• 제목/요약/키워드: Air Temperature

검색결과 10,359건 처리시간 0.037초

제트 유동장에서의 마일드 연소 및 오염물질 배출특성에 관한 전산해석 연구 (Computational Study of the MILD Combustion and Pollutant Emission Characteristics in Jet Flow Field)

  • 김유정;송금미;오창보
    • 한국연소학회지
    • /
    • 제17권4호
    • /
    • pp.60-65
    • /
    • 2012
  • The MILD combustion and pollutant emission characteristics were investigated computationally. The temperature of supplying air-stream and mixing rate (${\Omega}$) of exhaust gas in the air-stream were adjusted to investigate the effects of those parameters on the MILD combustion in jet flow field. The emission indices for NO (EINO) and CO (EICO) were introduced to quantify the amount of those species emitted from the combustion. The high-temperature region disappeared gradually as the mixing rate increased for fixed air-stream temperature. The EINO increased as the air-stream temperature became higher for fixed mixing rate, and the EINO decreased dramatically with increasing the mixing rate for each air-stream temperature condition. The EICO also decreased with increasing the mixing rate and it was nearly independent of air-stream temperature except for near ${\Omega}$ = 0.7. It was found that the CO supplied in the air-stream can be destroyed in the MILD combustion over the certain mixing rate.

도시 캐노피 층 기온과 상대습도의 일변화에 관한 수치 모의 (Numerical Simulations of Diurnal Variations of Air Temperature and Relative Humidity in the Urban Canopy Layer)

  • 박경주;한범순;진한결
    • 대기
    • /
    • 제31권3호
    • /
    • pp.295-309
    • /
    • 2021
  • Diurnal variations of air temperature and relative humidity in the Urban Canopy Layer (UCL) of the Seoul metropolitan area are examined using the Weather Research and Forecasting model coupled with the Seoul National University Urban Canopy Model. The canopy layer air temperature is higher than 2-m air temperature and exhibits a more rapid rise and an earlier peak in the daytime. These result from the multiple reflections of shortwave radiation and longwave radiation trapping due to the urban geometry. Because of the absence of vegetation in the UCL and the higher canopy layer air temperature, the canopy layer relative humidity is lower than 2-m relative humidity. Additional simulations with building height changes are conducted to examine the sensitivities of the canopy layer meteorological variables to the urban canyon aspect ratio. As the aspect ratio increases, net sensible heat flux entering the UCL increases (decreases) in the daytime (nighttime). However, the increase in the volume of the UCL reduces the magnitude of change rate of the canopy layer air temperature. As a result, the canopy layer air temperature generally decreases in the daytime and increases in the nighttime as the aspect ratio increases. The changes in the canopy layer relative humidity due to the aspect ratio change are largely determined by the canopy layer air temperature. As the aspect ratio increases, the canopy layer relative humidity is generally increased in the daytime and decreased in the nighttime, contrary to the canopy layer air temperature.

부산시 해운대구의 하기 도시 고온화 현상과 토지피복 구성과의 상관관계 (Correlation between the Trend toward Higher Temperature and Land Cover Structure in Haeundae District of Busan in Summer)

  • 윤성환;김성하
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.19-27
    • /
    • 2008
  • This study aims at examining the correlation between air temperature and urban structure such as land cover. For this, it measured summer air temperature by using data log type thermometer installed the inside of instrument screen, in the 9 points of elementary school in Haeundae, Busan. The accomplished results of this study are followings. 1) As altitude goes up 100m, air temperature drops to $0.6{\sim}1.0^{\circ}C$. 2) As building coverage ratio increases 10%, air temperature increases $0.3{\sim}0.4^{\circ}C$. 3) As floor space index increases 100%, air temperature increases $0.4{\sim}0.5^{\circ}C$. 4) As artificial coverage ratio increases 10%, air temperature increases $0.1{\sim}0.2^{\circ}C$. 5) As natural coverage ratio increases 10%, air temperature decreases $0.1{\sim}0.2^{\circ}C$.

증발기의 압력강하에 대한 상대습도의 영향 (Effects of Relative Humidity on the Evaporator Pressure Drop)

  • 김창덕;강신형;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

착상조건하에서 핀-관 열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Fin-Tube Heat Exchanger under Frosting Condition)

  • 이관수;박희용;이태희;이남교;이수엽;이명렬
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.319-328
    • /
    • 1995
  • In this study, the experiment with 2rows-2columns fin-tube heat exchanger under forced convection and frosting condition is performed. The influence of each operating condition(the temperature of air, the humidity of air, the velocity of air, the temperature of coolant) on the growth of frost layer, air-side pressure drop, and characteristics of heat transfer is investigated. The experimental results show that the frost thickness increases rapidly in the early stage of frost formation and increases linearly after sometime. The frost thickness increases with the increase of the inlet air humidity and velocity and the decrease of inlet air temperature and coolant temperature. It is also found that the total energy transfer rate increases with the increase of inlet air temperature and velocity and with the decrease of inlet air humidity and coolant temperature.

  • PDF

유입공기의 온도변화가 전자모듈의 냉각에 미치는 영향 (Cooling effect of an electronic module with a variation of the inlet air temperature)

  • 이진호;조성훈
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.264-273
    • /
    • 2001
  • The conjugate heat transfer from a protruding module in a horizontal channel with a variation of air temperature is experimentally investigated. It is an aim of this study is to estimate temperature difference between a module and air. This study is performed with a variation of parameters that are air temperatures($T_i,=25^{\circ}C{\sim}55^{\circ}C),$ thermal resistance($R_c=158 K/W),$ air velocities ( 4V_i=0.1$ m/s~l.5 m/s ), and input power (Q=3 W, 7 W ). The results show that as the thermal resistance increases, the effect of air temperatures are decreased. And input power was most effective parameter on the temperature difference between a module and air.

  • PDF

적외선 화상처리 장치를 이용한 건조초기 목재 표면 온도 측정 (Measuring Temperature on Wood Surface at the Beginning of Drying Using IR Image Measuring System)

  • 이관영;강호양;이민경
    • 한국가구학회지
    • /
    • 제17권3호
    • /
    • pp.79-85
    • /
    • 2006
  • Temperature of board surface was monitored during drying using an IR image measurement system. Boards were water-saturated and dried at the levels of four temperatures and three air velocities. At higher DB the surface temperature increased more steeply and level off period was significantly short. At the DB temperatures of 70, 80, $90^{\circ}C$ the period where the surface temperature was equivalent to WB temperature was constant regardless of air velocity while at $60^{\circ}C$ it decreased as air velocity increased. It was confirmed that a surface transfer coefficient increased with DB temperature. Variation of temperature profile on a wood surface increased with DB temperature and air velocity.

  • PDF

천장복사냉방의 온열쾌적성 평가에 관한 연구 (Evaluation of Thermal Comfort in Ceiling Cooling System)

  • 이주연
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.287-293
    • /
    • 2008
  • The purpose of this study was to clarify the effects of air and ceiling temperatures on a type of ceiling cooling system that involves cool water circulation. The experiment is conducted in summer. The subjects (11 young females) are exposed to the following conditions: combinations of air temperatures $(27^{\circ}C,\;29^{\circ}C,\;31^{\circ}C)$ and ceiling temperature of $(22.7^{\circ}C,\;23.7^{\circ}C,\;24.7^{\circ}C)$ in still air and RH 50%. The following results were obtained; the thermal sensation vote is neutral at a mean skin temperature of $34.5^{\circ}C$. The ceiling temperature affected different parts of the body. For example, the forehead, scapula and abdomen produced different skin temperatures. Thermal comfort vote was rated as comfortable at high temperature environment. The satisfaction from the ceiling temperature was valued comfortable zone in this experiment. Mean skin temperature showing higher thermal neutrality temperature than existing studies for floor and wall radiation cooling results.

하계에 도심지에서 관측된 흑구온도의 특성 분석 (On the Characteristics of Globe Temperature Variation Observed at Downtown in Summer Season)

  • 박종길;정우식;김석철;박길운
    • 한국환경과학회지
    • /
    • 제17권8호
    • /
    • pp.907-918
    • /
    • 2008
  • In order to monitor the impact of high temperature which is seen frequently with climate change, we investigated the monthly change in globe temperature, air temperature, mean radiant temperature and effective radiant heat flow, because the four well reflect thermal radiation from bio-meteorological aspect. Both globe temperature and air temperature showed an increasing trend every month. Compared to air temperature, globe temperature had a wider range of temperature change and was more influenced by meteorological element such as precipitation. Diurnal trends of air temperature, globe temperature and the difference between their temperature had the lowest value before the sunrise and the highest around $1300{\sim}1500$ LST, showing the typical diurnal trends. Globe temperature and the difference between their temperature had a sharp increase around $1000{\sim}1100$ LST, maintained high value until 1700 LST and then reclined, though varied by month. The difference between globe temperature and air temperature was highly dependent on the amount of precipitation and clouds. The duration in which globe temperature was higher than air temperature was the lowest in July. Therefore the amount of precipitation was the most affecting, followed by the amount of clouds and wind. In order to find out the diurnal trends of temperature in city center and city outskirts, we assumed the roof of a concrete build ing as a city center, and the grass-covered observatory of the Gimhae International Airport as city outskirts. The diurnal trends of temperature in the two sites showed a strong correlation. The highest and lowest temperature also had the same trend.

자동차 에어컨 쾌적제어 알고리즘 개발을 위한 운전자 온열감성 평가 : 제 1 보-운전자의 에어컨 조작 선호도 (Comfort Control Algorithm Development of Car Air Conditioner using Thermal Comfort Evaluation of Driver : Part I - Air-conditioning Operating Preference of Driver)

  • 김민수;김동규;이기덕;금종수
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.294-300
    • /
    • 2014
  • In this study, we investigated and evaluated the air conditioning operation of the driver according to the temperature difference between the inside and outside of a car parked outside during the summer. We suggest including a comfort mode to the car air conditioning system to improve the thermal comfort of the driver, in which the comfort can be maintained for a longer time. For the a result of our experiment, in the cases with temperature of above $45^{\circ}C$ inside of the car, the subjects preferred strong air blow with the face and the arms in the direction of the blow. In the cases with temperature of below $40^{\circ}C$ inside of the car, the subjects preferred lower volume of air blow. In the temperature below $28.1^{\circ}C$ inside of the car, the mean temperature on the skin of the driver reached the comfort zone.