태양열 이용 냉난방 공조시스템 중 전열교환기의 최적운전조건에 관한 연구 (Research on the Optimal Operating Condition of a Total Heat Exchanger in Solar Air-Conditioning System)

  • 김광호;최광환;금종수;김보철;김동규
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.55-62
    • /
    • 1999
  • This study was performed to find out the influence of experimental factors on dehumidification performance and furthermore to suggest an optimal combination of factors of a total heat exchanger in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where the temperature and humidity was maintained constant. In order to find out the contribution ratio of factors on dehumidification performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, the most influential factor on dehumidification performance was the concentration of LiCl(Lithium Chloride) solution. The next influential factors were the temperature of LiCl solution and the air flow rate. The packed layer height, packed material, and flow rate of LiCl solution had no influence on the dehumidification performance under these experimental conditions. Through the three level experiments of $L_{27}(3^{13})$, it was found that the optimal combination was $A_2B_0G_2$(concentration of solution 30 wt%, temperature of solution $15^{\circ}C$, air flow rate $253m^3/h$).

  • PDF

학교교실의 냉방시 실내열.공기환경 실태 (Present Condition of Indoor Thermal and Air Environment by Cooling in School Classrooms)

  • 최윤정;정연홍;이선아;김혜경;황진아
    • 한국주거학회논문집
    • /
    • 제18권4호
    • /
    • pp.49-58
    • /
    • 2007
  • The purpose of this study were to make clear the present condition of indoor thermal and air environment by cooling in school classrooms and to analyze the relation of the living conditions with indoor environment. The measurements on physical elements and observations on living conditions were carried out in 6 classrooms of 3 middle or high schools. Measuring elements were indoor temperature, relative humidity, PM10 and $CO_2$ concentration. As results, the averages of indoor temperature each classrooms were $24.9{\sim}26.6^{\circ}C$. Most of classrooms were lower than the Maintenance standard $(26{\sim}28^{\circ}C)$ of School Health Law. The means of relative humidity were $51.3{\sim}72%$, all classrooms were ranged within the standard $(30{\sim}80%)$. The means of PM10 concentration were $3.5{\sim}23.1{\mu}g/m^3$, all classrooms were kept within the standard $(100{\mu}g/m^3)$. The means of $CO_2$ concentration were $1218.7{\sim}4705.4ppm$, all classrooms were exceed the standard (1,000ppm). The results of analysis on relations of living conditions with the physical elements are as follow; the air conditioner set of temperature, windows and doors opening elapsed time, the number of students in classrooms and activities of students had certain effect on indoor environment.

PC-ECU를 이용한 SI 기관의 비정상상태 정밀공연비 제어 (Precise Air-Fuel Ratio Control on Transient Conditions with the PC-ECU in SI Engine)

  • 윤수한
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.9-16
    • /
    • 2000
  • In a SI engine, three-way catalyst converter has the best efficiency when A/F ratio is near the stoichiometry. The feedback control using oxygen sensors in the commercial engine has limits caused by the system delays. So it is necessary to control fuel quantity in accordance with intake air amount in order to reduce exhaust emission and improve the specific fuel consumption. Precise A/F ratio control requires measurement of air amount with respect to the cylinder and injection fuel according to the air amount In this paper, we applied nonlinear fuel injection model and developed the algorithm of A/F ratio control. This algorithm includes the methods of measurement of transient air mass flowing into each cylinder, of calculation of injection pulse width for measured air mass, and the method of feedback and engine control by using lambda sensor. Also we developed control program for IBM-PC by using C++ Builder, and tested it in the commercial engine.

  • PDF

여름철 냉방실내의 적정착의량에 관한 연구 (A Study on the Optimal Clothing Weight in an Air Conditioned Office in Summer)

  • 김선영;이순원
    • 한국의류학회지
    • /
    • 제9권3호
    • /
    • pp.45-51
    • /
    • 1985
  • The purpose of this study is to research into the thermal condition and the weight of clothes suitable for the officers engagged in light works in an air-conditioned room in summer. The Major findings are as follows: 1. Thermal conditions of the working environment are $24.5^{\circ}C$ (Dry bulb temp.), $68\%$ (Relative humidity) and 2.6m/sec (Air Velocity). 2. Total clothing weights are 416.6 g/$m^2$ (male) and 340.9 g/$m^2$ (female). Underwear weights are 96.8g/$m^2$ (male) and 85.1g/$m^2$ (female). The latter turned out to be statistically significant in Sexual difference. 3. Means of the thermal sensation are 3.0 (comfortable; male) 2.7 ('Slightly cool' -'Comfortable'; female) and the relationship between clothing weights and thermal sensation proves to be significantly correlated in the case of female. 4. $66.7\%$ of the women and $37.1\%$ of the men feel sensation of coldness at the body's specific area and $79.5\%$ of the women and $54.3\%$ of the men reveals air-conditioning disturbance. 5. As the thermal sensation is close to 'cool-cold', sensation of coldness or air conditioning disturbance are showed up more frequently which is reversely related with weight of under-wear. It is also proved that air conditioning disturbances are influenced by sexual difference in addition to sensation of coldness and thermal sensation. 6. According to the result of experiment, we can have the idea that at condition $X_1$, the drop of limbs' skin temp. is remarkable. At condition $X_2$ skin temp. for distal limbs and mean skin temp. are raised and the falling degree is similar. At condition $X_3$, mean skin temp. and distal skin temp. are remarkably raised, and the falling degree decreases and the beats of pulse rate increase and diastoric blood pressure is lowered.

  • PDF

Air-lift Fermenter System을 이용한 Ganoderma lucidum 균사체의 심부배양에 의한 세포외 다당류의 생산 조건 (Condition of Exo-polysacchride Production from Submerged Mycelial Culture of Ganoderma lucidum by Using Air-lift Fermenter System)

  • 이신영;강태수;이만춘
    • KSBB Journal
    • /
    • 제13권5호
    • /
    • pp.547-553
    • /
    • 1998
  • For the efficient production of a new exo-polysaccharide from Ganoderma lucidum ASI 7004, the optimum conditions and methods in submerged cultivation were investigated with an airlift fermenter system. The optimum aeration rate was 2.5 Wm at the initial pH 5.0 and 28$^{\circ}C$. The increase of dissolved oxygen concentration by pure oxygen supply during cultivation did not improved the exo-polysaccaride production and the mycelial growth. The maximum exo-polysaccharide production and the mycelial growth under the optimum culture condition were obtained in media of glucose 60g/L, yeast extract 6g/L, (NH4)2HPO4 1g/L and KH2PO4 0.5g/L. Under these optimum medium and culture conditions, about 7.15g/L of exo-polysaccharide and 13.9g/L of mycelial growth were producted, respectively.

  • PDF

공동주택의 여름철 수용 쾌적온도 범위와 거주자의 냉방기 사용행위에 관한 연구 (A Study on Acceptable Thermal Comfort Zone and Resident Behavior of Operating Cooling Devices in Apartments)

  • 전정윤;배누리
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.477-486
    • /
    • 2005
  • In this study, indoor thermal environment, resident behavior of operating cooling device, and thermal comfort vote are investigated at the living room of apartment during summertime in Seoul. Based on the results of the investigation, indoor air temperatures that residents turn air conditioners (especially for cooling load in this research) on and off were found out. The relationships between outdoor weather condition and the number of days using air conditioner, and whether operating patterns of the devices were also found out. The acceptable thermal comfort zone is figured out from these results, and this research is expected to contribute to the development of household air conditioner. The results can be summarized as the followings; Residents turned the air conditioner on at $29.76^{\circ}C$ of indoor air temperature, and $28.89^{\circ}C$ of $SET^\ast$. And turned the air conditioner off at $27.31^{\circ}C$ of indoor air temperature, and $23.70^{\circ}C$ $SET^\ast$. Therefore, acceptable thermal comfort zone could be lied between these temperatures. If comfortable indoor thermal environment can be obtained with various architectural passive cooling techniques based on the results, energy consumption of cooling devices will be reduced.

수직원통형 빙축열조내 외향용융과정시 열전달특성에 관한 연구 -작동유체의 유동방향 및 축열조 형상비에 따른 열성능 비교- (A study on the heat transfer characteristics during outward melting process of ice in a vertical cylinder)

  • 김동환;김동춘;김일경;김영기;임장순
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.171-179
    • /
    • 1997
  • During the day time in summer, peak of air conditing load, and electric power management system lies under overloaded condition. The reason is the enlarged peak load value of electric power caused by increased air-cooling load in summer. To prevent load concentration during day time and overloaded condition of power management system, some energy storage methods are suggested. One of these methods is ice storage system. Water has some good properties as P.C.M.(Phase Chang Material) : Its melting point is the range of required operation temperature. It has large specific latent heat and is chemically stable compared to other organic or inorganic substances. It is cheap and easy to treat. This study represents experimental results of heat transfer characteristics of P.C.M. under the outward melting process in a vertical cylinder. We experimented with twelve combinations of conditions, i.e., three different inlet temperatures($7^{\circ}C,\;4^{\circ}C\;and\;1^{\circ}C$), two working fluid directions(upward and downward), and two aspect ratios, H/R(4 and 2). At the inlet temperature of $7^{\circ}C$ and $4^{\circ}C$, there was temperature stagnation region where the temperature of P.C.M. remains constant at $4^{\circ}C$ regardless of aspect ratio and direction of working fluid. This temperature stagnation occurs as the water, at its maximum density, flows down to the lower region. The phase change interface formed bell-shaped curve as the melting process continued. With a new set of conditions(4H/R, inlet temperature $4^{\circ}C$ and $1^{\circ}C$, downward/upwerd inlet direction), the movement of phase change interface was faster when the working flued inlet direction was downward. With the same set of conditions, melting rate and total melting energy were larger when the working fluid inlet direction was downward. The results were reversed when the other sets of conditions were applied.

  • PDF

장방형 공간내 난류유동및 오염물질 거동의 수치해석 (A Numerical Analysis of Turbulent Flow Field and Contamination Particles Movements in Rectangular Chambers)

  • 심우섭;송기천;황태연;신영철
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.350-364
    • /
    • 1991
  • The movements of small particles distributed uniformly in a steady flow in rectangular chambers having inlets and outlets were simulated numerically. Low Reynolds number turbulent model with a two-equation ($k-{\varepsilon}$) which describes the turbulent characteristics was applied to predict the air flow pattern and particles movements under the condition of the various locations and size of ducts. The calculation results show that the prediction of recirculation zone and stagnation point of flow is important to determine the particles behavior according to the design change. These results will be useful in designing the rectangular chambers for collective protection.

  • PDF

자연급기 무가습 연료전지의 Dry-out조건 (Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas)

  • 박상균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

시설원예 습도환경 제어를 위한 냉각식 제습기 개발 (Development of a Refrigeratory-Based Dehumidifier for Humidity Environment Control in Greenhouse)

  • 강금춘;연광석;유영선;김영중;강연구;백이
    • Journal of Biosystems Engineering
    • /
    • 제32권4호
    • /
    • pp.247-255
    • /
    • 2007
  • During the winter season in Korea, the relative humidity of greenhouse at night often exceeds 90% because air temperature inside the greenhouse is usually controlled using a heater with all of windows closed to minimize heat loss, thereby requiring the use of a dehumidifier that can maintain optimum humidity levels of $70{\sim}80%$ to provide a good growth condition of crops. Also, such a high humid condition can cause the development of a pest, such as insects, fungi or diseases. However, the use of most conventional dehumidifiers for low temperature dehumidification is limited because their performance is degraded due to frost accumulation on the evaporator coil. This study was carried out to develop a refrigeratory-based dehumidifier suitable for low temperature dehumidification in greenhouse cultivation. The developed dehumidifier consists of a condenser and an evaporator installed separately so that relative and absolute humidity levels can be reduced when air passed through the condenser and evaporator, respectively. The prototype dehumidifier showed a dehumidification capacity of $5{\sim}7kg/h$ when air with a temperature of $15{\sim}25^{\circ}C$ and a relative humidity of $70{\sim}95%$ came into the dehumidifier. Under the condition that either temperature or relative humidity was fixed, the amount of condensed water was proportional to the levels of both temperature and relative humidity.