• 제목/요약/키워드: Air content

검색결과 2,474건 처리시간 0.039초

Effect of polymer addition on air void content of fine grained concretes used in TRCC

  • Daskiran, Esma Gizem;Daskiran, Mehmet Mustafa;Gencoglu, Mustafa
    • Computers and Concrete
    • /
    • 제20권2호
    • /
    • pp.165-176
    • /
    • 2017
  • Textile Reinforced Cementitious Composite (TRCC) became the most common construction material lately and have excellent properties. TRCC can be employed in the manufacture of thin-walled facade elements, load-bearing integrated formwork, tunnel linings or in the strengthening of existing structures. These composite materials are a combination of matrix and textile materials. There isn't much research done about the usage of polymer modified matrices in textile reinforced cementitious composites. In this study, matrix materials named as fine grained concretes ($d_{max}{\leq}1.0mm$) were investigated. Air entraining effect of polymer modifiers were analyzed and air void content of fine grained concretes were identified with different methods. Aim of this research is to study the effect of polymer modification on the air content of fine grained concretes and the role of defoamer in controlling it. Polymer modifiers caused excessive air entrainment in all mixtures and defoamer material successfully lowered down the air content in all mixtures. Latex polymer modified mixtures had higher air content than redispersible powder modified ones. Air void analysis test was performed on selected mixtures. Air void parameters were compared with the values taken from air content meter. Close results were obtained with tests and air void analysis test found to be useful and applicable to fine grained concretes. Air void content in polymer modified matrix material used in TRCC found significant because of affecting mechanical and permeability parameters directly.

압력센서를 이용한 디지털 콘크리트 공기량 시험기 개발에 관한 연구 (Study of Digital Air Meter Used Pressure Sensor for Air Content of Freshly Mixed Concretes)

  • 윤인준;이경문;서인호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.566-569
    • /
    • 2006
  • The purpose of this study is to develop digital air meter used pressure sensor for measurement of air content in freshly mixed concrete by pressure method. The digital air meter can enhanced measurement accuracy and uniformity of air content in freshly concretes, according to use of pressure sensor and measuring process automation. Finally, the digital air meter in this study is improved reproducibility and reliability of measurement compared with analog air meter.

  • PDF

고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향 (Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance)

  • 김생빈
    • 콘크리트학회지
    • /
    • 제4권1호
    • /
    • pp.89-96
    • /
    • 1992
  • 콘크리트의 내동해성은 일반적으로 공기량이나 기포조직 및 분포에 따라 크게 영향을 받으며 콘크리트의 강도와도 관련이 있는 것으로 알려져 있다. 본 연구에서는 고강도콘크리트의 동결융해 저항성에 미치는 공기량 및 기포조직 특히 간격계수의 영향에 관한 실험적 연구로서 우선 압축강도는 Non-AE콘크리트를 대상으로 400-500kg/$\textrm{cm}^2$를 목표로 하였고, 실험결과 내구성지수가 10~20%정도에 불과하므로 다음단계로 공기량 2~12%인 AE콘크리트로 하여 내구성 향상을 도모하였다. 이 때 단위시멘트량, 물\ulcorner시멘트비등을 변화시킨 20종류의 콘크리트 배합에 대해 500cycle까지 동결융해시험을 실시하였다. 결론적으로 동결융해의 저항성은 물\ulcorner시멘트비 보다는 공기량과 더 밀접한 관계가 있었고 임계내구성지수에 대응하는 간격계수는 물\ulcorner시멘트비에 따라 다르다는 사실을 알 수 있었다.

Expansion ratio estimation of expandable foam grout using unit weight

  • WooJin Han;Jong-Sub Lee;Thomas H.-K. Kang;Jongchan Kim
    • Computers and Concrete
    • /
    • 제33권4호
    • /
    • pp.471-479
    • /
    • 2024
  • In urban areas, appropriate backfilling design is necessary to prevent surface subsidence and subsurface cavities after excavation. Expandable foam grout (EFG), a mixture of cement, water, and an admixture, can be used for cavity filling because of its high flowability and volume expansion. EFG volume expansion induces a porous structure that can be quantified by the entrapped air content. This study observed the unit weight variations in the EFG before and after expansion depending on the various admixture-cement and water-cement ratios. Subsequently, the air content before and after expansion and the gravimetric expansion ratios were estimated from the measured unit weights. The air content before expansion linearly increased with an increase in the admixture-cement ratio, resulting in a decrease in the unit weight. The air content after the expansion and the expansion ratio increased nonlinearly, and the curves stabilized at a relatively high admixture-cement ratio. In particular, a reduced water-cement ratio limits the air content generation and expansion ratio, primarily because of the short setting time, even at a high admixture-cement ratio. Based on the results, the relationship between the maximum expansion ratio of EFG and the mixture ingredients (water-cement and admixture-cement ratios) was introduced.

고강도 콘크리트의 동해저항에 관한 기포조직의 영향 (Effect of Air Void Organization to Frost-Resistance in High-Strength Concrete)

  • 김생빈;홍찬홈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.5-10
    • /
    • 1991
  • This study was performed to find out the effect about the spacing factor and durability factor to evaluate the durability of concrete in high-strength concrete with freezing and thawing as following each condition, 1) unit cement content : 500kg/$\textrm{m}^3$, 550kg/$\textrm{m}^3$ 2) water/cement ratio : 25%, 30%, 35% 3) air content : below 1.5%, 1.6~3.5%, 4~6%, over 7% From the results tested, a variation of air content was more effective to the durability of concrete than that of water/cement ratio and unit cement content.

  • PDF

시료 두께에 의한 저온진공건조기의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of the Low Temperature Vacuum Dryer by Material Layers)

  • 최순열;문수범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.226-232
    • /
    • 2002
  • In tradition, there have been two kinds of drying methods, which are sun drying and artificial drying. The sun drying method which has been adopted traditionally has been replaced by the hot-air drying method which is one of the most general methods of artificial drying, with its simple drying system, low initial cost of drying plant, and easy operating method. But the hot-air drying method has some defects ; (1)much energy loss happens due to the discharge of hot air during the drying process, (2)control of drying rate is not easy on account of changing relative humidity of inlet air for uniform hot air temperature, (3)high temperature of floods in drying process brings about the production of low-grade drying products. Also, the hot-air drying method is inducing environmental and sanitary problems which are resulting from the emission of high temperature and high humidity air, including stick on the drying progress. Vacuum drying technique, whose drying time and 7uantity of exhausting energy is about 1/3 ~1/4 of hot air drying, is very excellent in the drying efficiency. As the results, it took about 20 hours for material to reach about 18% of the final moisture content in order to store products for a long time, from about 470% of the early moisture content at the beginning of drying, and maximum drying rate comes to about $0.35 kg/m^2hr$ at about 350% of the moisture content.

롤러 전압 콘크리트 포장의 공기량 및 기포간격계수와 장기 내구성의 상관관계 분석을 위한 실험적 연구 (Experimental Study on Correlation Analysis of Air-void, Air-spacing factor and Long-term Durability for Roller-compacted Concrete pavement)

  • 이준희;이승우
    • 한국도로학회논문집
    • /
    • 제18권1호
    • /
    • pp.63-72
    • /
    • 2016
  • PURPOSES : The use of roller-compacted concrete pavement (RCCP) is an environmentally friendly method of construction that utilizes the aggregate interlock effect by means of a hydration reaction and roller compacting, demonstrating a superb structural performance with a relatively small unit water content and unit cement content. However, even if an excellent structural performance was secured through a previous study, the verification research on the environmental load and long-term durability was conducted under unsatisfactory conditions. In order to secure longterm durability, the construction of an appropriate internal air-void structure is required. In this study, a method of improving the long-term durability of RCCP will be suggested by analyzing the internal air-void structure and relevant durability of roller-compacted concrete. METHODS : The method of improving the long-term durability involves measurements of the air content, air voids, and air-spacing factor in RCCP that experiences a change in terms of the kind of air-entraining agent and chemical admixture proportions. This test should be conducted on the basis of test criteria such as ASTM C 457, 672, and KS F 2456. RESULTS : Freezing, thawing, and scaling resistance tests of roller compacted concrete without a chemical admixture showed that it was weak. However, as a result of conducting air entraining (AE) with an AE agent, a large amount of air was distributed with a range of 2~3%, and an air void spacing factor ranging from 200 to $300{\mu}m$ (close to $250{\mu}m$) coming from PCA was secured. Accordingly, the freezing and thawing resistance was improved, with a relative dynamic elastic modulus of more than 80%, and the scaling resistance was improved under the appropriate AE agent content rate. CONCLUSIONS : The long-term durability of RCCP has a direct relationship with the air-void spacing factor, and it can be secured only by ensuring the air void spacing factor through air entraining with the inclusion of an AE agent.

플라이애쉬 혼합 모르터의 공기연행특성에 대한 연구 (A Study on the Air-Entrained Properties in mortar Using Fly-ash)

  • 하상욱;김진춘;노갑수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.137-140
    • /
    • 1998
  • An entrained air is important in improving freeze/thaw resistance to the concrete structures. To achieve a proper degree of air entrainment, air entraining admixtures(AEA) are typically added to the concrete mixture, but it has been noted that an increase in the carbon content(LOI) of fly ash causes problems in proper air entrainment in concrete. In this study, the entrained air content of mortar with fly ash as an additive was considered according to the mix design as a type of AEA, adding amount of fly ash and AEA, and the elapsed time. Moreover, two different types of measurement were also tired for air content.

  • PDF

퇴비화 첨가제의 공기투과성에 대한 분석 (Effect On the Air Permeability of Composting Bulking Agent)

  • 김병태
    • 유기물자원화
    • /
    • 제20권3호
    • /
    • pp.71-82
    • /
    • 2012
  • 국내에서 퇴비화 첨가제로 주로 사용되는 재료로는 톱밥과 목편(woodchip)으로서, 이들 첨가제는 주로 적정 수분함량 및 C/N비의 조절에 주안점을 주고 사용되고 있다. 하지만 톱밥과 목편(woodchip)은 서로 상이한 물리적 특성을 나타내고 있으며, 첨가제의 공기투과성에 대한 연구는 활발히 이루어지지 못하고 있다. 본 연구에서는 퇴비화 첨가제로 주로 사용되고 있는 톱밥과 목편(woodchip)의 혼합비율에 따라 용적 밀도, 수분함량, 공기공극, 입자크기, 공기유속 등이 공기투과성에 미치는 영향을 파악하였다. 모든 첨가제에서 수분함량이 증가함에 따라 공기공극율은 감소하고 입자크기는 증가하였으며, 특히 목편의 혼합비율이 높아짐에 따라 이러한 효과는 더욱 증대되는 경향을 나타내었다. 공기공극율과 수분함량은 선형의 관계로서 공기투과성에 미치는 영향은 매우 유사하게 나타났다. 건조수분함량 0.25~0.43(d.b.)(습윤수분함량으로는 20~30%) 이후의 구간에서는 공기공극율이 낮아짐에도 불구하고 압력손실이 감소함으로써 공기투과성이 개선되는 현상을 보이고 있다. 특히 입자크기가 5 mm로 커질 때까지 압력손실은 지수적으로 감소하여 공기투과성이 현저히 개선되고 있다. 이는 수분함량 증가에 따라 미세입자가 입단화됨으로써 대공극이 증가하고 이에 따라 공기이동성이 원활해 졌기 때문으로 여겨진다. 따라서 첨가제의 입자크기가 공기공극율이나 수분함량에 비하여 공기투과성에 미치는 영향이 매우 높았으며, 퇴비화시에는 초기 입자크기를 5 mm 이상으로 조절하는 것이 적합하다.

수입 솔로몬산(産) 미이용(미利用) 수종(樹種)의 인공건조(人工乾燥)스케쥴 개발(開發) (Development of Kiln Drying Schedule of Lesser-Known Species Imported from Solomon)

  • 정희석;심재현
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권1호
    • /
    • pp.45-54
    • /
    • 1986
  • A study was conducted to determine the physical properties related to drying characteristics, the seasonal air drying curves and the kiln drying schedule for taun lumber imported and utilized. This kiln drying schedule was found by oven drying and developed by pilot testing of green lumber and partially air dried lumber. The results of this study were as follows; 1. Average green specific gravity and standard deviation of heartwood lumber were 0.60${\pm}$0.03 and those of sapwood lumber were 0.64${\pm}$0.02. 2. Radial shrinkage from green to air dry and from green to oven dry were 3.05 percent and 5.96 percent respectively, and tangential shrinkage from green to air dry and to oven dry were 5.49 percent and 8.74 percent respectively. 3. Drying time for 25mm thick green lumber (50 percent moisture content) air dried to 30 percent moisture content were 14 days in springtime. 6 days in summertime, and 12 days in autumntime, whereas for 50mm thick lumber in 36 days in springtime, 18 days in summertime, 38 days in autumntime. 4. Kiln drying schedules developed by oven drying were T8-B3 for 25mm thick lumber and T5-B2 for 50mm thick lumber. 5. Kiln drying curves of green 25mm and 50mm thick lumber were similar to those of partially air dried lumber from the level of 30 percent average moisture content. Green 25mm thick lumber (55.7 percent moisture content) was dried to 9.3 percent moisture content in 101.5 hours and green 50mm thick lumber (65.6 percent moisture content) was dried to 11.5 percent moisture content in 526 hours. 6. End checking for green 25mm thick lumber occured in 49.6 percent moisture content and reached maximum amount in 27.6 percent moisture content and closed in 15.8 percent moisture content. 7. End checking for green 50mm thick lumber and partially air dried lumber developed and reached maximum amount earlier then for 25mm thick lumber. 8. Final moisture content of surface layer for 50mm thick lumber was one half of that of core, and moisture content equalized in the lumber after nine days of room conditioning. 9. Casehardening for 50mm thick lumber was slight and was conditioned after nine days of room stroage. 10. Drying defects, such as end checking and surface checking, were not observed and the quality of dry lumber was first.

  • PDF