• Title/Summary/Keyword: Air Pollution Index

Search Result 134, Processing Time 0.025 seconds

Correlation Analysis of Atmospheric Pollutants and Meteorological Factors Based on Environmental Big Data

  • Chao, Chen;Min, Byung-Won
    • International Journal of Contents
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 2022
  • With the acceleration of urbanization and industrialization, air pollution has become increasingly serious, and the pollution control situation is not optimistic. Climate change has become a major global challenge faced by mankind. To actively respond to climate change, China has proposed carbon peak and carbon neutral goals. However, atmospheric pollutants and meteorological factors that affect air quality are complex and changeable, and the complex relationship and correlation between them must be further clarified. This paper uses China's 2013-2018 high-resolution air pollution reanalysis open data set, as well as statistical methods of the Pearson Correlation Coefficient (PCC) to calculate and visualize the design and analysis of environmental monitoring big data, which is intuitive and it quickly demonstrated the correlation between pollutants and meteorological factors in the temporal and spatial sequence, and provided convenience for environmental management departments to use air quality routine monitoring data to enable dynamic decision-making, and promote global climate governance. The experimental results show that, apart from ozone, which is negatively correlated, the other pollutants are positively correlated; meteorological factors have a greater impact on pollutants, temperature and pollutants are negatively correlated, air pressure is positively correlated, and the correlation between humidity is insignificant. The wind speed has a significant negative correlation with the six pollutants, which has a greater impact on the diffusion of pollutants.

A Study on Environmental Micro-Dust Level Detection and Remote Monitoring of Outdoor Facilities

  • Kim, Seung Kyun;Mariappan, Vinayagam;Cha, Jae Sang
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.63-69
    • /
    • 2020
  • The rapid development in modern industrialization pollutant the water and atmospheric air across the globe that have a major impact on the human and livings health. In worldwide, every country government increasing the importance to improve the outdoor air pollution monitoring and control to provide quality of life and prevent the citizens and livings life from hazard disease. We proposed the environmental dust level detection method for outdoor facilities using sensor fusion technology to measure precise micro-dust level and monitor in realtime. In this proposed approach use the camera sensor and commercial dust level sensor data to predict the micro-dust level with data fusion method. The camera sensor based dust level detection uses the optical flow based machine learning method to detect the dust level and then fused with commercial dust level sensor data to predict the precise micro-dust level of the outdoor facilities and send the dust level informations to the outdoor air pollution monitoring system. The proposed method implemented on raspberry pi based open-source hardware with Internet-of-Things (IoT) framework and evaluated the performance of the system in realtime. The experimental results confirm that the proposed micro-dust level detection is precise and reliable in sensing the air dust and pollution, which helps to indicate the change in the air pollution more precisely than the commercial sensor based method in some extent.

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

Modelling CO2 and NOx on signalized roundabout using modified adaptive neural fuzzy inference system model

  • Sulaiman, Ghassan;Younes, Mohammad K.;Al-Dulaimi, Ghassan A.
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.107-113
    • /
    • 2018
  • Air quality and pollution have recently become a major concern; vehicle emissions significantly pollute the air, especially in large and crowded cities. There are various factors that affect vehicle emissions; this research aims to find the most influential factors affecting $CO_2$ and $NO_x$ emissions using Adaptive Neural Fuzzy Inference System (ANFIS) as well as a systematic approach. The modified ANFIS (MANFIS) was developed to enhance modelling and Root Mean Square Error was used to evaluate the model performance. The results show that percentages of $CO_2$ from trucks represent the best input combination to model. While for $NO_x$ modelling, the best pair combination is the vehicle delay and percentage of heavy trucks. However, the final MANFIS structure involves two inputs, three membership functions and nine rules. For $CO_2$ modelling the triangular membership function is the best, while for $NO_x$ the membership function is two-sided Gaussian.

A Study on the Selection of Adaptable Tree in Air Pollution Area (大氣汚染地域 適應 樹種 選拔에 關한 硏究)

  • 朴晥澈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.55-65
    • /
    • 1991
  • The study was performed to select a adaptable tree species under stressed field conditions where there are a industrial plants operating with a number of smoke stacks emitting pollutants, such as hydrogen fluoride and sulfur dioxide. As a result of the study, a tree species selected are due to construct a forest belt in a zones near industrial plants to reduce the concentrations of air pollutants. The concentrations of atmospheric hydrogen fluoride and sulfur dioxide were very higher at experimental sites near industrial plants (air-pollution sites) than at control site. The leaves of 7 tree species grown at air pollution sites contained more sulfur and, specially, fluorine than at those control site. Among the tested tree species, Ligustrum japonicum Thunb. and Euonymus japonica Thunb. grown at air pollution sites did not at all break out a foliar injury but appeared to be healthy, as well as those grown at control site. Acer pseudo-sieboldianum Kom., Pinus virginiana Mill., Larix leptolepis Gordon., Pinus koraiensis Sieb. et Zucc., Pinus strobus L., Picea abies Karst and Ligustrum obtusifolium Sieb. et Zucc., however, showed a severe fluoride-type foliar injury such as necrosis on tip or margin of leaves, etc. Fluorine found in leaves was proved to be correlated to sulfur found in leaves whereas index of foliar injury hadn't a good correlation to pollutants found in leaves. It appears that Euonymus japonica Thunb., Ligustrum japonica Thunb., Platanus acerifolia Willd, Chamaecyparis pisifera Endl., Populus tomentiglandulosa T. Lee and Sophora japonica L. grown at both experimental sites had a high value of percent survival whereas Pinus virginiana Mill., Pinus koraiensis Sib. et Zucc., Koelreuteria paniculata Laxm. and Alnus hirsuta Rupr. had an extremely low value of that. In comparison with control site, the percent tree height increments in Chamaecyparis pisifera Endl., Ligustrum japonicum Thunb., Quercus acutissima Carruth., Populus tomentiglandulosa T. Lee, Pinus thunbergii Parl and Euonymus japonica Thunb. and the percent upmost root diameters in Populus tomentiglandulosa T. Lee, Chamaecyparis pisifera Endl., Euonymus japonica Thunb., Ligustrum japonicum Thunb., Betula platyphylla var. japonica Hara and Pinus thunbergii Parl. cultivated at air polluted sites showed very high value above 90%, respectively. A significant negative correlation (r=-0.662) was recognized between the index of foliage injury and the percent collective character, which was the mean of tree characters such as percent survival, percent tree height increment and percent upmost root diameter increment which compared to those at air polluted site with those at control site. Based on the percent collective character Ligustrum japonicum Thunb., Euonymus japonica Thunb., Chamaecyparis pisifera Endl., Populus tomentiglandlosa T. Lee, Betula platyphyla var. japonica Hara and Platanus occidentalis L. have large value about 90%, respectively. Therefore, the results indicate that this tree species are adaptable species in air polluted regions. For better understanding of the adaptable tree species, furthur studies concerning the effects of various air pollutants on the tree growth are required.

  • PDF

Seasonal impact to air qualities in industrial areas of the Arabian Gulf region

  • Al-Taani, Ahmed A.;Howari, Fares M.;Nazzal, Yousef;Yousef, Ahmad
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.143-149
    • /
    • 2018
  • Air quality conditions and pollution status have been evaluated in the industrial area between Sharjah and Ajman border in UAE. Daily concentrations of $O_3$, CO, $NO_2$, $SO_2$, $PM_{2.5}$, $PM_{10}$, Total Volatile Organic Compounds (TVOC) and Total Suspended Particulate (TSP) have been monitored from Sept. 2015 to April 2016. The monthly average concentrations of $O_3$, CO, $NO_2$, $SO_2$, TVOC were within the UAE ambient air quality standards during the survey period. However, $PM_{10}$ and TSP levels exceeded the recommended limits in Sept. 2015, Oct. 2015 and March 2016. Temporal variations in air quality parameters showed highest levels in March 2016 for $PM_{2.5}$, $PM_{10}$, $NO_2$, TVOC and TSP, whereas $O_3$, $SO_2$ and CO showed relatively low values in this month. $PM_{2.5}$ levels in ambient air were above the EPA guideline of $35{\mu}g/m^3$ in all months. $PM_{2.5}$ was the critical ambient air pollutant with Index for Pollutant ($I_p$) values varying from 103-209, indicating Air Quality Index categories of unhealthy for sensitive groups (62.5%) to unhealthy (25%) to very unhealthy (12.5%). The $I_p$ average values of $PM_{2.5}$ decreased from Sept. 2015 to reach lowest value in Dec. 2015 before increasing gradually, peaking in March 2016. These results suggest the potential health risks associated with $PM_{2.5}$ is low in winter, where the prevailing meteorological conditions of lower temperatures, higher humidity, higher wind speed reduced particulate matter. The results revealed the industrial area is impacted by anthropogenic and natural sources of particulate matter.

Development of Clean Air Index(CAI) for Regulatory Air Pollutants (규제대기오염물질에 대한 공기청정지수(CAI)의 개발)

  • 김창환;최금찬;전의찬;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.357-358
    • /
    • 1999
  • 대기오염에 대한 일반인의 관심이 증가되면서 이를 충족하기 위해 대기오염도 전광판, 오염 경보제, 신문 및 방송의 보고 등 여러 가지 방안이 제시되고 있다. 이들 매체를 통하여 전달되는 정보는 대개 대기오염 규제항목의 측정 실측치가 기준치와 함께 제시되어 현재 오염도가 기준을 초과하고 있는지의 여부만이 판단되고 있다.(중략)

  • PDF

Distribution of Epiphytic Lichens around Thermoelectric Power Plant (화력발전소 주변의 착생지의류 분포)

  • 김종갑;이총규;이정환;박은희;오기철
    • The Korean Journal of Ecology
    • /
    • v.27 no.3
    • /
    • pp.121-126
    • /
    • 2004
  • The purpose of this study was to investigate the distribution of epiphytic lichens that growing near the thermoelectric power plant to obtain a basic data for air environmental evaluation around the power plant. The study areas were all 12 places including ten sites near the power plant and two sites for control. All the number of lichens appeared in this study areas were 27 species. It showed to 4∼6 species within 4㎞ from the power plant, and coverage also was low. As receding from the power plant, both the number of species and overage increased. Parmelia tinctorum sensitive to air pollution did not appear within 4㎞ from the power plant, and it was regarded as the sensitive kind to air pollution. Lepraria sp.(13.40%), Parmelia austrosinensis (13.40%), and Dirinaria applanaita (13.40%) were distributed in all sites, and it could infer that they had tolerance to air pollution. The IAP (Index of Atmosphere Purity) values in Sadungdong Apsan, Seksangeabal and the Power plant were four times as low as those in Mt, Yeonwha, and it could infer that the air in those areas was not good. It was high IAP values as being distant from the power plant.

Air Pollution Tolerance Index (APTI) of Main Street Trees Following Ozone Exposure (주요 가로수 묘목의 오존노출에 따른 대기오염내성지수 비교)

  • Cho, Su Bin;Lee, Hyung Sup;Lee, Jong Kyu;Park, Sang Hee;Kim, Han Dong;Kwak, Myeong Ja;Lee, Keum Ah;Lim, Yea Ji;Woo, Su Young
    • Journal of Korean Society of Forest Science
    • /
    • v.109 no.1
    • /
    • pp.50-61
    • /
    • 2020
  • Street trees are very important to urban environments as they can alleviate air pollution. However, when ozone is absorbed through the stomata, it can induce the formation of free radicals inside the tree, negatively affecting the vegetation. The present study investigated the Air Pollution Tolerance Index (APTI) of four major street tree species: Prunus yedoensis, Zelkova serrata, Chionanthus retusus, and Pinus densiflora. Two-year-old seedlings were placed in a phytotron and fumigated with 100 nL·L-1 (ppb) ozone for 4 weeks, following which the ascorbic acid contents, chlorophyll contents, leaf pHs, and relative water contents were measured. There was no significant difference in the APTI of Prunus yedoensis and Zelkova serrata between the ozone and control treatments. By contrast, the ozone treatment caused the APTI of Chionanthus retusus to increase and that of Pinus densiflora to decrease compared with the respective controls. These results suggest that the APTI of these tree species exhibit very different responses to ozone. Therefore, more detailed research should be conducted on a range of species in the future.