• 제목/요약/키워드: Air Turbine

검색결과 650건 처리시간 0.032초

Air Layer Effect on the Performance Improvement of a Cross-Flow Hydro Turbine

  • Choi, Young-Do;Shin, Byeong-Rog;Lee, Young-Ho
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.37-43
    • /
    • 2010
  • The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. Field test is performed in order to measure the output power of the turbine by a new air supply method. CFD analysis on the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss at the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

터빈 로터 반사각에 따른 의료용 에어터빈 핸드피스의 성능에 관한 수치 해석 (Numerical Analysis on Performance of Dental Air Turbine Handpiece for Various Reflection Angles of Turbine Rotor)

  • 이정호;이상도;김귀순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.29-32
    • /
    • 2008
  • Dental high-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, yet little study has been reported on their flow and performance analysis. Therefore it is necessary to investigate turbine for the performance improvements of an air turbine handpiece. This paper presents pressure on turbine rotor and flow analysis in air turbine handpiece using CFD (computational fluid dynamics). Characteristics on each flow and pressure for four various reflection angles of turbine rotor are presented, and then performance change is analyzed about air turbine handpieces by CFD results.

  • PDF

스팀터빈의 공력성능 평가를 위한 공기 상사실험 (Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine)

  • 임병준;이은석;이익형;김영상;권기범
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.73-79
    • /
    • 2003
  • The steam turbine efficiency is an important factor in power plant. Accurate evaluation of steam turbine performance is essential. However, it is not easy to evaluate the steam turbine performance due to its high temperature and high pressure circumstance. Therefore most steam turbine performance tests were conducted by air similarity test. This paper described a test program for air similarity test of steam turbine at Korea Aerospace Research Institute. A test facility has been designed and built to evaluate aerodynamic performance of turbines. The test facility consists of air supply system, single stage test section, power absorption system, instrumentation and auxiliary system. For evaluation of steam turbine performance, the test of single stage axial turbine air similarity performance was conducted and uncertainty analysis was performed.

  • PDF

가스터빈 엔진용 공기터빈 시동기 성능에 관한 실험적 연구 (Experimental Research on the Performance of Air Turbine Starter for Gas Turbine Engines)

  • 김춘택;양인영;차봉준
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.27-32
    • /
    • 2012
  • Gas turbines for an aircraft have the start and restart capabilities within their flight envelop. It is an important item for engine qualification and substantiated with the test. Experimental investigations were carried out to find the relation between the corrected torque and the corrected rotating speed of an air turbine starter in this study. A dedicated air supply system for the air turbine starter and a special device to measure the torque and the rotating speed of the air turbine starter were developed and installed at the altitude engine test facility in Korea Aerospace Research Institute. Experimental results show that the relations between the corrected torque and the corrected rotating speed of the air turbine starter are linear and the inlet temperature and pressure conditions for the air turbine starter were found out to provide minimum required torque for the engine qualification test at various altitude. The start and restart tests for the currently developing engine were successfully performed using this experimental results.

가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석 (Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System)

  • 박현우;이정수;조건환;조진수
    • 한국항공우주학회지
    • /
    • 제47권12호
    • /
    • pp.881-889
    • /
    • 2019
  • 가스터빈 이차 유로의 프리스월 시스템은 터빈의 효율을 높이고 소재의 수명을 연장하기 위해 설치되는 냉각 장치이다. 본 연구에서는 프리스월 시스템의 설계점을 기준으로 가스터빈 외기 온도와 터빈 부하 변화에 따른 탈설계점 분석을 수행하였다. 탈설계점에서 내부 유동의 특성을 분석하기 위하여 유량계수와 단열계수를 비교하였다. 터빈 부하 증가에 따라 시스템 내부 냉각 공기의 체적 유량이 증가하였고, 단열계수 또한 20% 터빈 부하와 비교하여 100% 터빈 부하에서 30.46% 상승하였다. 외기 온도가 증가할수록 질량 유량과 냉각 공기의 밀도는 감소하였지만 체적 유량은 상승하였으며, 결과적으로 프리스월 시스템 내부의 냉각 성능은 향상되었다. 프리스월 시스템 출구에서 -20℃ 외기 온도와 비교하여 55℃ 외기 온도의 단열계수는 14.82% 향상되었다.

소수력발전용 횡류수차의 공기층효과에 의한 성능향상 (Performance Improvement of Cross-Flow type Small Hydro Turbine by Air Layer Effect)

  • 최영도;안영준;신병록;이동엽;이영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1070_1071
    • /
    • 2009
  • Recently, small hydropower attracts attention because of its clean, renewable and abundant energy resources to develop. Therefore, a cross-flow hydraulic turbine is proposed for small hydropower development in this study. The turbine‘s simple structure and high possibility of applying to the sites of relatively low effective head and large flow rate can be advantages for the introduction of the small hydropower development. The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. CFD analysis for the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss in the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

  • PDF

파력발전용 새로운 공기터빈 개발에 관한 연구 (Study of a New Air Turbine for Wave Energy Conversion)

  • 김태호;뢰호구준명;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.955-960
    • /
    • 2001
  • In order to develop an efficient turbine for wave energy conversion suitable for actual ocean conditions, a new type of the air turbine with staggered blades has been investigated experimentally. Experiments have been carried out under steady flow conditions. Both the running and starting characteristics under sinusoidally oscillating flow conditions are simulated by a CFD method using a quasi-steady analysis. It is known that the air turbine with staggered blades gives a better performance compared with conventional Wells turbine, and a proper design factor of the air turbine is discussed for the setting angle of the rotor.

  • PDF

Effect of Air Layer on the Performance of an Open Ducted Cross Flow Turbine

  • Wei, Qingsheng;Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.11-19
    • /
    • 2015
  • Recently, the cross flow turbines attract more attention for their good performance over a large operating regime at off design point. This study employs a very low head cross flow turbine, which has open inlet duct and has barely been studied before, to investigate the performance of the cross flow turbine with air suction from the rear part of the runner. Unlike conventional cross flow turbines, a draft tube is attached to the outlet of runner to improve the turbine performance. Water level and pressure in the draft tube are monitored to investigate the influence of air suction. Torque at local blade passage of three parts of runner is examined in detail under the conditions of different air suction. Consequently, it is found that with proper air suction in the runner chamber, the water level in the draft tube gradually drops to Stage 2 of the runner and the efficiency of the turbine can be raised by 10%. Overall, the effect of air-layer on the performance of the turbine is considerable.

지대치 형성이 치수온도에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT ON PULP TEMPERATURE DURING ABUTMENT PREPARATION)

  • 김병기
    • 대한치과보철학회지
    • /
    • 제14권1호
    • /
    • pp.47-54
    • /
    • 1976
  • Pulpal temperature is changed in response for various conditions which were mechanical, thermal, chemical and biological stimuli. This study was performed to determine the pulpal temperature changes which were using air turbine with air-water coolant, water coolant, and conventional dental engine with water coolant and no coolant on 28 canine of dogs. In order to record pulpal temperature, pulp chamber was opened on the labiocervical area of canine. Thermocouple was inserted into pulp chamber and was fixed with filling material(dycal). Changes of pulpal temperature were recorded on the physiograph, which had been standardized temperature degree, through thermocouple to thermistor bridge and carrier preamplifier. The amount of experimental temperature change to that of control was interpreted in the pulpal cavity. The obtained results were as followings: 1. The mean normal temperature was 33.07 centigrade. 2. The temperature was decreased than normal pulpal temperature. It was 12.04 centigrade in reduction by air turbine with air-water coolant, 7.17 centigrade in reduction by air turbine with air coolant, 5.54 centigrade in reduction by conventional engine with water coolant, and 1.26 centigrade in reduction by conventional engine with no coolant. 3. The time for maximal temperature change was 53.3 seconds in reduction by air turbine with air-water coolant, 73.4 seconds in reduction by air turbine with air coolant, 50.9 seconds in reduction by conventional engine with water coolant, and 27.1 seconds in reduction by conventional engine with no coolant. 4.. After reduction was ceased, the recovery time to normal pulp temperature was 287.1 seconds in air turbine with air-water coolant, 189.0 seconds in air turbine with air coolant, 86.9 seconds in conventional engine with water coolant, and 52.9 seconds in conventional engine with no coolant respectively.

  • PDF

스팀터빈의 공력성능 평가를 위한 공기 상사실험 (Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine)

  • 임병준;이은석;양수석;이익형;김영상;권기범
    • 한국유체기계학회 논문집
    • /
    • 제7권5호
    • /
    • pp.29-35
    • /
    • 2004
  • The turbine efficiency is an important factor in power plant, and accurate evaluation of steam turbine performance is the key issue in turbo machinery industry. The difficulty of evaluating the steam turbine performance due to its high steam temperature and pressure environment makes the most steam turbine tests to be replaced by air similarity test. This paper presents how to decide the similarity conditions of the steam turbine test and describes its limitations and assumptions. The test facility was developed and arranged to conduct an air similarity turbine performance test with various inlet pressure, temperature and mass flow rate. The eddy-current type dynamometer measures the turbine-generated shaft power and controls the rotating speed. Pressure ratio of turbine can be controled by back pressure control valve. To verify its test results, uncertainty analysis was performed and relative uncertainty of turbine efficiency was obtained.