DOAS/CRCP 시스템 설계

  • Jeong, Jae-Weon
    • 대한설비공학회지:설비저널
    • /
    • 제35권12호
    • /
    • pp.41-48
    • /
    • 2006
  • For the Designing a Dedicated Outdoor Air System with Ceiling Radiant Cooling Panels the concept of a dedicated outdoor air system(DOAS) with parallel sensible cooling was born from the decoupled system concept, which can be summarized as decoupling of ventilation and air-conditioning functions, or decoupling of sensible and latent load functions. First , remove the latent loads from the outside air(OA) intake and generated in spaces using a 100% OA ventilation system(i.e., DOAS). Second, remove the space sensible loads using a parallel mechanical cooling system, such as fan coil units, conventional variable air volume , and ceiling radiant cooling panel(CRCP) independent of the ventilation system.

  • PDF

국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구 (A Study on the Facility Eligibility Inspection of National Inpatient Isolation Units)

  • 홍진관
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.506-514
    • /
    • 2015
  • During the progression of this study, we visited 17 medical institutions. These medical institutions underwent inspection for facility eligibility of national inpatient isolation units to care for patients. Seventeen consultation meetings were held to gather expert opinions, and conferences were held with the medical institutions and local levels of government. Based on these facts, we established a field application model of the criteria of safety-management and conducted a study on this method in order to create more scientific and systematic safety-management criteria including criteria regarding facilities maintenance and methods of equipment inspection. According to an analysis on the 17 medical institutions examined, facility eligibility of 17 national inpatient isolation units was found to be 78.3% on average. Through analysis of the present domestic and foreign conditions of medical institutions, we proposed improvements for when remodeling becomes necessary and established criteria for safety-management in national inpatient isolation units for the care of patients in accordance with the domestic healthcare system.

VAV 시스템의 현장 운전방식에 따른 에너지 성능평가 (Energy Performance Evaluation of VAV System through Various Operating Strategies in Office Buildings)

  • 서종욱;허정호
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.184-193
    • /
    • 2004
  • The purpose of this study is to evaluate the performance of various control strategies in commercial buildings which have been operated by the variable air volume (VAV) system. Two buildings in Seoul were chosen for the field study. The one (D building) combined by LonWorks has the constant airflow of supply fan and the proportional control of VAV units (damper type). The other (S building) combined by DDC has the PI control mode of the supply fan and the floating control of VAV units (venturi type). In estimating thermal comfort and energy performance through control modes of PI, PID, and CAV in the supply fan, we could identify several energy efficient operating control strategies for the VAV system.

천장형 에어컨 소음의 허용 음압레벨 도출 (Allowable sound pressure levels of ceiling mounted air-conditioning sounds)

  • 유진;정충일;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

차륜형 대공포 냉방장치 성능개선 연구 (Study on Improvement of Air Conditioning Units for Anti Aircraft Gun Wheeled Vehicle)

  • 전기현;이동희;이부환
    • 대한기계학회논문집B
    • /
    • 제37권12호
    • /
    • pp.1099-1103
    • /
    • 2013
  • 과거의 무기체계는 체계의 목적과 비용 등의 문제로 운용환경에 대한 관심이 부족하였으며, 특히 냉방장치가 미탑제된 체계가 많이 개발되었다. 근래 개발되는 무기체계는 고도의 정밀조준 및 고감도 시스템으로 진화함에 따라 무기체계를 효과적으로 제어하기 위하여 운용자의 운용환경도 중요한 요소로 대두되고 있다. 현재의 무기개발자들은 대부분 통합형 환경제어장치를 장착하도록 설계하고 있다. 본 연구에서는 장갑차량의 운용환경 및 설계조건을 바탕으로 한국군의 운용환경에 적합한 냉방기 및 냉방 부하를 검토하고 시제품의 냉방성능 시험결과가 목표성능에 미달되어 이에 대해 개선내용 및 검토결과를 기술하였다.

멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발 (Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner)

  • 박병덕;이주동;;황일남;장세동;정백영
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

에어콘의 효과적인 퍼지 제어 시스템의 설계 (The Design of Efficient Fuzzy Logic Control System for Air-Conditioner)

  • 김일;이상배;이철영
    • 한국항해학회지
    • /
    • 제18권4호
    • /
    • pp.147-154
    • /
    • 1994
  • A practical application of a fuzzy control system is described for an air-conditioning system. Air-hadling units are being widely used for improving the performance of central air-conditioning systems. The fuzzy control system has two controlled variables, temperature and humidity, and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical control, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy control system was described for controlling air-conditioning systems efficiently and economically.

  • PDF

퍼지 알고리즘을 이용한 시스템 에어컨의 냉매충전량 감지 프로그램 개발 (Program Development for Detecting Charged Refrigerant Amount in System Air-Conditioner using Fuzzy Algorithm)

  • 태상진;최창식;김훈모;조금남;문제명;김종엽;권형진
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.172-179
    • /
    • 2006
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in the system air-conditioner than in a general single air-conditioner. Experiments were performed for a 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The experimental amount of the charged refrigerant was ranged from $60\%\;to\;140\%\;with\;10\%$ increasement. Fuzzy algorithm was employed for detecting the charged refrigerant amount in the system air-conditioner. The experimental data were used for curve-fitting for the general ranges of indoor and outdoor temperature conditions. Membership function was determined for the whole ranges of experimentally measured data and rule-bases were defined for each charged refrigerant amount. Developed program successfully predicted the measured data within $10\%$ resolution range.

원심펌프 베어링 유닛의 열신뢰성 분석 (Thermal Reliability Analysis of the Bearing Units in a Centrifugal Pump)

  • 문정환;문승재;이재헌
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.313-320
    • /
    • 2007
  • In this paper, the experimental study has been carried out to investigate the reliability lifetime of two bearing units based on the oil temperature. Measurements for the oil temperature as well as the bearing temperature during normal operation were performed to study the effects of oil viscosity and oil submergence percentages in the two bearing units. The optimal lubrication condition to increase the lifetime of the bearing unit A was found that its viscosity and submergence percentage were VG32 and 25%, respectively. For the bearing unit B, when the oil viscosity and submergence percent were VG32 and 75%, the lubrication condition was the most efficient. Finally, the adjusted rating times of both the bearing units were calculated to be over 28,000 h, which is greater than the minimum adjusted rating times of 25,000 h. Therefore, they satisfied the regulated lifetime of API 610.

상변화 축열계의 비정상 해석 (A Study on Two Dimensional Phase Change Problem)

  • 원성필;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.12-21
    • /
    • 1981
  • The Enthalpy Model was verified in order to analyze two- dimensional phase change problems. By using the Enthalpy Model, interface locations, frozen fraction rates, heat flux distribution rut cooled surfaces, and surface-integrated heat flux were purely numerically calculated in rectangular thermal storage units, whose initial condition was saturated liquid and phase change material was cooled on its boundaries by convective heat transfer. The calculations were performed for various Stefan numbers and Biot numbers. The effect on those dimensionless numbers were explained.

  • PDF