• 제목/요약/키워드: Air cleaning unit

검색결과 33건 처리시간 0.024초

Numerical Analysis of Axial-Flow Cyclone Separator for Subway Station HVAC System Pre-Filter

  • Kim, Myung-Joon;Kim, Ho-Joong;Kwon, Soon-Bark;Kim, Se-Young;Kim, Jin-Kwan;Shin, Chang-Hun;Bae, Sung-Joon;Hwang, Sun-Ho;Kim, Tae-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.94-99
    • /
    • 2009
  • In the Korean subway station, three types of pre-filters, which include auto filter, electrostatic precipitator (ESP) and auto cleaning demister, are widely used. However, these devices have some problems such as the difficulty of maintenance and high operating cost. In this study, axial-flow cyclone separator was employed as a pre-filter inside a heating, ventilation, and air conditioning (HVAC) system. 3-dimensional computational fluid dynamics (CFD) analysis was performed on a single unit axial-flow cyclone and coupled unit axial-flow cyclone. Calculated and measured pressure drop of the designed axial-flow cyclone were found be comparable to other types of pre-filters and the observed cut-off diameter was less than 10 micron. Considering lower operating and maintenance cost, axial-flow cyclone was proved to be a better solution as a pre-filter.

실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System)

  • 구정환;김성찬;김장우;이주용;이재근;강태욱;이감규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Performance evaluation of TEDA impregnated activated carbon under long term operation simulated NPP operating condition

  • Lee, Hyun Chul;Lee, Doo Yong;Kim, Hak Soo;Kim, Cho Rong
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2652-2659
    • /
    • 2020
  • The methyl iodide (CH3I) removal performance of tri-ethylene-di-amine impregnated activated carbon (TEDA-AC) used in the air cleaning unit of nuclear power plants (NPPs) should be maintained at least 99% between 24 month-performance test period. In order for evaluating the effectiveness of TEDA-AC on the removal performance of CH3I in nuclear power plant during the operation of NPPs, the long-term test for up to 15 months was carried out under the simulated operating conditions (e.g., 25 ℃, RH 50%, ppb level poisoning gases injection) at nuclear power plants (NPPs). The TEDA-AC samples were analyzed with the Brunauer-Emmett-Teller (BET) specific surface area and TEDA content as well as CH3I penetration test. It is clearly evident that more than 99% of CH3I removal performance of TEDA-AC was observed in the TEDA-AC samples during 15 months of long-term operation under the simulated NPP operating conditions including the ppb level of organic and oxide form of poisoning gases. BET specific surface area and TEDA content that can affect the CH3I removal performance of TEDA-AC were also maintained as those in new TEDA-AC during 15 months of long-term operation.

종합병원의 환기설비 사례 연구 (A Case Study on the Ventilation System of the General hospital)

  • 정종림
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.

세탁과 건조에 따른 양모 위편성물의 편성조직별 형태 변화 (The effects of knit stitches on the knit construction and the dimensional stability to washing and drying of wool weft-knitted fabrics)

  • 박세은;백성필;박명자
    • 한국의상디자인학회지
    • /
    • 제24권2호
    • /
    • pp.1-10
    • /
    • 2022
  • The purpose of this study is to analyze the structural properties of 100% wool fabrics knitted with various stitch types and to evaluate dimensional stability from shrinkage in wet cleaning and drying. Materials were weft-knitted from twenty-four different stitches with 7 gauge using a computerized flatbed knitting machine. Weight, thickness, density, and length were measured. A domestic washing machine and a tumble dryer were used for the shrinkage test. The results are as follows: Knitted fabrics were divided into 3 groups based on weight per unit area. Porous knits show light weight whilst milano, pintuck, rib stitches belong to the heaviest group. A positive correlation between weight and thickness was found and the same result was obtained for wale density and weight. Dimensional shrinkage of knitted fabrics was increased during repetitive wet cleaning and drying regardless of knit stitches. Especially, fabrics knitted with float, tuck, cable, and links & links stitches samples were contracted more than 15% in the first treatment whereas 2x1 rib stitch showed 1% shrinkage rate. Fisherman and milano stitches contracted in both course and wale direction with similar shrinkage rates. However, porous knits with float and tuck stitches shrank in course direction by 20% as well as cable samples contracted from 5% to 20% after repeated washing and drying. On the other hand, 30% and 15% contraction of wale direction occurred in orderly float and links & links stitches, respectively. Machine dried knits have a higher shrinkage rate than air-dried knits, but the drying method did not affect to the direction of contraction. In conclusion, variations of knit, tuck, and float stitches affect knit construction and dimensional stability from shrinkage in wet cleaning and drying of wool knitted fabrics.

실내 공기질 개선을 위한 ICT 융복합형 플라즈마 폐열 환기 시스템 (ICT Fusion Type Plasma Waste Heat Ventilation System for Improvement of Indoor Air Quality)

  • 김응곤
    • 한국전자통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1215-1220
    • /
    • 2019
  • 현재 구제역의 발생과 AI로 인한 손해를 모두 본 부담하고 있다. 또한 축산업에서 악취에 대한 민원은 끊임없이 제기되고 있으며 앞으로 더 발생할 것으로 판단되고 있다. 본 논문에서는 축사 및 계사, 돈사 등과 같은 밀폐형 시설물들의 실내 공기질을 개선하고 질병 등을 예방하여 농가의 소득을 증대 시키는 것에 목적을 두었다. 환기 유닛 자리에 설치할 저온 플라즈마 폐열 환기 장치를 개발하고 내부에 넣을 열 교환 소자 및 저온 플라즈마 램프, 밸러스트를 규격화 하여 강화된 공기청정 기능을 갖도록 하였다. 또한, ICT를 접목하여 기존의 기상 시스템, 유동팬, 기타 시설 장비들과의 연동이 가능하고 농가들로 하여금 실시간으로 모니터링이 되도록 새로운 통제 시스템을 개발하고자 한다.

경유차 매연저감장치에 의해 비활성화된 DOC촉매의 재제조 효과에 관한 연구 (A Study on the Effectiveness of Remanufacturing Technology for the Diesel Oxidation Catalyst(DOC) Deactivated by Diesel Exhaust Gas)

  • 박해경
    • 청정기술
    • /
    • 제16권4호
    • /
    • pp.265-271
    • /
    • 2010
  • 경유차 매연저감장치에서 비활성화된 디젤산화촉매(DOC)를 대상으로 여러 가지 조건에서 재제조한 후, 재제조된 DOC의 일산화탄소(CO)와 탄화수소화합물(THC)의 저감효율과 촉매물성 특성을 분석하여 비활성화된 DOC 촉매에 대한 재제조 효과를 관찰하였다. 재제조된 DOC촉매에 대한 오염물질 저감성능 평가는 디젤엔진 다이나모 장치를 이용, 배기가스를 일부 우회시켜 온도와 공간속도조절이 가능한 촉매반응장치로 수행하였으며, 촉매물성 분석은 광학현미경, EDX, ICP, TGA 그리고 porosimeter를 이용하였다. 연구수행 결과 비활성화된 DOC 촉매를 본 연구에서 적용된 고온배소세정, 산성/염기성용액에 의한 초음파세정, 세정 후 촉매활성성분 재함침에 의한 재제조를 수행할 경우, 재제조된 DOC 촉매의 성능이 신품 성능의 90% 이상으로 회복되는 것을 확인하였으며, 광학현미경, EDX, TGA와 ICP등의 분석을 통해 본 연구조건에서의 재제조 과정으로, 촉매의 활성 저하 원인이 되었던 각종 불순 성분 대부분이 비활성화된 DOC 촉매로부터 제거되는 것을 확인하였다.

윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall)

  • 오인환;김운걸;이한성
    • 한국축산시설환경학회지
    • /
    • 제14권2호
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer)

  • 오인환;이종현;이경훈;이정훈;이동섭;어성만;이미림
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

집진기의 공기소모량과 백 필터내의 압력전파에 대한 실험적 연구 (Experimental Investigation on Air Consumption and Pressure Wave Propagation inside A Filter Bag of A Dust Collector)

  • 정원락;홍성철
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.886-891
    • /
    • 2008
  • 이 연구는 필터 백을 사용하는 집진기에서 펄스밸브에 부착된 솔레노이드 밸브의 통전 시간과 공기소모량 사이의 관계를 실험적으로 규명하였으며 이 때 필터 백에 작용하는 압력파의 전달과정을 고찰하였다. 펄스당 공기소 모량이 집진기 운전비용의 주요 요소이므로 펄스제트의 전파과정을 관찰하고 압력파형과 공기소모량을 측정하였다. 또 주어진 조건하에서 필터 백의 길이의 영향을 고찰하고 효율적인 탈진작용을 할 수 있는 통전시간과 충격량 사이의 관계를 규명하였다 주어진 실험조건 범위에서는 통전시간이 짧을수록 더 큰 충격량을 얻을 수 있으며 동일한 통전 시간에 대하여는 여러 번의 짧은 펄스를 발생시키는 것이 더 효율적인 것으로 나타났다.