• Title/Summary/Keyword: Air Space Above

Search Result 135, Processing Time 0.024 seconds

A simple formula for insertion loss prediction of large acoustical enclosures using statistical energy analysis method

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.894-903
    • /
    • 2014
  • Insertion loss prediction of large acoustical enclosures using Statistical Energy Analysis (SEA) method is presented. The SEA model consists of three elements: sound field inside the enclosure, vibration energy of the enclosure panel, and sound field outside the enclosure. It is assumed that the space surrounding the enclosure is sufficiently large so that there is no energy flow from the outside to the wall panel or to air cavity inside the enclosure. The comparison of the predicted insertion loss to the measured data for typical large acoustical enclosures shows good agreements. It is found that if the critical frequency of the wall panel falls above the frequency region of interest, insertion loss is dominated by the sound transmission loss of the wall panel and averaged sound absorption coefficient inside the enclosure. However, if the critical frequency of the wall panel falls into the frequency region of interest, acoustic power from the sound radiation by the wall panel must be added to the acoustic power from transmission through the panel.

Experimental investigation on the room temperature active magnetic regenerator with permanent magnet array (영구자석 배열을 이용한 능동형 자기재생 냉동기에 대한 실험적 연구)

  • Kim, Young-Kwon;Jeong, Sang-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.186-191
    • /
    • 2008
  • In this study, a room temperature AMRR (Active magnetic regenerative refrigerator) was fabricated, and experimentally investigated. Gadolinium (Gd) was selected as a magnetic refrigerant with Curie temperature of 293 K. Permanent magnet was utilized to magnetize and demagnetize the AMR. To produce large magnetic field above 1 T in the magnetic refrigeration space, a special arrangement of permanent magnets, so called Halbach array, is employed. Sixteen segments of the permanent magnets magnetized different direction, constitute a hollow cylindrical shaped permanent magnet. The AMR is reciprocated along the bore of the magnet array and produces cooling power. Helium is selected as the working fluid and a helium compressor is utilized to supply helium flow to the regenerator. The fabricated AMRR has different structure and compared to a convectional AMRR since it has an additional volume after the regenerator. Therefore, the cooling ability is generated not only by magnetocaloric effect of magnetic refrigerant but also by the pulse tube effect. It is verified that the cooling ability of AMR is increased due to the magnetocalric effect by the fact that the temperature span becomes $16^{\circ}C$ while the temperature span is only $8^{\circ}C$ when the magnetic field is not applied to the regenerator.

  • PDF

The Study of the Design Tests for Current Capability according to ANSI (ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF

A Study on the Design Guidelines of a Storage for Conservation of Relics in a Museum (문화재 보존을 위한 박물관 수장고의 공간계획 지침 연구)

  • Jung Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.144-154
    • /
    • 2006
  • Except the time when relics of a museum are exhibited or loaned to the public, they are stored in a storage. In addition, it is common view that collections are exhibited a few of total stored collections in a museum. Therefore, the environmental condition of a storage is an important factor. Hereby, the purpose of this study is to suggest the design guidelines of a storage for conservation of relics in a museum. The results from this study are as follows briefly. First, location of storages has to be located and centralized above ground against preservation environment and additional renovation. Second, for storage size, It is reasonable to secure long-term experimental data after planning about 20% of whole section in present domestic situation. Third, in order to prevent environmental deterioration due to short storage floor space, adequate storage height has to be secured against a mezzanine deck and spare storages need to be planned. Where a mezzanine deck is designed, detailed plans have to be supported for equal micro climate in a storage. Fourth, in respect of environmental control of storages, finish materials with adjustment ability on relative humidity have to be used after the system is installed jointly direct and indirect way by air chamber, considering domestic condition for management of intermittent ventilation.

Structural and Magnetic Properties of the Brownmillerite $Ca_2Al_xFe_{2-x}O_5$ System

  • 김귀야;로권선;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.10
    • /
    • pp.934-938
    • /
    • 1995
  • A series of solid solutions in the Ca2AlxFe2-xO5 (x=0.00, 0.50, 0.66, 1.00 and 1.34) system with brownmillerite structure has been synthesized at 1100 ℃ under an atmospheric air pressure. The solid solutions are analysed by powder x-ray diffraction analysis, Mohr salt titration, thermal analysis, and Mossbauer spectroscopic analysis. The x-ray diffraction analysis assigns the compositions of x=0.00 and 0.50 to the space group Pcmn and those of x=0.66, 1.00, and 1.34 to the Ibm2. Mo&ssbauer spectra have shown the coordination state and disordering of Al3+ and Fe3+ ions. The substituting preference of Al3+ ions for the tetrahedral site decreases with increasing x value. Magnetic susceptibility of the system has been measured in the temperature range of 5 K to 900 K. The solid solutions of the compositions of x=0.00, 0.50 and 0.66 have shown a thermal hysteresis and the thermoremanent magnetization gap decreases with increasing x value in the above systems. However the compositions of x=1.00 and 1.34 do not show the hysteresis. The exchange integral is calculated from Fe3+ ion occupancy ratio. The integral decreases with x value and thus the magnetic transition temperature decreases with the increasing x value.

A Study on the Timing and Method of the Final Price of Air Ticket in Computerised Booking System (인터넷 항공권 예약시스템에서의 '최종가격' 표시시기와 방법 - 2015년 1월 15일 EU사법재판소 C-573/13 판결을 중심으로 -)

  • Sur, Ji-Min
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.32 no.1
    • /
    • pp.327-353
    • /
    • 2017
  • The issue submitted to the Court of Justice on the merits of case C---573/13 originated from a claim brought in the context of a dispute between Air Berlin and the German Federal Union of Consumer Organisations and Associations. The challenge concerned the way in which air fares were displayed in Air Berlin's computerised booking system. The system was organised in such a way that, after selecting a date and a departure airport, one would find all possible flight connections in a summary table. However, the final price of the ticket was displayed only for the clicked connection, and not for all connections, thus preventing customers from being able to compare such price with the prices of other connections. The German Federal Union took the view that this practice did not meet the requirements laid down by Article 23 of Regulation (EC) No. 1008/2008, which requires transparency in the prices set for air services. This led the German State to bring an injunctive action to cause Air Berlin to discontinue said practice. The claim was upheld at both the application and appeal stage of the relevant proceedings. Subsequently, Air Berlin submitted the matter to the German Federal High Court, which decided to stay the proceedings and ask for a preliminary ruling from the Court of Justice as to 1. whether Article 23 of Regulation (EC) No. 1008/2008 must be interpreted as meaning that, during the computerised booking process, the final price to be paid must be indicated at all times when prices of air services are shown, including when they are shown for the first time; and 2. whether, during the computerised booking process, the final price must be indicated only for the air service specifically selected by the customer or for each air service shown. In a nutshell, the Court, by the here---discussed judgment determined that Article 23 of Regulation (EC) No. 1008/2008 must be interpreted as meaning that, in the context of a computerised air ticket booking system, the final price to be paid must be indicated not only for the air service specifically selected by the customer, but also for each air service in respect of which the fare is shown. Clearly the above judgment will place air companies under an obligation to update and adjust (when needed) their computerised ticket booking and payment systems, in consideration of the primary need for consumers to be aware at all times of the actual price payable for a ticket and be able to compare the price of the service selected with the prices for other air services in respect of which the fare is shown.

  • PDF

New Environmental Impact Assessment Technology (신환경영향평가기술(新環境影響評價技術)의 개발방향(開發方向))

  • Han, Sang-Wook;Lee, Jong-Ho;Nam, Young-Sook
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.4
    • /
    • pp.277-290
    • /
    • 2000
  • The purpose of this study is to identify the problems of environmental impact assessment(EIA) and to suggest new EIA technology. The problems of EIA in Korea can be summarized as follows. First, the EIA does not reflect the impact of policy, plan and program on environment. Second, the project EIA does not consider the cumulative impacts such as additive impacts, synergistic impacts, threshold/saturation impacts, induced and indirect impacts, time-crowded impacts, and space-crowded impacts. Third, the EIA techniques in Korea are not standardized. Finally, the present EIA suggests only alternatives to reduce adverse impacts. To solve above-mentioned problems, the development of new EIA technology is essential. First, the new EIA technology should be developed toward pollution prevention technology and comprehensive and integrated environmental management technology. Second, new fields of EIA for pollution prevention contain strategic environmental assessment, cumulative impacts assessment, socio-economic impact assessment, cyber EIA and EIA technology necessary after the reunification of Korean Peninsula. Third, EIA technology for integrated environmental management contains the development of integated environment assessment system and the development of packaged EIA technology. The EIA technology for integrated environmental assessment system contains (1) development of integrated impact assessment technology combining air/water quality model, GIS and remote sensing, (2) integrated impact assessment of EIA, traffic impact assessment, population impact assessment and disaster impact assessment. (3) development of integrated technology combining risk assessment and EIA (4) development of integrated technology of life cycle assessment and EIA, (5) development of integrated technology of spatial planning and EIA, (6) EIA technology for biodiversity towards sustainable development, (7) mathematical model and GIS based location decision techniques, and (8) environmental monitoring and audit. Furthermore, there are some fields which need packaged EIA technology. In case of dam development, urban or industrial complex development, tourist development, landfill or combustion facilities construction, electric power plant development, development of port, road/rail/air port, is necessary the standardized and packaged EIA technology which considers the common characteristics of the same kind of development project.

  • PDF

Improvement of hot work environment in the curing processes of a tire manufacturing company (타이어 제조공장 가류공정의 온열환경 개선에 관한 연구)

  • Lim, Jung-ho;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Generally, the tire curing process is the process in which the sulfur is added and subsequently the tire is heated to give the tire elasticity. In this process, all kinds of the chemicals in the tire are emitted with a lot of heat. The chemical fume and heat aggravate the work environment. To solve this problem, 92 local exhaust ventilators and 8 gravity ventilators were used, but not satisfactory yet. Preliminary survey showed that the temperatures in the process were very high: 30.3, 32.9 and $37.2^{\circ}C$ at 2, 4 and 6m above the ground level, respectively in the winter (outside temperature was $2^{\circ}C$). It can be imagined that the process is severely hot in the summer time. The higher temperature distribution in the higher space tells us that the hot plume could not be removed with the existing ventilation systems. Therefore, in this study, some alternative ventilation systems were designed. The partitions were used to contain the hot plume to increase the capture efficiency. The gravity ventilators were newly designed to improve the extraction efficiency of hot fume. To satisfy the balance of pressure in the curing process, some supply air system was introduced by renewing the existing air conditioning system. Many alternative solutions were evaluated by using computational fluid dynamics modelling. The best and applicable solution was selected and the existing ventilation system was modified. After implementing the new ventilation system, the hot environment was much improved. The temperature reduction in the curing process was about $6.4^{\circ}C$.

A Reconfigurable Integration Test and Simulation Bed for Engagement Control Using Virtualization (가상화 기반의 재구성 용이한 교전통제 통합시험시뮬레이션 베드)

  • Kilseok Cho;Ohkyun Jeong;Moonhyung Yoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.91-101
    • /
    • 2023
  • Modeling and Simulation(M&S) technology has been widely used to solve constraints such as time, space, safety, and cost when we implement the same development and test environments as real warfare environments to develop, test, and evaluate weapon systems for the last several decades. The integration and test environments employed for development and test & evaluation are required to provide Live Virtual Construction(LVC) simulation environments for carrying out requirement analysis, design, integration, test and verification. Additionally, they are needed to provide computing environments which are possible to reconfigure computing resources and software components easily according to test configuration changes, and to run legacy software components independently on specific hardware and software environments. In this paper, an Integration Test and Simulation for Engagement Control(ITSEC) bed using a bare-metal virtualization mechanism is proposed to meet the above test and simulation requirements, and it is applied and implemented for an air missile defense system. The engagement simulation experiment results conducted on air and missile defense environments demonstrate that the proposed bed is a sufficiently cost-effective and feasible solution to reconfigure and expand application software and computing resources in accordance with various integration and test environments.

A Study on Fire ventilation design of road tunnel (도로터널에서의 화재환기 설계에 관한 연구)

  • Kim, Myung-Bae;Choi, Byung-Il;Choi, Jun-Seok;Han, Yong-Shik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • The several assumptions and design parameters to determine the ventilation rate in tunnel ventilation system were examined. In longitudinal ventilating tunnel, the ventilation rate has been determined by the critical velocity above which the smoke propagation to the upstream of ventilating air is prevented. Based upon the examination of assumptions and experimental results, we suggested the improved method to determine the critical velocity. In transverse ventilating tunnel, we found that the ventilation rate has been determined in accordance with the custom rather than fire-smoke dynamics such as the critical velocity in the longitudinal ventilating tunnel. It is because the ventilation rate in the transverse ventilation system has been determined by considering only the ventilation of contaminant by vehicle. To improve the ventilation design parameters based upon the fire-smoke dynamics, we conducted model tunnel fire experiments. From the experimental results, smoke propagating distance and smoke filling were suggested as the design parameter to determine the ventilation rate in transverse ventilating tunnel. And tunnels in Europe designed by the custom is found to have the dangerous nature in view of fire safety.

  • PDF