• Title/Summary/Keyword: Air chamber

Search Result 1,334, Processing Time 0.025 seconds

Effects of Ambient Conditions on the Atomization of Direct Injection Injector (분위기 조건이 직접분사식 인젝터의 미립화에 미치는 영향)

  • Lee, J.S.
    • Journal of ILASS-Korea
    • /
    • v.6 no.1
    • /
    • pp.25-34
    • /
    • 2001
  • Several efforts to meet the exhaust gas regulation have been undertaken by many researchers in recent years. Main researches are on development of design techniques of intake port and combustion chamber, atomisation of fuel and precise control of air-fuel ratio, post-treatment of exhaust gas and so on. Engine technology is changed from PFI to GDI to correspond with exhaust gas regulation. GDI technique makes it possible to preserve lean air-fuel ratio and control accurate air-fuel ratio. Nevertheless, It is not cleared that information of spray characteristics and atomization process are very dependent on fluctuation of pressure and change of temperature in intake stroke. In this study, a constant volume combustion chamber is manufactured to investigate various fluctuations of in-cylinder pressure for injection duration. It is taken photographs of injection process of conventional GDI injector using PMAS. Then, it was verified experimently that ambient conditions as temperature and pressure of combustion chamber have effects on process of spray growth and atomization of fuel.

  • PDF

Application & Examination of the Plan for Optimum Stability through Water-hammer in Pipe Line and Booster Pump Station (관로계통 및 가압펌프장 수격에 따른 최적 안정성 확보방안)

  • Ra, Beyong-Pil;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.19-24
    • /
    • 2009
  • This paper is performed to find out the stability of water-hammer in pipe line and pump station that is happened when additional water needs demanded. At first, the water supply construction project is planned to supply $6,000\;m^3/day$ through 17.9 km pipe line. But additional demand ($1,200\;m^3/day$) happened from Cheong-ra water reservoir. In this situation, air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) are needed to prevent water-hammer. When the additional water is supplied, the existing facilities (air-chamber, vacuum breaker valve) are sufficient to alleviate shock not changing capacity alteration, judging from the airspace change and rise. Therefore, there is no problem for water-hammer by installing air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) at the top of Yeo-ju hill.

A Research on the Characteristics of Spray-Induced Mixing and Thermal Decomposition of Urea Solution in SCR System (SCR 시스템의 요소용액 미립화 및 분해반응 특성 예측에 관한 전산 해석 연구)

  • 김주연;민병수;하지수;류승협
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.818-826
    • /
    • 2004
  • The spray-induced mixing characteristics and thermal decomposition of aqueous urea solution into ammonia have been studied to design optimum sizes and geometries of the mixing chamber in SCR(Selective Catalytic Reduction) system. The cold flow tests about the urea-injection nozzle were performed to clarify the parameters of spray mixing characteristics such as mean diameter and velocity of drops and spray width determined from the interactions between incoming air and injected drops. Discrete particle model in Fluent code was adopted to simulate spray-induced mixing process and the experimental results on the spray characteristics were used as input data of numerical calculations. The simulation results on the spray-induced mixing were verified by comparing the spray width extracted from the digital images with the simulated Particle tracks of injected drops. The single kinetic model was adopted to predict thermal decomposition of urea solution into ammonia and solved simultaneously along with the verified spray model. The hot air generator was designed to match the flow rate and temperature of the exhaust gas of the real engines The measured ammonia productions in the hot air generator were compared with the numerical predictions and the comparison results showed good agreements. Finally, we concluded that the design capabilities for sizing optimum mixing chamber were established.

Effect of Premixed Fuels Charge on Exhaust Emission Characteristics of HCCI Diesel Engine (HCCI 디젤엔진의 배기특성에 미치는 예혼합 연료의 영향)

  • Kim Myung Yoon;Yoon Young Hoon;Hwang Suk Jun;Kim Dae Sik;Lee Chang Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.182-189
    • /
    • 2005
  • In order to investigate the effect of premixed gasoline, diesel fuel, and n-heptane charges on the combustion and exhaust emission characteristics in a direct injection (DI) diesel engine, the experimental studies are performed. The premixed fuels are injected into the premixing chamber that installed upstream of the intake port in order to minimize the inhomogeneity effect of premixed charge. The injection nozzle for directly injected fuel is equipped in the center of the combustion chamber. The air temperature control system is equipped in the intake manifold to examine the effect of air temperature. The experimental results of this study show premixing fuel is effective method to reduce the NOx and soot emissions of diesel engine. NOx emissions are linearly decreased with increasing premixed ratio for the three kinds of premixed fuels. The heating of intake air $(80^{\circ}C)$ reduced the deterioration of BSFC in high premixed ratio, because it promotes evaporation of premixed diesel droplet in the premixing chamber.

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

An Experimental Study on the VOCs Concentration Variation using a Petroleum Spill Imitation Trial Test Chamber (원유유출 모의시험 챔버를 이용한 휘발성유기화합물(VOCs)의 농도변화에 관한 연구)

  • Chung, Jin-Do;Lee, Dong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.393-398
    • /
    • 2010
  • This study prepared and utilized an imitation trial test chamber for a petroleum spill to predict the concentration of discharged Volatile Organic Compounds in the air at the time of Tae-An peninsula's petroleum spill, which happened in December, 2007. The petroleum spill imitation trial test chamber measured and analyzed the concentration variation of total VOCs. As the ambient air velocity increased, so the concentration of VOCs decreased; and as the water temperature rose, the concentration of VOCs increased. Furthermore, it appears that total concentration of VOCs decrease by more than 90% 6 days after the initial petroleum spill compared to the initial concentration of VOCs.

Dynamic Response Analysis of Pressurized Air Chamber Breakwater Mounted Wave-Power Generation System Utilizing Oscillating Water Column (진동수주형 파력발전 시스템을 탑재한 압축공기 주입식 방파제의 동적거동 해석)

  • Lee, Kwang-Ho;Kim, Do-Sam;Yook, Sung-Min;Jung, Yeong-Hoon;Jung, Ik-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.4
    • /
    • pp.225-243
    • /
    • 2014
  • As the economic matters are involved, applying the WEC, which is used for controlling waves as well as utilizing the wave energy on existing breakwater, is preferred rather than installing exclusive WEC. This study examines the OWC mounted on a pressurized air chamber floating breakwater regarding the functionality of both breakwater and wave-power generation. In order to verify the performance as a WEC, the velocity of air flow from pressurized air chamber to WEC has to be evaluated properly. Therefore, numerical simulation was implemented based on BEM from linear velocity potential theory as well as Boyle's law with the state equation to analyze pressurized air flow. The validity of the obtained values can be determined by comparing the previous results from numerical analysis and empirically obtained values of different shapes. In the actual numerical analysis, properties of wave deformation around OWC system mounted on fixed type and floating type breakwaters, motions of the structure with air flow velocities are investigated. Since, the wind power generating system can be hybridized on the structure, it is expected to be applied on complex power generation system which generates both wind and wave power energy.

Sensitivity Study of the Flow-through Dynamic Flux Chamber Technique for the Soil NO Emissions

  • Kim Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E3
    • /
    • pp.75-85
    • /
    • 2005
  • A mathematical sensitivity analysis of the flow-through dynamic flux chamber technique, which has been utilized usually for various trace gas flux measurement from soil and water surface, was performed in an effort to provide physical and mathematical understandings of parameters essential for the NO flux calculation. The mass balance equation including chemical reactions was analytically solved for the soil NO flux under the steady state condition. The equilibrium concentration inside the chamber, $C_{eq}$, was found to be determined mainly by the balance between the soil flux and dilution of the gas concentration inside the chamber by introducing the ambient air. Surface deposition NO occurs inside the chamber when the $C_{eq}$ is greater than the ambient NO concentration ($C_{0}$) introducing to the chamber; NO emission from the soil occurs when the $C_{eq}$ is less than the ambient NO concentration. A sensitivity analysis of the significance of the chemical reactions of NO with the reactive species (i.e. $HO_{2},/CH_{3}O_{2},/O_{3}$) on the NO flux from soils was performed. The result of the analysis suggests that the NO flux calculated in the absence of chemical reactions and wall loss could be in error ranges from 40 to $85\%$ to the total flux.

The Evaluation of Multiplane-Parallel Chamber Using Crystal Plate as Ionization Medium for Therapeutic Radiation Beams

  • Young W. Vahc;Park, Kyung R.;Kim, Sookil;Chul W. Joh;Kim, Tae H.
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • There has been necessity of an air free ionization chamber using the gold-crystal-aluminium plates, henceforth called the crystal chamber. The crystal chamber formed of parallel plates is very small in size and has more response for absorbed dose of therapeutic radiation beams. The gold plate on the crystal facing the photon and electron beam acts as an intensifier of signals and crystal plate as an ionization medium respectively. Both the copper guard ring and the aluminum collecting electrode are connected to an electrometer. Using high energy photon (6, 15 MV) and electron (9, 12, 15, 18 MeV) beams, the responses of the crystal chamber are evaluated against a PTW Farmer-type chamber at a field size of 10${\times}$10cm$^2$ and 100 cm SSD. The responses of crystal chamber for therapeutic radiation electron and photon beams are greater in magnitude by several order than Farmer. The crystal chamber has good linearity without correction factor C$\_$t,p/ with respect to the signals, a reading reproduction with good accuracy and precision less than 0.5%, and has other useful functions in measuring radiation beams.

  • PDF

Evaluation of anti-viral efficiency of TiO2 coated air filter for airborn virus (공간 내 부유한 바이러스에 대한 광촉매 TiO2가 코팅된 에어 필터의 항바이러스 효율 평가)

  • Park, Geunyoung;Park, Sungjae;Koo, Hyun-Bon;Kim, Seongjun;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.173-182
    • /
    • 2019
  • Since airborne viruses have been known to aggravate indoor air quality, studies on the development of anti-viral air filter increase recently. In this study, the pressure drop and anti-viral efficiency of TiO2 coated ceramic ball filter were evaluated. After the filter being inserted into a commercial room air cleaner, chamber test with aerosolized bacteriophage MS2 was performed. The porosity of TiO2 coated ceramic ball filter was 0.85, and pressure drop was about 13 Pa for 1 m/s of air velocity. The anti-viral efficiency was about 93% when the reaction time was 25 minutes in a 1 ㎥ chamber.