}C$ with tolerance of $-0.33^{\circ}C{\sim}-0.6^{\circ}C$ compared to above simulations. Thirdly, having verified air current simulation model with formation of 260,000 and 1,000,000 cells, we could get reasonable near values with 260,000 cells. Lastly, the next step of research would be focused on proposing the best possible pit's cool-tube system after analysis of heat transfer of the air current simulation based on verified CFD model.

대기오염(大氣汚染) 감시(監視) 및 예측(豫測) 시스템 개발 (Development of an Air Pollution Monitoring and Forecasting System)

  • 장동일;이태원;홍욱희;홍윤
    • Journal of Biosystems Engineering
    • /
    • 제17권2호
    • /
    • pp.177-191
    • /
    • 1992
  • The MAFSAP(Monitoring and Forecasting System of Air Pollution) was developed to measure the weather and air pollution data automatically, then make them input to microcomputer and analyze them for monitoring and forecasting air pollution at all times. And the air pollution telemetering systems installed at Young-Dong Thermal Power Plant was analyzed and an ideal telemetering system utilizing MAFSAP was suggested.

  • PDF

폴리머 열교환기를 사용한 냉각/재가열 시스템의 성능에 관한 연구 (A Study on the Performance of Cooling/Reheating System Using Polymer Heat Exchanger)

  • 김진혁;유성연;한규현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2154-2159
    • /
    • 2008
  • In conventional air-conditioning systems, when the circulated air from the air-conditioned space pass through the cooling coil in the air-conditioning system, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to test and evaluate performance of the cooling/reheating system which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. Experimental apparatus consists of fan, ducts, polymer exchangers, cooling coil, electronic auxiliary heater and data acquisition system. Two types of polymer exchanger, plate type and dimple type, made of polypropylene for cooling/reheating system are designed. Heat transfer and dehumidification characteristics of system are tested. The results show that the energy saving is up to 40% in the range of present experimented conditions, and it decreases with increasing velocity, inlet temperature and specific humidity.

  • PDF

GIS를 이용한 대기오염정보시스템 개발에 관한 연구 (A Study on Developing Environmental Information Systems for Presenting Air Pollution Emission Data Using GIS)

  • 이봉규
    • 한국공간정보시스템학회 논문지
    • /
    • 제1권1호
    • /
    • pp.39-48
    • /
    • 1999
  • 본 논문은 GIS를 이용하여 대기오염도 정보를 전달하는 환경정보시스템을 연구하는 것을 목적으로 한다. 본 연구에서는 ArcView 3.1과 수치지도를 이용하여 환경정보시스템을 개발하였다. 본 논문은 4장으로 구성되어 있는데, 서론에 이어 제2장에서는 대기오염정보 전달시스템의 현황을 서울시를 중심으로 살펴본다. 제3장에서는 본 연구를 통해 구현된 인터페이스와 시스템을 설명하고, 마지막 장에서는 요약으로 결론을 맺기로 한다.

  • PDF