• Title/Summary/Keyword: Air Quantity

검색결과 509건 처리시간 0.031초

국산무연탄의 소유공기량과 발생연소가스량의 산식에 관한 연구 (A Study on the Calculation Formulae for the Required Air and Combustion Gas of the Domestic Anthracites)

  • 이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.28-33
    • /
    • 1981
  • The characteristics of typical 35 kinds of domestic anthracites among 155 kinds are studied to find the calculation formula for the required quantity of air and the combustion gas quantity. 1) The author's calculation formulae are as follows: ${A_0}={\frac{1, 000}{1, 064}}{H_1}+0.086(Nm^3/kg)$ ${G_0}={\frac{1, 000}{1, 110}}{H_1}+0.234(Nm^3/kg)$(1) Theoretically required quantity of air (2) Theoretical quantity of combustion gas 2) Theoretical quantity of air in combustion of domestic anthracite is always estimated more with Rosin's formula than author's one in the typical domestic anthracites which have the lower calorific value between 3, 000-8, 000 Kcal/kg and the difference of the calculated quantity of air becomes small, as the calorific value increases. 3) Theoretical quantity of combustion gas is estimated more by author's formula than by Rosin's one with the domestic anthracites which have more calorific value than 6, 700 Kcal/kg and is estimated less in the under range of the above calorific value. 4) Theoretical quantity of required air and quantity of combustion gas of domestic anthracite show ${\pm}$4% difference by Rosin's formulae in comparison with results of actual analysis, and about ${\pm}$1.5% by the author's one.

  • PDF

Applications of Air-Foamed Stabilized Soil as Potential Subgrade Material of Railway Track

  • Park, Dae-Wook;Vo, Hai Viet;Lim, Yujin
    • International Journal of Railway
    • /
    • 제7권4호
    • /
    • pp.91-93
    • /
    • 2014
  • In these days, use of proper soils for construction materials become more limited, but wasted soils are abundant; therefore, the method which can use wasted soil such as soft clay has been investigated. Air-foamed stabilized soil has been used widely, but never been used as a subgrade material. The aim of this study is to verify the use of air-foamed stabilized soil as the subgrade construction material. Several wasted soils such as soft clay was selected to make air-foamed stabilized soil mixtures. The air-foamed stabilized mixture design was conducted to find the optimum quantity of stabilizing agent (cement) and air-foamed, and the effect of cement quantity and air-foamed quantity on strength of air-foamed stabilized soil mixtures base on the test results of unconfined compression test was investigated. As the quantity of cement is increased, the strength is increased, but the quantity of air-foamed is increased and the strength is decreased. Elastic moduli based on unconfined compression strength were obtained to use as subgrade of railway track design.

열풍건조시 적입 및 송풍량에 따른 황색종 연초엽의 이화학성 변화 (Effects of Leaf Loading Quantity and Circulating Air Volume on the Physical and Chemical Characteristics during Curing in Flue-cured Tobacco Leaves.)

  • 석영선;노재영
    • 한국연초학회지
    • /
    • 제14권1호
    • /
    • pp.48-56
    • /
    • 1992
  • This studies were carried out to investigate the effects of leaf loading quantity and circulating air volume during bulk curing on the variation of physical and chemical characteristics in flue-cured tobacco. The results are as follows : 1. The content of sugar in cured leaves was decreased with more circulating air volume and leaf loading quantity at bulk curing. 2. Total nitrogen and protein nitrogen were decreased with less circulating air volume and more leaf loading quantity, while amino nitrogen was increased. 3. The contents of linolenic acid and linoleic acid were increased with more leaf loading quantity and oxalic acid and citric acid had a tendency of being increased in case of high circulating air volume. 4. In general, major aromatic compounds were increased through flue-curing. Relatively high content of solanone in case of lower air volume and less leaf loading were observed, while megastig matrienone was increased when leaf loading was small. 5. The more circulation air volume with leaf loading quantity caused lowering equilibrium moisture content and higher shatter index, which resulted in poor quality of cured leaves based on quality index, nitrogen number, taste index phillips index, and sugar-nicotine ratio.

  • PDF

燃燒氣體의 熱力學的 平衡組成計算에 관한 硏究 (Calculation of thermodynamical equilibrium composition of combustion gases)

  • 허병기;이청종
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.177-188
    • /
    • 1987
  • 본 논문에서는 연소기체의 열력학적 평형조성 계산을 위한 수식을 Gibbs의 자 유에너지 최소화법에 의하여 유도하고 이를 컴퓨터 프로그램화하여, Table 1의 특성을 지닌 연료에 대하여 ⅰ) 연소공기량에 따른 평형조성 및 단열불꽃온도, ⅱ) 연소온도 변화에 따른 평형조성의 변화를 계산함으로써 연소기체의 생성기구를 열력학적으로 해 석하였다.

플라이애쉬 사용에 따른 콘크리트 품질변화에 관한 실험적 연구 (An experimental study on quality change of concrete according to fly ash using)

  • 박일용;백민수;손종규;최수;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.147-152
    • /
    • 1999
  • The purpose of this study is to offer foundmental information of fly ash concrete for field application. Through before study of fly ash concrete, various properties were checked. but when fly ash was added In concrete, entrained air quantity was decreased as fly ash substitution is increased in fresh concrete. so entrained air(below AE) quantity and a kind of AE according to fly ash substitution was tested basic properties. Also water-reducing efficiency was tested. And hydration heat according to fly ash substitution was tested by KR-100. As result of test, according to fly ash substitution increase, entrained air quantity is increase for target entrained air quantity, water-reducing efficiency and hydration heat are positive.

  • PDF

마이크로버블이 유화처리 정제유지류(ERCO)혼입 고로슬래그 다량 치환 콘크리트의 특성에 미치는 영향 (Effect of Micro Bubble on the High-Voiume Slag Concrete Mixed with Emulsified Refined Cooking Oil)

  • 김민영;박용준;백두환;백병훈;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2015
  • Although the carbonation problem of high-volume slag concrete has been solved by the mixed use of emulsified refine cooling oil as the pilot study, there was an instance of securing air quantity and frost resistance followed by the use of Expancel due to the problem of having vulnerability in frost resistance in result as the air quantity has not been secured. But due to the problem of Expancel not being economical, air quantity and frost resistance of high-volume slag concrete mixed with ERCO are attempted to be secured using micro bubble that can remain in the water for a long time as a relatively economical and very microscopic bubble.

  • PDF

히트 파이프의 작동유체 충전량이 성능에 미치는 영향 (Effect of Quantity of Working Fluid on Performance of a Heat Pipe)

  • 신동렬;노승탁
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.313-318
    • /
    • 1989
  • Experiments have been performed to find an optimum filling quantity of working fluid in a heat pipe. The optimum operation has been defined to give a minimum temperature difference between evaporator and condenser. The experimental results show that there exists an optimum filling quantity which is slightly smaller than that calculated by the well known formula from the geometry of the wick. When the concaved vapor-liquid interface at the wick is taken into account to calculate the required quantity of working fluid, the computed value agrees with the experimentally determined quantity.

  • PDF

A Study on the Environmental Load of Office Buildings in Seoul

  • Lee, Sang-Hyung;Lee, Yun-Gyu;Yang, Kwan-Seob;Ahn, Tae-Kyung;Lee, Seung-Eon;Park, Hyo-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.58-64
    • /
    • 2001
  • This study is to examine the emission quantity of $CO_2$ gas as the environmental load in office buildings. After the investigation of monthly consumption of each energy source(electricity and natural gas), it is analyzed that the $CO_2$ emission quantity of 34 office buildings surveyed is 22.4 kg-c/$m^2$-year, which consists of 17.5 kg-c/$m^2$-year by consurunlelectncif. and 4.9 kg-c/$m^2$-year by consuming natural gas. And the $CO_2$ emission quantity of each load in those buildings consists of 68% emitted by general electricity, 16% by cooling load and 16% by beating load. It is also proposed that the $CO_2$ emission quantity of cooling and heating load is profoundly pertinent to the variation of outdoor temperature.

  • PDF

계자 철심형 초전도 전동기 개념 설계 및 특성 해석 (Conceptual Design and Characteristic Analysis of a Superconducting Motor using Iron Cores in the Field)

  • 이상호;권순오;홍정표;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.14-18
    • /
    • 2008
  • This paper deals with the conceptual design and characteristic analysis of core type superconducting motor using iron cores in the field. As the objective function of conceptual design, the flux quantity per pole is selected. In order to reduce the quantity of superconductors, the variations of flux quantity per pole by changing the design variables and area are investigated. Finally, the quantity of superconductors between air-cored and core type superconducting motor is compared under the same motor capacity. In addition, the dimensions and volumes of motors are compared.