• Title/Summary/Keyword: Air circulation

Search Result 542, Processing Time 0.03 seconds

Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season (고온기 근권냉방방식에 따른 냉방효과와 토마토 생육)

  • 이재한;권준국;권오근;최영하;박동금
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.81-87
    • /
    • 2002
  • This study was conducted to investigate the cooling efficiency and growth of tomatoes by root zone cooling device using a pad-box and cultivated system. The structure of the root zone cooling system using a pad-box was four piece of pads bonded an the side and a fan set at the bottom. Cool wind was generated by the outside air which was punched at intervals of 10 cm along three rows. Cold wind flowed to the root zone in the culture medium. The root zone cooling efficiency of cold wind generation by using a pad-box flowing through a wet-pad was determined. Major characteristic of this cuttural system consist of bed filled with a perlite medium and a ventilation pipe using PVC. The cold wind generation by a pad box (CWP) was compared to that of cold wind generation by a radiator (CWR), cold water circulation using a XL-pipe (CWX) and the control (non-cooling). When the temperature of water supplied was 16.2-18.4$^{\circ}C$, temperatures in the medium were 20.5~23.2$^{\circ}C$ for CWP 22.7~24.2$^{\circ}C$ for CWR, 22.8~24.27$^{\circ}C$ for CWX and 23.1~-29.6$^{\circ}C$ for the control. The results show that the cold wind temperature using the pad-box was lower by 1~2$^{\circ}C$ than that of cold water circulation in the XL-pipe and lower by 5~6$^{\circ}C$ than that of the control. Growth such as leaf length, leaf width, fresh weight and dry weight, was greater in three root zone cooling methods than in the control. Root activity was higher in the rat zone cooling methods than in the control. However, there was no significant difference among root zone cooling methods.

Prostatic Artery Embolization for Lower Urinary Tract Symptoms via Transradial Versus Transfemoral Artery Access: Single-Center Technical Outcomes

  • Ryun Gil;Dong Jae Shim;Doyoung Kim;Dong Hwan Lee;Jung Jun Kim;Jung Whee Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.5
    • /
    • pp.548-554
    • /
    • 2022
  • Objective: To evaluate the safety and feasibility of prostatic artery embolization (PAE) via transradial access (TRA) compared with transfemoral access (TFA). Materials and Methods: This retrospective study included 53 consecutive men with lower urinary tract symptoms (LUTS) who underwent PAE between September 2018 and September 2021. Thirty-one patients (mean age ± standard deviation: 70.6 ± 8.4 years) were treated with TFA, including 14 patients treated before adopting TRA. Since December 2019, TRA has also been attempted with the procedure's selection criteria of patent carpal circulation and a height ≤ 172 cm, with 22 patients treated via TRA (69.1 ± 9.6 years). Parameters of technical success (defined as successful bilateral embolization), clinical success (defined as LUTS improvement), procedural time, radiation dose, and adverse events were compared between the two groups using the Fisher's exact test, independent sample t test, Wilcoxon signed-rank test, or Mann-Whitney test. Results: All patients received at least one-side PAE. Technical success of PAE was achieved in most patients (TRA, 21/22; TFA, 30/31; p > 0.999). No technical problem-related conversion from TRA to TFA occurred. The clinical success rate was 85% (11/13) in patients with TRA, and 89% (16/18) in patients with TFA for follow-up > 2 weeks post-PAE (median, 3 months) (p > 0.999). The median procedure time was similar in both groups (TRA, 81 minutes vs. TFA, 94 minutes; p = 0.570). No significant dose differences were found between the TRA and TFA groups in the dose-area product (median Gycm2, 95 [range, 44-255] for TRA and 84 [34-255] for TFA; p = 0.678) or cumulative air kerma (median mGy, 609 [236-1584] for TRA and 634 [217-1594] for TFA; p = 0.551). No major adverse events occurred in either of the groups. Conclusion: PAE via TRA is a safe and feasible method comparable to conventional TFA. It can be safely implemented by selecting patients with patent carpal circulation and adequate height.

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul - (대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Lee, Myung-Hun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.491-499
    • /
    • 2020
  • Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Dispersion of Air Pollutants from Ship Based Sources in Incheon Port (인천항의 선박오염원에서 배출된 대기오염물질의 확산)

  • Kim, Kwang-Ho;Kwon, Byung Hyuk;Kim, Min-Seong;Lee, Don-Chool
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.488-496
    • /
    • 2017
  • Emissions of pollutants from ship-based sources are controlled by the International Maritime Organization (IMO). Since pollutants emitted from ship may be dispersed to the land, controlling emissions from ships is necessary for efficient air quality management in Incheon, where exposure to ship-based pollution is frequent. It has been noted that the ratios of air pollutant emissions from coastal areas to inland areas are about 14% for NOx and 10% for SOx. The air quality of coastal urban areas is influenced by the number of ships present and the dispersion pattern of the pollutants released depending on the local circulation system. In this study, the dispersion of pollutants from ship-based sources was analyzed using the numerical California Puff Model (CALPUFF) based on a meteorological field established using the Weather Research and Forecasting Model (WRF). Air pollutant dispersion modeling around coastal urban regions such as Incheon should consider point and line sources emitted from both anchored and running ships, respectively. The total average NOx emissions from 82-84 ships were 6.2 g/s and 6.8 g/s, entering and leaving, respectively. The total average SOx emissions from 82-84 ships, entering and leaving, were 3.6 g/s and 5.1 g/s, respectively. The total average emissions for NOx and SOx from anchored ships were 0.77 g/s and 1.93 g/s, respectively. Due to the influence of breezes from over land, the transport of pollutants from Incheon Port to inland areas was suppressed, and the concentration of NOx and SOx inland were temporarily reduced. NOx and SOx were diffused inland by the sea breeze, and the concentration of NOx and SOx gradually increased inland. The concentration of pollutants in the area adjacent to Incheon Port was more influenced by anchored ship in the port than sea breezes. We expect this study to be useful for setting emission standards and devising air quality policies in coastal urban regions.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.

Effects of Leukocyte Depleted Priming Solution on Cardiopulmonary Edema by Extracorporeal Circulation (백혈구제거 혈액성 충진액이 체외순환 후 심폐부종에 미치는 영향)

  • Kim, Si-Hoon;Kim, Young-Du;Jin, Ung;Jo, Keon-Hyun
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.704-710
    • /
    • 2001
  • Background: Extracorporeal circulation using pump-oxygenator is an inevitable process to keep vital sign during cardiac arrest for open heart surgery. However, the diversion of blood through nonendothelialized channels appears to stimulate inflammatory response, and leukocyte activation may lead to cardiopulmonary edema. Our study evaluated the effect of leukocyte-induced cardiopulmonary edema using three different pump-oxygenator priming solutions; non-hemic crystalloid solution ; leukocyte-depleted homologous blood; non leukocyte-depleted homologous blood in priming solutions. Material and Method: Each different priming solution was used on five dogs, and the effect of leukocyte-induced cardiopulmonary edema during cardiopulmonary bypass(CPB) was evaluated. For each dog after 2 hours of exracorporeal circulation and another 4 hours of post-pump period, the dog was sacrificed and its heart and lung tissues were obtained for measuring Wet/Dry ratio. Arterial $O_2$partial pressure(PaO$_2$) and $CO_2$partial pressure(Pa$CO_2$) were checked. For the evaluation of ventilatory function, $CO_2$partial pressure difference between arterial blood (Pa$CO_2$) and exhaled air(Et$CO_2$) was measured. Result: 1. No significant difference was seen in arterial PaO$_2$and Pa$CO_2$among groups. 2. Ventilatory function evaluated by Pa$CO_2$and Et$CO_2$showed no significant difference between non-hemic and blood-mixed priming solution (P<0.05). 3. Cardiac and lung Wet/Dry ratios were remarkedly lower in the leukocyte-depleted group. There was no significant difference between the non-hemic and blood-mixed groups. Conclusion: Based upon this result, we concluded that the leukocyte depletion from homologous blood of CPB priming solution has a beneficial effect in reducing cardiopulmonary edema compared with non leukocyte-depleted or crystalloid priming solutions.

  • PDF

The Study of Standardization of Temperature Distribution of Interstitial Hyperthermia -In Phantoms and Living cat's brain tissue (Normal Tissue)- (915 MHz 극초단파 자입온열시 온도분포 적정화에 관한 연구 -조직등가물 및 가묘대뇌를 대상으로-)

  • Kyoung Hwan Koh;Cho Chul Koo;Park Young Hwan;Yoo Seong Yul;Kim Jong Hyun;Lee Seung Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.7-15
    • /
    • 1990
  • The ultimate objective of our experiment is to obtain the precise distribution of temperature in malignant tumors occurring in cerebral parenchyme of human beings when we will carry out interstitial hyperthermia in the near future. To achieve this purpose, first of all, it is necessary to make an attempt at performing interstitial hyperthermia in vivo under the similar condition of human beings. Therefore, we chose cats as materials much alike tissue characteristics of human beings. Moreover, it is also necessary to get the basic data from dynamic phantom in order to standardize and compare results obtained from interstitial hyperthermia carried out in cats. By having performed these experiments we got the following results. 1) On doing interstitial hyperthermia with 915 MHz microwave, the possible treated volume was 2 cm by 2 cm by 6 cm according to $50\%$ specific absorption rate (SAR). 2) The distribution of temperature within non-circulated static phantom was much the same as power density in air, but we observed that the temperature, within $5\~10$ minutes, rose to more higher than $55^{\circ}C$ not measured with Ga-As fiberoptic thermistor which was not impeded by microwave after performing interstitial hyperthermia. 3) Within dynamic phantom in which normal saline was circulating, temperature reached steady state which was maintained for more than 45 minutes through transit period in 5 minutes after starting interstitial hyperthermia. 4) When we interrupted circulation in the dynamic phantom, we observed that temperature rose to the same level as in the static phantom. 5) We could carry out interstitial hyperthermia safely when we used the generating power below 5 watts. Abrupt interruption of circulation caused a rapid increase in temperature. Times taking to rise to maximum $55^{\circ}C$ were 15.2 minutes (SE 0.4),9.7 minutes (SE 0.3), and 6.3 min-utes (SE 0.4) respectively with generating powers of 5,10, and 15 watts.

  • PDF

Estimation of Aerosol Radiative Forcing by AGCM (대기 대순환 모형을 이용한 에어로졸의 복사 강제 추정)

  • Hong, Sung-Chul;Chung, Il-Ung;Kim, Hyung-Jin;Lee, Kyu-Tae;Lee, Jae-Bum
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.623-631
    • /
    • 2008
  • Many recent studies have concentrated upon the radiative effects of atmospheric aerosols. Though their scattering and absorption of radiation, aerosols can also induce some other important environment effects. In this study, new radiation code and aerosol data within Atmosphere General Circulation Model (AGCM) is used to assess the aerosol radiative forcing and to analyze relative climate effects. The new Kangnung National University AGCM Stratospheric-15 (KNU AGCM ST15) was integrated by using two sets of radiative effect of aerosols: CTRL as not a radiative effect of aerosols and AERO as a radiative effect of aerosols. Two cases show the difference of net shortwave radiation budget at top-of-atmosphere (TOA) is found to be about $-3.4Wm^{-2}$, at the surface (SFC) is about $-5.6Wm^{-2}$. Consequently the mean atmospheric absorption due to aerosol layer in global is about $2.2Wm^{-2}$. This result confirms the existence of a negative forcing due to the direct effect of aerosols at the surface and TOA in global annual mean. In addition, it is found that cooling over at the surface air temperature due to radiative effect of aerosols is about $0.17^{\circ}C$. It is estimated that radiative forcing of the net upward longwave radiation taken as the indirect effect of aerosol is much smaller than that of the direct effect as there is about $0.2Wm^{-2}$ of positive forcing both at TOA and at SFC. From this study, It made an accurate estimation of considering effect of aerosols that is negative effect. This may slow the rate of projected global warming during the $21^{st}$ century.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF