• Title/Summary/Keyword: Air clean system

Search Result 289, Processing Time 0.03 seconds

Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method (베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법)

  • Choi, Hun;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.

Characteristics Analysis of a Direct-Drive AFPM Generator for 5kW Wind Turbine (직접 구동용 5kW AFPM 풍력 발전기 특성 해석)

  • Kim, Hyoung-Gil;Kim, Chul-Ho;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.773-774
    • /
    • 2006
  • Nowadays, the global interests are concentrated on the preserving of the clean environment, and the diminishing of the dependence on the fossil energy, and among the possible alternative energies, the wind turbine generating system is considered to be the best suited to produce high efficiency energy, without affecting the natural environment. The permanent magnet generators were been used for the wind power generating, for long time, with continuous efforts to improve the generating efficiency. And the latest trend on it is to develop an AFPM(Axial Flux Permanent Magnet)type, which is composed in the structure of rotor and stator shaped in the disc forms, and the direction of the flux at the air gap runs in parallel to the shaft. This thesis is on the study concerning with the analysis of the characteristics of the 5 kW at 300rpm direct drive AFPM generator which is suitable for the small scale wind turbine generating system. In it, the Electro-magnetically Coreless AFPM was been analyzed, the prototype generators been made, concentrated on interpreting the characteristics of the power output, and verifying it through the theoretical study and practical tests.

  • PDF

Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles (초미세입자 제거를 위한 나노세라믹 필터의 성능 평가)

  • Kim, Jong-Won;Ahn, Young-Chull;Yi, Byeong-Kwon;Jeong, Hyeon-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

PM2.5 Simulations for the Seoul Metropolitan Area: ( I ) Contributions of Precursor Emissions in the 2013 CAPSS Emissions Inventory (수도권 초미세먼지 농도모사: ( I ) 2013 CAPSS 배출량 목록의 전구물질별 기여도 추정)

  • Kim, Soontae;Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.2
    • /
    • pp.139-158
    • /
    • 2017
  • CMAQ (Community Multiscale Air Quality Model) simulations were carried out to estimate the potential range of contributions on surface $PM_{2.5}$ concentrations over the Seoul Metropolitan Area (SMA) with the gaseous precursors and Primary Particulate Matters(PPM) available from a recent national emissions inventory. In detail, on top of a base simulation utilizing the 2013 Clean Air Policy Supporting System (CAPSS) emission inventory, a set of Brute Force Method (BFM) simulations after reducing anthropogenic $NO_x$, $SO_2$, $NH_3$, VOCs, and PPM emissions released from area, mobile, and point sources in SMA by 50% were performed in turn. Modeling results show that zero-out contributions(ZOC) of $NH_3$ and PPM emissions from SMA are as high as $4{\sim}5{\mu}g/m^3$ over the region during the modeling period. On the contrary, ZOC of local $NO_x$ and $SO_2$ emissions to SMA $PM_{2.5}$ are less than $1{\mu}g/m^3$. Moreover, model analyses indicate that a wintertime $NO_x$ reduction at least up to 50% increases SMA $PM_{2.5}$ concentrations, probably due to increased HNO3 formation and conversion to aerosols under more abundant ozone and radical conditions after the $NO_x$ reduction. However, a nation-wide $NO_x$ reduction decreased SMA $PM_{2.5}$ concentrations even during winter, which implies that nation-wide reductions would be more effective to curtail SMA $PM_{2.5}$ concentrations than localized efforts.

A Study on the Environmental Carrying Capacity Assessment of Chongju City (도시 환경용량평가에 관한 연구 -청주시를 사례로-)

  • Lim, Jae-Ho;Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.1
    • /
    • pp.25-36
    • /
    • 2002
  • The purpose of this study is to assess the environmental carrying capacity of Chongju City for the environmental management and the urban growth management. The urban environmental carrying capacity assessment of the city by the index of ecological footprint(EF), shows that the ecosystem of the city has been overloaded and most of the deficiencies has come from outside of the city. The EF index, the area of land per capita required for production and consumption in the city, was 1.731 ha per capita in 1989 and 1.901 ha per capita in 1999. On the other side, the ecologically productive land is 0.0175 ha per capita. It means that every citizen owes 1.88 ha per capita to the ecosystem in 1999. The land consumption of the city has increased by 0.1705 ha per capita during the last 10 years. The capacity of infrastructure and the service supply estimated by the Onishi model does not exceed the demand of the city in 1999. But the rapidly increasing population and fast urban growth need the expansion of the capacity. The water supply capacity of the city appears to be sufficient in 1999, but the water supply demand will increase in the future. The capacity of sewage treatment facilities seems to be sufficient, but the higher level of sewage treatment facilities should be adopted for the improvement of water quality as the generation of sewage will increase and its characteristics will also make the wastewater treatment difficult. Due to the decrease of solid waste generated, the land fill capacity for solid waste disposal is not insufficient at present, but the capacity will be saturated in the near future. Therefore, the scientific management system of solid wastes should be introduced. The air quality of the city meets both the national air quality standard and WHO recommendation standard, but the strong regulation and control of automobile emission gas such as CO, $CO_2$, NOx and HC is required for clean air.

A Study on the Distribution Characteristics and Countermeasures of Concentrations of Ambient PM10 and PM2.5 in Yangju, South Korea

  • Dohun Lim;Yoonjin Lee
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.701-716
    • /
    • 2022
  • This study investigated the distribution behaviors of PM2.5 and PM10 at two air quality monitoring sites, Go-eup (GO) and Backseokeup (BS), located in Yangju City, South Korea. The amounts of emissions sources of pollutants were analyzed based on the Clean Air Policy Support System (CAPSS), and the contribution rates of neighboring cities were enumerated in Yangju. Yangju has a geological basin structure, and it is a city with mixed urban and rural characteristics. The emission concentration of particulate matter was affected by geological and seasonal factors for all sites observed in this study. Therefore, these factors should be considered when establishing policies related to particulate matter. Because the official GO and BS station sites in Yangju are both situated in the southern part of the city, the representativeness of both stations was checked using correlation analysis for the measurement of PM2.5 and PM10 by considering two more sites-those of Bongyang-dong (BY) and the Gumjun (GJ) industrial complex. The data included discharge amounts for business types 4 and 5, which were not sufficiently considered in the CAPSS estimates. Because the 4 and 5 types of businesses represent over 92.6% of businesses in this city, they are workplaces in Yangju that have a significant effect on the total air pollutant emission. These types of businesses should be re-inspected as the main discharge sources in industry, and basic data accumulation should be carried out. Moreover, to manage the emission of particulate matter, attainable countermeasures for the main sources of these emissions should be prepared in a prioritized fashion; such countermeasures include prohibition of backyard burning, supervision of charcoal kilns, and management of livestock excretions and fugitive dust in construction sites and on roads. The contribution rates by neighboring cities was enumerated between 6.3% and 10.9% for PM2.5. Cooperation policies are thought to be required with neighboring cites to reduce particulate matter.

A Prediction on Indoor Contaminant Diffusion Characteristics of a Training Ship by Mechanical Ventilation System (기계식 환기시스템에 의한 선내 오염물질 확산 특성 예측)

  • Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1124-1131
    • /
    • 2011
  • This study performed the prediction about the indoor contaminant's diffusion characteristics which can be affected by the mechanical ventilation system on a training ship. The results are as followings. It is clear that the contaminants are spread to most of the indoors, regardless of the contamination beginning zone. About 65~100 minutes later, the contaminant densities of whole indoor zones are evaluated as clean. Comparing the contamination beginning zone being located at higher deck(scenario A) to the contamination beginning zone being located at lower deck(scenario B), although the contaminant density by scenario A is 10 times higher than that by scenario B, the number of contaminated zones are 50% less. The contaminant densities are evaluated as to be rapidly decreased when the outside air induction ratio against design volume is over 75%.

Characterization of Volatile Organic Compounds(VOCs) Concentrations in Jinju (진주시 대기중 휘발성 유기화합물의 농도특성 기초조사)

  • Park, Jeong-Ho;Park, Hyung-Gun;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • In order to study the seasonal patterns and possible origins of air concentrations of volatile organic compounds(VOC), measurements were taken with GC-MS at 3 sampling sites in Jinju for 12 months from Mar. 2010 to Feb. 2011. Atmospheric VOC are sampled on tubes containing solid adsorbents(Tenax TA) with a time resolution of 2hrs. Composition and concentration of VOC are analysed with a GC system equipped with thermal desorption apparatus(ATD). The most abundant compound appeared to be Toluene, Ethylbenzene and m,p-Xylene. The mean concentrations of Benzene were 0.20 ppb at GN site, 0.18 ppb at DA site, and 0.25 ppb at SP site, respectively. VOC concentration showed a strong seasonal variation, with higher concentrations during the spring and lower concentrations during the summer. The results showed that monthly fluctuations in measured VOC concentrations depended on variations in the strength of sources, as well as on photochemical activity and meteorological conditions. In Jinju, the total VOC emissions for 2009 were estimated to be 4,407 ton/year by Clean Air Policy Support System(CAPSS). It is shown that solvent use 57.5%(2,534 ton/yr), waste treatment and disposal 23.3%(1,025 ton/yr), and mobil source-road traffic 12.2%(537 ton/yr) are the most significant anthropogenic source.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

Design for Landfill Gas Application by Low Calorific Gas Turbine and Green House Optimization Technology (Low Calorific Gasturbine 매립지 적용 및 유리온실 운용기술 설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin;Rhim, Sang-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.244.1-244.1
    • /
    • 2010
  • Bio energy development by using Low Calorific Gas Turbine(LCGT) has been developed for New & Renewable energy source for next generation power system, low fuel and operating cost method by using the renewable energy source in landfill gas (LFG), Food Waste, water waste and Livestock biogas. Low calorific fuel purification by pretreatment system and carbon dioxide fixation by green house system are very important design target for evaluate optimum applications for bio energy. Main problems and accidents of Low Calorific Gas Turbine system was derived from bio fuel condition such as hydro sulfide concentration, siloxane level, moisture concentration and so on. Even if the quality of the bio fuel is not better than natural gas, LCGT system has the various fuel range and environmental friendly power system. The mechanical characterisitics of LCGT system is a high total efficiency (>70%), wide range of output power (30kW - 30MW class) and very clean emmission from power system (low NOx). Also, we can use co-generation system. A green house designed for four different carbon dioxide concentration from ambient air to 2000 ppm by utilizing the exhaust gas and hot water from LCGT system. We look forward to contribute the policy for Renewable Portfolio Standards(RPS) by using LCGT power system.

  • PDF