• 제목/요약/키워드: Air Source Heat Pump

검색결과 282건 처리시간 0.026초

배열 이용형 흡수식 사이클 특성평가 (Characteristics Evaluation of Absorption Cycles using the Waste Heat)

  • 윤정인;권오경;문춘근
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.23-32
    • /
    • 1998
  • Fuel cells supply electric power and heat at work, and their exhaust gas is comparatively clear. So they are in the limelight as one of the co-generation systems which behave friendly with the environment. Fuel cells discharge both steam and hot water. Accordingly, if we combine absorption heat pump driven by waste heat with fuel cells, we can construct an advanced energy conserving system. The purpose of this study is the objective for evaluating the possibilities of effectively utilizing waste heat of fuel cells as a heat source for the single and double effect absorption systems. Simulation studies on single and double effect absorption have been performed for water/lithium-bromide pair. The effectiveness of introducing a waste heat source of fuel cells is demonstrated. The result of this study showed that total efficiency was about 85% at rated operation and about 75% at 75% load operation. Absorption cycle moved to more strong concentration when fuel cell operated at 75% load.

  • PDF

착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술 (Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition)

  • 전창덕
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.573-577
    • /
    • 2013
  • 히트펌프는 에너지 효율이 높고, 지열, 폐열, 공기열 등 다양한 열원 사용이 가능하기 때문에 보급이 빠르게 확대되고 있다. 공기를 열원으로 이용하는 공랭식 히트펌프의 경우는 실외기 표면에 형성되는 서리를 제거하기 위해 제상운전이 요구된다. 일반적으로 사용하는 역사이클(reverse cycle) 제상운전 방법은 연속난방이 불가능하며 이로 인해 성능계수가 감소하는 원인이 된다. 본 연구에서는 실외기 코일용 휜-관 열교환기를 3열로 구성하고 난방과 제상이동시에 가능하도록 일정시간 간격으로 열교환기의 한 개의 열을 응축기로, 나머지 열은 증발기로 교번 운전을 수행하여 KS C 9306에 규정된 제상-난방 시험조건(건구온도 $2^{\circ}C$, 습구온도 $1^{\circ}C$)에서 최소 180분 이상 연속난방이 가능함을 실증하였으며 역사이클 제상방법을 사용하는 일반적인 히트펌프 대비 COP가 약 20% 향상됨을 알 수 있었다.

버블 유동층과 세정 볼을 이용한 폐수 열원 히트펌프 시스템 증발기의 관 외측 오염 저감 장치에 관한 연구 (A fouling mitigation device for a wastewater heat recovery heat pump system using a bubbling fluidized bed with cleaning sponge balls)

  • 김종수;김도빈;김준하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.152-156
    • /
    • 2016
  • 폐수 열원 히트펌프 시스템은 목욕탕, 공장 또는 하천수 등을 히트펌프의 열원으로 사용한다. 증발기는 폐수로부터의 오염을 완화시키기 위하여 휜이 없는 나관식(bare tube) 열교환기가 주로 사용되고 있다. 대부분의 열 저항은 관외를 흐르는 폐수측에 생성되는 파울링에 의한 것이며, 히트펌프의 성능을 급격하게 감소시킨다. 따라서 본 연구에서는 나관식 열교환기 하부에서 버블 유동층을 형성시키고 세정 볼을 사용하여 관 외측의 파울링을 저감시키는 장치를 개발하였다. 실험 조건으로, 냉수온도 $20^{\circ}C$, 폐수 온도 $40^{\circ}C$, 관 내측 유량 100L/h, 수조 내 물의 양 50L, 열교환기 면적 $0.161m^2$ 이다. 실험결과 세정 볼 없이 버블유동층만 형성한 경우에는 버블유동층이 없는 경우에 비해 파울링에 의해 생성된 열 저항이 약 56% 감소되었으며, 세정 볼의 개수 밀도가 8,000(Number of $ball/m^3$) 일 때, 파울링에 의해 생성된 열 저항은 버블유동층 및 세정 볼이 없을 때와 비교하여 약 86% 감소되었다.

온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상 (Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse)

  • 권진경;강금춘;문종필;강연구;김충길;이수장
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.328-334
    • /
    • 2013
  • 본 연구에서는 온실 내부의 태양 잉여열과 외부의 공기열을 선택적으로 열원으로 이용함으로써 히트펌프의 성능을 향상시키고, 온실의 환기 지연을 통해 이산화탄소 시용비용을 절감할 수 있는 온실 공조시스템을 개발하고자 하였다. 본 시스템의 축열 과정은 태양 잉여열을 이용하는 내부순환모드와 외기열을 이용하는 외부순환모드가 온실 내부온도에 따라 자동으로 절환되도록 구성하였으며, 히트펌프 가동, 축열모드 절환, 난방 가동을 위한 6개의 온도값을 입력함으로써 축열과 난방이 자동으로 수행되도록 설계하였다. 단동온실을 대상으로 무환기 조건에서 기초시험을 수행한 결과, 태양 잉여열을 이용한 축열은 약 11시부터 시작되어 평균 3시간 30분 정도 유지되었으며, 주간의 온실 내부온도는 환기를 수행하지 않음에도 대부분 약 $20{\sim}28^{\circ}C$ 범위를 유지하였다. 주간 내부순환모드에서 시스템의 난방성능계수는 약 3.35로 야간 외부순환모드의 2.46 및 주간 외부순환모드의 2.67에 비해 각각 36% 및 25% 향상됨을 확인하였다. 본 시스템의 개선사항으로 태양 잉여열의 효율적 이용을 위해 축열조 관리온도를 상승시킬 수 있는 고효율 히트펌프의 적용이 필요하며, 온실의 무환기 운용에 따른 과습환경의 조성을 방지하고 태양 잉여열 수준이 높은 시기에 온실의 온도상승을 방지하기 위해 강제환기를 운전모드에 추가할 필요가 있는 것으로 판단되었다.

신재생에너지 적용이 도시열섬방지에 미치는 기여도 분석 (A Study on Quantitative Estimation for prevention of Heat Island by Using New & Renewable Energy)

  • 손원득;박정한;박경순
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.508-513
    • /
    • 2009
  • Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we use numerical model in order to analyze quantitative effects by using new & renewable energy on the heat island phenomenon in urban area. The present study quantitatively analyzes the Urban Heat Island Effects, Energy-Saving Effects, and Environmental Load Decrease Effect along New and Renewable Energy Application which is 10% of the Building Energy Consumption.

  • PDF

지열원히트펌프를 활용한 도로융설시스템의 성능 평가 및 예측 (An Evaluation and Prediction of Performance of Road Snow-melting System Utilized by Ground Source Heat Pump)

  • 최덕인;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.138-145
    • /
    • 2012
  • Because of the climate changes and the development of building technologies, the cooling loads have been increased. Among the various renewable energies, geothermal energy is known as very useful and stable energy for heating and cooling of building. This study proposes a road snow-melting system of which heat is supplied from GSHP(Ground source heat pump) in viewpoint of the initial investment and annual running performance, which is also operating as a main facility of heating and cooling for common spaces. The results of this study is as followings. From the site measurement, it is found out that the road surface temperature above the geothermal heating pipe rose up to $5^{\circ}C$, which is the design temperature of road snow-melting, after 2 hours' operation and average COP(Coefficient of performance) was estimated as 3.5. The reliability of CFD has confirmed, because the temperature difference between results of CFD analysis and site measurement is only ${\pm}0.4^{\circ}C$ and the trend of temperature variation is quite similar. CFD analysis on the effect of pavement materials clearly show that more than 2 hours is needed for snow-melting, if the road is paved by ascon or concrete. But the road paved by brick is not reached to $5^{\circ}C$ at all. To evaluate the feasibility of snow-melting system operated by a geothermal circulation which has not GSHP, the surface temperature of concrete-paved road rise up to $0^{\circ}C$ after 2 hour and 40 minutes, and it does never increase to $5^{\circ}C$. And the roads paved by ascon and brick is maintained as below $0^{\circ}C$ after 12 hours geothermal circulation.

열원조건 분석 통한 흡수식 히트펌프 적용 열에너지 네트워크의 에너지 절감 예측 (A Study on the Energy Reduction of a Heating Network Through the Application of an Absorption Heat Pump)

  • 나선익;이영수;백영진;이길봉
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.239-248
    • /
    • 2017
  • At the $21^{st}$ Conference of the Parties (COP) of the United Nations Climate change Conference, representatives of the 195 member countries reached an agreement requiring all participating countries, including Korea, to establish proactive measures to fight climate change. Under this vision, energy network technologies are deemed as a key site of research towards meeting this goal. Herein, the headquarters of the Korea Institute of Energy Research (KIER) is a worthy site for carrying out energy network technology research insofar as it contains various heat sources. To prepare for this research, a study was conducted analyzing the heat sources at KIER based on measured data. The study also consisted of developeding simulation models to predict the amount of energy savings that could be derived by replacing an absorption chiller/heater with an absorption heat pump during winter seasons. In our simulation results, we observed a primary energy saving ratio of 65~72% based on the water temperature from the heat source of a coal power plant.

히트펌프용 수직형 지중열교환기의 성능에 관한 연구 (A Study on Performance of Vertical Ground Heat Exchanger for Heat Pump)

  • 장기창;정민호;윤형기;나호상;유성연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.466-469
    • /
    • 2007
  • Heat pumps are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. And a vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double n-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF