• Title/Summary/Keyword: Air container

Search Result 172, Processing Time 0.028 seconds

Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis (이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계)

  • Dong-Soo, Choi;Yong-Hoon, Kim;Jin-SE, Kim;Chun-Wan, Park;Hyun-Mo, Jung;Ghi-Seok, Kim;Jong-Min, Park
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

Studies on Production of High-Quality Cornus controversa Container Seedlings (층층나무 우량 용기묘 생산에 관한 연구)

  • 윤택승;홍성각
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.3
    • /
    • pp.28-33
    • /
    • 2002
  • This study was carried out to develop the technique for the production of high quality container seedlings of Comus controversa Hemsley. The seedlings were grown on the medium of peatmoss : perlite : vermiculite (1:1:1, v/v) in plastic net container and no-net plastic container as control for five months in the PE house. The seedlings grown in the plastic net container showed better root collar diameter growth, better development of long and fine roots, more increment of dry mass of roots and shoots than those grown in the no-net container. But the height growth of the seedlings in both container was similar. In particular the seedlings grown in plastic net container had no spiraling roots which were always observed in the control container seedlings. This result was induced by air-root pruning effect from the plastic net container.

  • PDF

Development of a Waterless Container Utilizing Thermoelectric Modules for Live Fish Transportation (열전소자를 이용한 활어 수송용 무수 컨테이너의 개발)

  • 윤태복;김남진;이재용;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.519-524
    • /
    • 2000
  • The purpose of this study is to develop a low temperature waterless container for live fish transportation which is economical and efficient The principle of the waterless transportation is that a live fish becomes asphyxial at about $5^{\circ}C$can survive without water for a long time. A low temperature waterless container is developed for this purpose, which utilizes thermoelectric modules for rather smaller and lighter cooling system with precise temperature control devise compared to the existing mechanical system. At first, we succeeded in making flounders alive in the waterless container for 24 hours. Also when flounders were transported in a round trip from Inchon to Pusan in the waterless container, carried in a car, they survived in the waterless container for over 21 hours.

  • PDF

An air flow resistance model for a pressure cooling system based on container stacking methods (차압예냉에서 청과물 상자의 적재방법에 따른 송풍저항 예측모델 개발)

  • Kim, Oui-Woung;Kim, Hoon;Han, Jae-Woong;Lee, Hyo-Jai
    • Food Science and Preservation
    • /
    • v.20 no.3
    • /
    • pp.289-295
    • /
    • 2013
  • The capacity of a pressure fan can be designed based on the air flow resistance of containers packed with fruits and vegetables in a pressure cooling system. This study was conducted to develop an air flow resistance model that was dependent on changes in the air flow rate and the method of stacking containers. The air flow resistance of a container packed with uniformly shaped balls was 1.5 times greater than the sum of the air flow resistance of a vacant container and that of a wire net container packed with only balls. In addition, the air flow resistance increased exponentially as the width of the stacks increased; however, the air flow resistance did not increase greatly as the length and height of the stacks increased, which indicates that the air flow resistance is primarily influenced by the width of the stack in the air flow direction. The air flow resistance in two lines of stacking was up to 17% less than that of the width of the stack. It was also possible to determine the air flow resistance using a function of the air flow resistance through a single container and develop a prediction model. A prediction model of air flow resistance that is dependent on the stacking method and the air flow resistance of a single container was developed.

Experimental Study of a High Efficiency Transport Refrigeration Container under Cooling and Defrosting Conditions (고효율 냉동 컨테이너의 냉각 및 제상 실험)

  • Mun, Je-Cheol;Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.277-281
    • /
    • 2008
  • This paper presents the development of a high efficiency transport refrigeration system for sliced-raw fish transportation. The refrigeration system is equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system). System performance and container operating conditions are analyzed during experimental investigation on a $3,225{\times}1,740{\times}1,640\;mm$ full-scale refrigerated container under cooling and defrosting conditions. The prototype system indicates better performance in terms of shorter cooling-down time, shorter defrost time and smaller fluctuations of refrigerated container's temperature.

  • PDF

Optimization of shielding to reduce cosmic radiation damage to packaged semiconductors during air transport using Monte Carlo simulation

  • Lee, Ju Hyuk;Kim, Hyun Nam;Jeong, Heon Yong;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1817-1825
    • /
    • 2020
  • Background: Cosmic ray-induced particles can lead to failure of semiconductors packaged for export during air transport. This work performed MCNP 6.2 simulations to optimize shielding against neutrons and protons induced by cosmic radiation Methods and materials: The energy spectra of protons and neutrons by incident angle at the flight altitude were determined using atmospheric cuboid model. Various candidates for the shielding materials and the geometry of the Unit Load Device Container were evaluated to determine the conditions that allow optimal shielding at all sides of the container. Results: It was found that neutrons and protons, at the flight altitude, generally travel with a downward trajectory especially for the particles with high energy. This indicated that the largest number of particles struck the top of the container. Furthermore, the simulation results showed that, among the materials tested, borated polyethylene and stainless steel were the most optimal shielding materials. The optimal shielding structure was also determined with the weight limit of the container in consideration. Conclusions: Under the determined optimal shielding conditions, a significantly reduced number of neutrons and protons reach the contents inside the container, which ultimately reduces the possibility of semiconductor failure during air transport.

A Study on Two Phase Heat Exchange of Plate Type PCM Container (판형 상변화 물질 용기의 2상 열교환 현상 연구)

  • Kim, S.H.;Cho, S.W.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.576-582
    • /
    • 1996
  • This work studies qualitative thermal characteristics of PCM cold storage medium container and its surrounding streams. Experimental parameters are initial PCM temperature and cold water flow rate. A mathematical modeling was establised to estimate temperature distribution and the cooling process. We found that the phase-change temperatures of PCM varies from 6 to $8^{\circ}C$ which is constant for other materials and that the dominant heat transfer resistance is that on the container side taking about 3/4 of the total resistance. The one dimensional mathematical model predicts experimental data quit well.

  • PDF

Research on Packaging and Palletization for Improving Distribution Efficiency of Exported Fresh Agricultural Products (신선농산물의 수출 포장개발 및 파렛트화에 관한 연구)

  • Lee, Soo-Keun;Lee, Myung-Hoon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.11 no.2
    • /
    • pp.75-79
    • /
    • 2005
  • With three kinds of agricultural products such as perilla leaves, this research is focussed on how to keep a freshness of agricultural products during long time transport by sea. In case of export fresh agricultural products by sea, research on products loading method onto the pallet is very important factor for keeping effective cold air circulation inside the freezing marine container. Details are as follows: Clear examination of palletization for cold air ventilation inside the container. Optimization of package dimension for best loading efficiency onto the standard pallet. Best layout of palletized products inside the container. Research for the change of circumstance and product quality inside the pack.

  • PDF

A Container Stacking System for the Mobile Harbor (모바일하버에 적용할 컨테이너 적재 유도 시스템)

  • Kim, In-Su;Kim, Kwang-Hoon;Son, Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.672-678
    • /
    • 2010
  • The purpose of this study is to develop a stacking guidance system (SGS) of containers in the mobile harbor (MH). A mobile harbor is a floating structure especially designed for loading and unloading containers from and to a large container ship. A novel stacking guidance system was proposed for unloading the container in an effective way against possible vibrations of the floating body. The guidance system works as an aid for loading containers with a wider opening for easier stacking of a container into a moving storage cell due to waves. In order to determine the most effective inclination angle of the cell-guide, this study performed the dynamic analysis of the SGS equipped in the MH subject to fluctuations of the sea. The motions of the guidance system and a container loaded were calculated using ADAMS. The simulation results of the contact force between the two rigid bodies showed that a desirable angle of the cell-guide should be around 20 degrees from the vertical. This proposed SGS can considerably reduce the loading and unloading time, and will enhance the performance of the MH.

Characteristics of Container Architecture Shown in Container Multiplex Cultural Space and User Satisfaction (컨테이너 복합문화공간에 나타난 컨테이너 건축특성과 이용자 만족도)

  • Kim, Hyun-Jin;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2018
  • This study is intended to suggest an improvement scheme of activating container multiplex cultural space through an analysis of container architecture characteristics and a survey of user satisfaction, focusing on container multiplex cultural space located in Seoul city. Hence, the elements of multiplex cultural space and the characteristics of container architecture were deduced and analyzed through precedent study and literature review relating to multiplex cultural space and container architecture, and then an analysis framework was established with items to measure the user satisfaction. Based on this, a questionnaire was created, and users were surveyed through on-site visit. The results of analyzing the container multiplex cultural space users' satisfaction are as follows. First, in order to increase user satisfaction, it is necessary to highlight visual element. Second, there is necessity for distinct space configuration, such as connection, stack and extension by utilizing the fixed specifications, the characteristics of container. Third, there is necessity for extended space where people feel a sense of openness. Fourth, it should be improved so that air is well circulated by installing glass, operable window, etc. In further research, it is thought necessary to make a study of commercial space and facilities inside university besides multiplex cultural space.