• Title/Summary/Keyword: Air condition(A/C)

Search Result 922, Processing Time 0.029 seconds

A Study on Tribological Characteristics of Powder Sintered Fe-base Alloy (SMF9060) (Fe계 합금 분말 소결품(SMF9060)의 마모 특성 연구)

  • Kim, Sang Youn;Kim, Dae Wook;Park, Yeong Min;Shin, Dong Chul;Kim, Tae Gyu
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.27 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • SMF9060 material is a Fe-based powder sintered alloy that is used for several automobile components such as Synchronize Hub, oil pump and transmission. These components are required excellent wear resistance and durability. In this study, we have performed a dry wear test at the ambient air and Ar gas conditions in the room temperature, and a lubricant wear test at the room temperature and engine oil temperature of $100^{\circ}C$. The amount of wear volume and coefficient friction are measured by a Profilometer and a Ball on disk type wear tester. The wear volume in Ar gas condition was a little higher than that in the ambient air condition. However the wear volume in the lubricant wear condition was much lower than in the dry wear condition. XRD analysis of the debris in Ar gas condition showed that the oxide film was not formed.

Optimization of the Cold-air-drying Condition for a Steamed Pumpkin-Sweet Potato Slab (증절간 호박고구마의 냉풍건조조건 최적화)

  • Shin, Mi-Young;Lee, Won-Young
    • Food Science and Preservation
    • /
    • v.18 no.4
    • /
    • pp.488-496
    • /
    • 2011
  • Cold-air drying was conducted for a steamed pumpkin-sweet potato slab to improve its quality, convenience, and preference as a snack. A steamed pumpkin-sweet potato slab was dried from 10 to $25^{\circ}C$ for 48 h, and its moisture content, color, texture, and taste at different drying temperatures and drying times were evaluated. The lowest moisture content was 4.98%, at $25^{\circ}C$. The lightness decreased, but the other color values (a, b, and ${\Delta}E$) increased with the increasing drying temperature and drying time. The reducing sugar and soluble solid ranged from 98.7 to 194.75 mg/g and 19-70 $^{\circ}Brix$, respectively. The highest hardness of the steamed pumpkin-sweet potato slab was 23.88 $kg_f/cm^2$, and the springiness and cohesiveness were 91.15 and 98.36% when it was dried at $25^{\circ}C$ for 48 h. The sensory evaluation score was high at $10^{\circ}C$, 40 h and at $25^{\circ}C$, 24 h. The optimum drying condition was predicted at $19^{\circ}C$, 32 h via response surface methodology (RSM).

Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition (태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토)

  • Her, Jae-Young;Lee, Sang-Yong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF

Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser (응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험)

  • 김창덕;박일환;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.

A Study on the Influence Affect of Thermal Sensation in Korean and Japanes to Sit Directly on a Heated Floor (바닥난방시 바닥 접촉면에 의한 한국인과 일본인의 온열감 반응에 대한 비교 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2002
  • The objective of this paper is to clarify the combined effect of heat conduction, air temperature and thermal radiation on the person seated on the floor under operation of floor heating system. Experiments were conducted for summer seasons under 8 kinds of condition: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$ and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$ under still air. Japanese and Koreans were adopted as subjects. To evaluate the effect of conduction operative temperature modified by heat conduction was derived from the human heat balance equation. New weighting coefficients were estimated from the modified operative temperature and modified mean skin temperature. As for thermal sensation the modified operative temperature more significantly correlated to that sensation each heat transfer processes. As the floor temperature is higher, the human conduction heat gain from floor increase and the dry heat from the human body decrease.

  • PDF

A Survey on the Sanitary Condition of Kitchens in School Food-service Programs (일부 학교급식소 조리실의 위생관리에 관한 조사연구)

  • 김종규
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.87-93
    • /
    • 2003
  • A survey including an inspection was conducted to assess the sanitary condition of kitchens in the school food-service programs and to prepare background data for improving the safety of school meals. The survey was carried out over a two-month period (September-October, 2001). A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools in one region of Korea about food, sanitation, and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during preparation, cooking, and service. The inspection results showed their sanitary rendition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4~22.4$^{\circ}C$. and the range of relative humidity was 62.4~69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22..5 to 26.5 CFU/15 minutes. Although the results of inspection show that the levels of sanitary condition of kitchens in the schools were good, they are not satisfactory for safe food-servile because the temperature and humidity levels are high. This study indicates that the school kitchens should be monitored and strict inspection is necessary. The legal standards for school food-service should include standards for kitchen air temperature, relative humidity, and airborne microbes.

Study on the performance of a heat pump system with serial dehumidification function (직렬 제습방식 열펌프 시스템의 성능특성에 관한 연구)

  • Ko, Wonbin;Ko, Ji-Woon;Park, Youn Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.609-614
    • /
    • 2014
  • In this research, results of measuring temperature and relative humidity of underground-air-heat in Jeju showed $15{\sim}18^{\circ}C$ and 70~80% each which are somewhat high compare to other regions. So the Multi-effect dehumidifying and heating Heat Pump system which has merged functions of dehumidification and heating is made to solve this problem mentioned previously. When the suction air was $15^{\circ}C$ with 60% humidity, the outcome was 1.70 on $COP_h$ and 1.797(kg/h) on total amount of dehumidification, and also showed 1.87 $COP_h$ with 1.87 total amount of dehumidification under the condition of $20^{\circ}C$ and 80% humidity of suction air. Furthermore, $COP_h$ showed increased number which is 1.87 and also total amount of dehumidification increased which was 3.269(kg/h). The highest COP can be achieved at $17^{\circ}C$ and 70% relative humidity condition.

Cooling Performance of a Counterflow Regenerative Evaporative Cooler with Finned Channels (대향류 핀삽입형 재생증발식 냉방기의 냉방성능)

  • Moon, Hyun-Ki;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.462-469
    • /
    • 2008
  • A regenerative evaporative cooler has been fabricated and tested for the evaluation of cooling performance. The regenerative evaporative cooler is a kind of indirect evaporative cooler comprised of multiple pairs of dry and wet channels. The air flowing through the dry channels is cooled without any change in the humidity and at the outlet of the dry channel a part of air is redirected to the wet channel where the evaporative cooling takes place. The regenerative evaporative cooler fabricated in this study consists of the multiple pairs of finned channels in counterflow arrangement. The fins and heat transfer plates were made of aluminum and brazed for good thermal connection. Thin porous layer coating was applied to the internal surface of the wet channel to improve surface wettability. The regenerative evaporative cooler was placed in a climate chamber and tested at various operation condition. The cooling performance is found greatly influenced by the evaporation water flow rate. To improve the cooling performance, the evaporation water flow rate needs to be minimized as far as the even distribution of the evaporation water is secured. At the inlet condition of $32^{\circ}C$ and 50%RH, the outlet temperature was measured at $22^{\circ}C$ which is well below the inlet wet-bulb temperature of $23.7^{\circ}C$.

A Study on the Heat Transfer Enhancement by Trapezoid Rod in Impinging Jet System (충돌분류계에서 사다리형 로드를 이용한 열전달증진에 관한 연구)

  • Lim, T.S.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.565-571
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of air flow and heat transfer caused by trapezoid rods array in impinging air jet system. In this study, trapezoid rods have been set up on front of flat plate to act as a turbulence promoter. Local Nusselt numbers were determined as a function of three parameters: (a) the space from rods to heating surface(C=1, 2, 4mm), (b) the pitch between each rods(P=30, 40, 50mm), (c) the distance from nozzle exit to flat plate(H/B=2, 6, 10). And this research compared the above with the experiment without trapezoid rods. As a result, heat transfer performance was best under the condition of C=1mm and as the pitch is 30mm. In this case, maximum rate of heat transfer augmentation is about 1.9 times greater compared to that without trapezoid rods.

  • PDF

A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode (비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교)

  • Kim, Yong-Ki;Lee, Tae-Won;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF