Analysis of Oil Behavior inside Rotary Compressor Using Developed Visualization Technique

  • Cho Pil-Jae;Lee Seung-Kap;Youn Young;Ko Han-Seo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.76-83
    • /
    • 2006
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from the compressor. Thus, the analysis of the oil behavior inside the compressor is required to prevent the problem. A tested rotary compressor with visualization windows has been manufactured. in this study to investigate the oil behavior using developed visualization techniques. The oil behaviors at various operating conditions have been quantified to obtain the relationship with the outlet pressure inside the compressor. Also, the effect of the operating conditions on the quantity of the exhausted oil from the rotary compressor has been investigated using a manufactured test model.

통계적 분석을 이용한 터널 환기시스템 적정설계변수의 산정 및 적용에 관한 연구 (The Estimation and Application of Optimum Design Variables for Road Tunnel Ventilation System Based on Statistical Analysis)

  • 이보영;유용호;김진
    • 터널과지하공간
    • /
    • 제14권5호
    • /
    • pp.373-380
    • /
    • 2004
  • 본 연구에서는 도로터널 환기시설 설계기준에 의한 소요환기량 산정 시 오염물질의 기준배출량을 환경부 고시기준에 대해 산정하여 차종별, 속도별로 산정된 기준배출량을 모델터널에 적용하여 시뮬레이션 한 결과 기존의 배출량 기준 적용에 대해 소요환기량은 약 49%로 감소되었다. 또한 터널 내 유동손실로서 작용하는 변수 중 터널마찰계수와 입구저항계수 및 등가저항면적을 통계적 분석기법을 이용하여 이들 계수 중 터널의 환기량 산정에 가장 민감하게 영향을 미치는 인자가 마찰계수이며 시뮬레이션을 통해 실제 적용 가능한 계수 범위가 0.018에서 0.021의 값으로 보정될 수 있을 것으로 예상된다. 검증사례로서 4개소의 터널에 적용하였을 때, 최대 약 19.2%의 소요환기량 감소가 예상되며 이에 대해 기존의 설계운용 중인 Jet Fan 설치 대수의 산정에 있어 감소될 수 있으며, 약 연간 운용비용의 저감에 적용 가능할 것으로 사료된다.

Polypropylene과 Polyethylene으로 구성된 기공성 고분자 소재의 여과특성 (Filtration Characteristics of Polymeric Porous Materials Composed of Polypropylene and Polyethylene)

  • 안병길;오경근;최웅수;권오관
    • 청정기술
    • /
    • 제4권2호
    • /
    • pp.32-40
    • /
    • 1998
  • Polypropylene(PP)과 polyethylene(PE) 분체를 혼합하여 공기정화용 여과재로 사용하기 위한 기공성 고분자 소재를 압출 소결법으로 제조하였다. PP와 PE로 구성된 기공성 고분자 소재는 녹는점이 낮은 PE가 용융되어 PP를 결합시킨 구조임을 주사전자현미경(scanning electron microscope) 분석으로 관찰할 수 있었으며, 고분자 소재의 압출 소결시 압출기 다이 헤드의 온도, 압출 속도, PE의 용융지수 및 첨가량 변화 등에 따른 기공성 고분자 소재의 기계적물성과 여과특성 변화를 시험하였다. 일정한 압출기 헤드 다이 온도와 압출 속도하에서 압출 소결법으로 제조된 기공성 고분자 소재의 여과효율이 PE의 첨가량과는 비례 관계를 나타내었으나 PE의 용융지수에는 반비례 관계를 나타냄을 관찰할 수 있었다. 압출 소결법으로 제조된 기공성 고분자 소재의 여과특성을 시험한 결과, PP와 PE로 구성된 기공성 고분자 소재가 공기정화용 여과재로 적용될 수 있음을 확인할 수 있었다.

  • PDF

수용성 금속가공유 취급사업장에서 세균농도와 환경인자의 관계에 대한 연구 (A Study of the Relations between the Bacterial Concentration and the Environmental Factors in the Factories using Water Soluble Metal Working Fluids)

  • 박해동;박현희;김정현;장재길
    • 한국산업보건학회지
    • /
    • 제22권4호
    • /
    • pp.284-292
    • /
    • 2012
  • Objectives: The objective of this study was to investigate the relations between the bacterial concentration and the environmental factors in the water soluble metal working fluids at factories. Methods: The bacterial concentrations for airborne and fluid samples of 7 factories were quantified during the summer season. And we statistically analysed the relations between the bacterial concentrations and the factors such as temperature, relative humidity, usage quantity, mixing ratio and exchange interval. Results: The geometric mean levels of the airborne bacterial concentrations were 79.1(range : N.D.~686) $CFU/m^{3}$ and 68.1(range: N.D.~919) $CFU/m^{3}$ in the process and outdoor. The airborne bacterial concentrations showed no statistical difference by process, usage quantity, mixing ratio and exchange interval. The airborne bacterial concentrations had negatively weak correlations with air temperature and relative air humidity(p<0.05). The bacterial concentrations and pH showed significantly negative correlations in the fluids(p<0.05). And the airborne bacterial concentrations in factories and those in metal working fluids showed no statistical relationship. Conclusions: In the water soluble metal working fluids using factories, the airborne bacterial concentrations of the process were related to those of the outdoor and environmental factors, rather than the onsite contaminated metal working fluids.

실내 라돈의 오염량 감소에 관한 연구 (A study on the reduction of indoor radon contamination)

  • 김창균;최종학;강정호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.53-56
    • /
    • 2006
  • 실내 라돈 오염량을 줄이기 위한 방법을 2005년 7월부터 2005년 12월까지 6개월간 연구한 결과 가장 쉽고 효과적인 방법은 방의 창문을 자주 열어서 실내공기를 외부로 배출시키는 즉, 환기를 이용하는 것이라는 것을 알 수 있었다. 또 활성탄이 공기 중의 라돈에 대해서도 흡수가 가능하다는 사실이 증명되었기 때문에 창문을 열 수 없는 경우에는 실내에 활성탄을 비치함으로서 실내의 라돈 오염량을 상당히 감소시킬 수 있다는 결론을 얻었으나 방의 크기에 따라 비치해야하는 활성탄의 양이 어느 정도가 가장 효과적인가는 앞으로 더욱 더 연구가 필요한 것으로 사료된다.

  • PDF

대기 편광 측정을 위한 물리량 도출 및 대기 오염 물질과의 상관관계 (Deriving Physical Quantity for Measurement of Atmospheric Polarization and Its Correlation with Air Pollutants)

  • 박효건;윤형수;김은지;강동일
    • 한국지구과학회지
    • /
    • 제34권3호
    • /
    • pp.249-256
    • /
    • 2013
  • 지구 대기에서의 편광 현상을 촬영하기 위해 태양이 지평선에 걸친 순간 편광필터와 전천 카메라를 이용하여 전천 사진을 촬영하였다. 사진으로부터 편광 현상에서의 편광비와 편광폭을 정의하고 이를 측정하는 방법을 개발하였다. 편광비와 편광폭의 시계열 촬영을 통해 기상 조건에 따라 매일 달라지는 편광 현상을 정량적으로 분석할 수 있게 되었고, 이것이 기상 요소 중 대기 오염 물질과 의미 있는 상관 관계를 보이고 있다는 것을 확인하였다. 대기 편광 현상은 대기 중 대기 오염 물질의 영향을 받는데 오염 물질이 많을수록 편광비는 작아지고 편광폭은 커지는 경향을 보였다. 이는 오염 물질이 광자를 더욱 산란시켜서 편광 현상을 관찰하는 하늘의 넓은 영역으로 퍼지게 하는 효과인 것으로 추측한다.

빌딩 地下商街의 空氣性狀 및 분자의 變異原性 (Air Contamination in an Underground Commercial Floor assayed by GAseous Pollutants, Dusts and Mutagenicity)

  • 兪榮植
    • 한국대기환경학회지
    • /
    • 제3권2호
    • /
    • pp.46-52
    • /
    • 1987
  • There are many factors such as airtighteness and high density of merchandises or passengers that contaminate indoor air in underground commercial floor. So it is very important to know air quality and quantity of contamination in underground market increasing in number lately. It was from these viewpoints that gaseous pollutants, dusts and mutagenicity of organic compounds extracted from dusts in an underground market were investigatd. Organic ompounds (tar) were extracted by Soxhlet extractor with benzene as a solvent. Mutagenicities of these extracts were evaluated by the preincubation method using Salmonella typhimurium TA 100 and TA 98 strains with and without S9mix. The results obtained were as follows: It seemed to be under the influence of outdoor air that the concentrations of $CO, CO_2, NO, NO_2$ and dusts were higher in winter than summer. The concentration of $CO_2$ was higher in indoor than outdoor, but the concentration of NOx was similar in both sampling areas. Metal contents in dusts attached to the ventilation ducts were as follows showing in order of high concentration : Fe (9000-22000ppm), Zn(1200-2300ppm) and Pb (280-590ppm). The contents of tar were 6-33% of dusts, and higher than those from dusts collected by high volume air sampler. The extracts from dusts attached to the inlet duct exhibited lower mutagenicity than those from dusts attached to the outlet duct. This finding seemed to suggest that mutagenic substances were in creasing in underground. There was no seasonal difference of mutagenicity toward TA 98. Toward TA 100 in the presence of S9mix, the mutagenicity was about 3 fold higher in winter than summer. The mutagenicities of tar extracted from dusts collected by high volume air sampler were different from those attached to the ventilation ducts. The former showed 2-3 fold higher mutagenicity than the latter toward TA 100. However no difference showed between the former and the latter toward TA 98 in the absence of S9mix, but the former was 4-5 fold higher than the latter in the presence of S9mix.

  • PDF

바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성 (Characteristics of VOCs and Formaldehyde Emitted from Floorings)

  • 박현주;장성기;서수연;임준호
    • 한국대기환경학회지
    • /
    • 제25권1호
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.

The design of an ejector type microbubble generator for aeration tanks

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.307-311
    • /
    • 2019
  • The ejector type microbubble generator, which is the method to supply air to water by using cavitation in the nozzle, does not require any air supplier so it is an effective and economical. Also, the distribution of the size of bubbles is diverse. Especially, the size of bubbles is smaller than the bubbles from a conventional air diffuser and bigger than the bubbles from a pressurized dissolution type microbubble generator so it could be applied to the aeration tank for wastewater treatment. However, the performance of the ejector type microbubble generator was affected by hydraulic pressure and MLSS(Mixed Liquor Suspended Solid) concentration so many factors should be considered to apply the generator to aeration tank. Therefore, this study was performed to verify effects of hydraulic pressure and MLSS concentration on oxygen transfer of the ejector type microbubble generator. In the tests, the quantity of sucked air in the nozzle, dissolved oxygen(DO) concentration, oxygen uptake rate(OUR), oxygen transfer coefficient were measured and calculated by using experimental results. In case of the MLSS, the experiments were performed in the condition of MLSS concentration of 0, 2,000, 4,000, 8,000 mg/L. The hydraulic pressure was considered up to $2.0mH_2O$. In the results of experiments, oxygen transfer coefficient was decreased with the increase of MLSS concentration and hydraulic pressure due to the increased viscosity and density of wastewater and decreased air flow rate. Also, by using statistical analysis, when the ejector type microbubble generator was used to supply air to wasterwater, the model equation of DO concentration was suggested to predict DO concentration in wastewater.

열전소자를 이용한 배수형 전자제습기 개발 (Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element)

  • 강덕홍;김성완;김기홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF