• 제목/요약/키워드: Air conditioning odor

검색결과 16건 처리시간 0.028초

부분최소자승법을 이용한 중고차 에어컨냄새 원인물질 추정 (Estimation of VOCs Affecting a Used Car Air Conditioning Smell via PLSR)

  • 유한민;이태희;성기우
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.175-182
    • /
    • 2013
  • Lately, customers think highly of the emotional satisfaction and as a result, issues on odor are matters of concern. The cases are odor of interior material and air-conditioner of vehicles. In particualar, with respect to the odor of air-conditioner, customers strongly claimed defects with provocative comments : "It smells like something rotten," "It smells like a foot odor," "It stinks like a rag." Generally, it is known that mold of evaporator core in the air-conditioning system decays and this produce VOCs which causes the odor to occur. In this study, partial least squares regression model is applied to predict the strength of the odor and select of important VOCs which affect car air conditioning smell. The PLS method is basically a particular multilinear regression algorithm which can handle correlated inputs and limited data. The number of latent variable is determined by the point which is stabilized mean absolute deviations of VOCs data. Also multiple linear regression is carried out to confirm the validity of PLS method.

자원회수시설용 폐기물 벙커의 환기설비설계 개선에 관한 연구 (Improvement of the Ventilation Equipment in a Waste Bunker For a Municipal Waste Incinerator)

  • 이태구;문정환;허진혁;이재헌
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.51-59
    • /
    • 2007
  • The waste bunker usually consists of waste entrance zone and waste pit. In this paper, the distributions of air flow, $NH_3$ concentration and $H_2S$ concentration in a waste bunker were investigated to prevent an odor generated in a waste pit from dispersing to the waste entrance zone by numerical method. Four cases were considered such that 1) the waste incinerators is operated, 2) the waste incinerators is stopped, 3) the waste incinerator is operated and the direction of a supply diffuser is $45^{\circ}$ upward, 4) the waste incinerator is stopped and the direction of a supply diffuser is $45^{\circ}$ upward. In case of 1), the fresh air from the waste entrance zone is exhausted smoothly to the main exhaust grill of the waste pit. It means that an odor dispersion to the waste entrance zone will not occur. However in case of 2), the induction of fresh air is so small and the supply air with an odor in waste pit can flow to the waste entrance zone. Therefore, an odor will be dispersed to the waste entrance zone. This paper shows the solution that the supply diffuser with the direction of $45^{\circ}$ upward is chosen. As a result in case of 3) and 4), an odor dispersion to the waste entrance zone does not occurred and on odor is exhausted smoothly to the auxiliary exhaust grill.

은나노 소재를 이용한 공조기의 탈취 성능 향상에 관한 실험적 연구 (An Experimental Study on the Deodorization Performance Enhancement of the Air Handling Unit Using a Nano-Silver Material)

  • 남상엽;강병하;송지현;한성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.739-744
    • /
    • 2009
  • The filter has long been used in purification processes for indoor air quality. To determine the deodorization effect of several filter materials in a full-scale air-handling system, the present study has been carried out using a wind tunnel equipped with a heat exchanger and various filter materials, such as commercial fabric, activated carbon(AC) and silver nano-particles attached to activated carbon(Ag-AC). The experiment was conducted using an odor substance with ammonia, acetaldehyde, acetic acid. The results obtained indicate that odor substance is substantially decreased on the moisture condensation on the surface of the heat exchanger. The fabric filter has no effect for removal of odor substances. The deodorization efficiency is found to be approximately 7% in the AC filter, while the deodorization efficiency is increased up to 10% using the Ag-AC filter.

  • PDF

Intelligent Air Quality Sensor System with Back Propagation Neural Network in Automobile

  • Lee, Seung-Chul;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.468-471
    • /
    • 2005
  • The Air Quality Sensor(AQS), located near the fresh air inlet, serves to reduce the amount of pollution entering the vehicle cabin through the HVAC(heating, ventilating, and air conditioning) system by sending a signal to close the fresh air inlet door/ventilation flap when the vehicle enters a high pollution area. One chip sensor module which include above two sensing elements, humidity sensor and bad odor sensor was developed for AQS (air quality sensor) in automobile. With this sensor module, PIC microcontroller was designed with back propagation neural network to reduce detecting error when the motor vehicles pass through the dense fog area. The signal from neural network was modified to control the inlet of automobile and display the result or alarm the situation. One chip microcontroller, Atmega128L (ATmega Ltd., USA) was used. For the control and display. And our developed system can intelligently detect the bad odor when the motor vehicles pass through the polluted air zone such as cattle farm.

  • PDF

A Study on Ways to Improve the Smell of Pig Barn

  • Min-Jae JUNG;Su-Hye KIM;Young-Do KIM
    • 웰빙융합연구
    • /
    • 제6권2호
    • /
    • pp.9-13
    • /
    • 2023
  • Purpose: In this study, we would like to make a technical proposal to solve the odor problem in pig houses. Through this, we would like to suggest an effective way to reduce the odor generated in the pig house as a solution to civil complaints. Research design, data and methodology: Conduct direct visits to pig farms where many civil complaints about bad odor occur, and identify the problems of each farm. Identify elements related to odor control, such as structure, facility, equipment, odor management method, and ventilation type. Through this, the technology to be applied to reduce odor and the solution to the odor problem are presented. Results: The results of major improvements are as follows: 1. Improvement of the structure of the barn or composting shed to an airtight type 2. Improvement of the pig manure treatment structure using the slope inside the barn 3. Establishment of ventilation and cooling systems 4. Automation of the mist spray system. Conclusions: As a result, as practical measures, sealing of facilities using winch curtains, construction of air conditioning systems using negative pressure ventilation, and management systems using AIoT systems were presented. It is judged that this study can be helpful in determining the grievances caused by civil complaints of tenant livestock farms and the direction of facility improvement in the future.

응축수를 이용한 냉각기의 냄새원인물질 평가방법 검토 (Examination about evaluation method of odor active compounds in evaporator by using condensed water)

  • 김선화;김경환;정영림;김만구;김재호;박하영;지용준
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.361-369
    • /
    • 2007
  • 냉각기에서 방출되는 불쾌한 냄새는 실내 공기질을 저하시키는 주요 원인이다. 냄새문제를 해결하기 위해서는 냄새원인을 규명하여야 한다. 냉각기에서 냄새가 발생될 때 공기시료는 냄새강도는 약하고 순간적이어서 채취하여 분석하는데 많은 어려움이 따른다. 이 연구에서 응축수를 이용하여 냉각기의 냄새원인물질의 평가 가능성을 확인하였다. 응축수는 headspace-solidphase microextraction(HS-SPME) 방법을 이용하여 채취하였다. GC/FID/Olfactometry(GC/FID/O)로 냄새물질을 확인한 후, GC/AED, GC/MS로 정성하였다. 직접관능평가 결과 및 GC/FID/O의 개별냄새물질 분석 결과, 공기시료와 매우 유사하게 나타났다. 냄새원인물질은 주로 산소를 포함하는 alcohols와 acids로 확인되었다. 응축수를 이용한 냄새원인물질 평가 방법은 채취 용이성, 비용, 분석적인 측면에서 효과적인 방법으로 평가 되었다.

악취분별능력을 가진 자동차용 고기능 듀얼타입 집적형 유해가스 유입차단센서 개발 (Development of High Sensitive Integrated Dual Sensor to Detect Harmful Exhaust Gas and Odor for the Automotive)

  • 정완영;심창현
    • 제어로봇시스템학회논문지
    • /
    • 제13권7호
    • /
    • pp.616-623
    • /
    • 2007
  • A dual micro gas sensor array was fabricated using nano sized $SnO_2$ thin films which had good sensitivities to CO and combustible gases, or $H_2S$ gas for air quality sensors in automobile. The already existed air quality sensor detects oxidizing gases and reducing gases, the air quality sensor(AQS), located near the fresh air inlet detected the harmful gases, the fresh air inlet door/ventilation flap was closed to reduce the amount of pollution entering the vehicle cabin through HVAC(heating, ventilating, and air conditioning) system. In this study, to make $SnO_2$ thin film AQS sensor, thin tin metal layer between 1000 and $2000{\AA}$ thick was oxidized between 600 and $800^{\circ}C$ by thermal oxidation. The gas sensing layers such as $SnO_2$, $SnO_2$(pt) and $SnO_2$(+CuO) were patterned by metal shadow mask for simple fabrication process on the silicon substrate. The micro gas sensors with $SnO_2$(+Pt) and $SnO_2$(CuO) showed good selectivity to CO gas among reducing gases and good sensitivity to $H_2S$ that is main component of bad odor, separately.

열회수형 환기장치의 운전조건에 따른 경제성 평가에 관한 연구 (A Cost Analysis of the Heat Recovery Ventilator under Various Condition)

  • 강태욱;고재윤
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.21-28
    • /
    • 2006
  • Changes in building construction methods and repairing of older buildings have reduced infiltration rate. Synthetic materials, release airborne particles and uneven healthy odor are increased. For preventing pollutants introduce fresh outdoor air into the building, simply letting fresh outdoor air into building, however, Is not a cost-effective way to ventilation. When additional ventilation is added to an existing HVAC system, the heating and cooling equipment, often cannot handle the increased load. A HRV provides a way to minimize in energy costs while introducing fresh air to a building. In this study, the economical research of HRV, made of three types of materials, are conducted. Heat recovering characteristics are studied at seasonal outdoor air conditions based on the outdoor air property condition at, Seoul in 2002. As a results, the average sensible effectiveness is 0.75 in the sensible heat exchanger and average total effectiveness is 0.65 in the total heat exchanger. The pay back period of the sensible heat exchangers are $3.2{\sim}3.5$ year and it of total heat exchanger is 2.2 years.

화장실을 이용한 층별 피난공간 확보 기술개발 (Development of Technology to Secure Refuge Space by Using Existing Restroom)

  • 김지석;신현준;김정엽;박병직
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.24-30
    • /
    • 2015
  • The fire on a high-rise building would possibly cause fatalities because of ineffective egress due to extended evacuation distance in huge building structure, coupled with dense population, thus requiring secured optimal evacuation method and space. The restroom located in the living space is considered to be useful refuge space which is built with wet pipe and noncombustible materials. This study aimed to develop a system that would make use of the existing restroom as a fire refuge space. Ventilation duct were installed to discharge odor during normal conditions. We could serve the air supply duct to also raise the air pressure in the restroom so as to prevent the toxic gas from gapping around the restroom. The nozzle for the water screen would be installed in restroom door facing the living room to form the water screen which would protect the door. This study is intended to replace the existing refuge space with the restroom in such a way as described above.