• Title/Summary/Keyword: Air Operation

Search Result 2,749, Processing Time 0.024 seconds

A study on relation of position of hyoidbone and upper airway dimensional change according to chin movement in persons with skeletal class III facial pattern after orthognathic surgery (골격성 3급 부정교합자시 악교정 수술후 골격이동량에 따른 설골의 위치와 상기도 변화에 관한 연구)

  • Cho, Se-Jong;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.343-350
    • /
    • 2000
  • The goal of this study is the comparison of upper airway size and change of skeletal Class I group and skeletal Class III group (before operation, within 2 weeks after operation, 6 months after operation) respectively. At first, we measured the lines between selected upper air way landmarks on lateral cephalometric x-ray film of skeletal Class I 40 persons whoes age were 23-26 years old, ,and did the same lines of landmarks of skeletal Class III 44 persons who had not been operated yet, were within 2 weeks after operation, were 6 months after operation. And we compared it respectively and analyzed it with paired t-test. We studied the relationship of those on produced data. 1. Skeletal Class III group was narrower in nasopharyngeal air way space than that of skeletal Class I group, and increased in thickness of oropharyngeal, hypopharyngeal wall within 2 weeks after operation, and reduced in nasopharyngeal, oropharyngeal air way space, and did in thickness of nasopharngeal, hypopharyngeal wall 6 months after operation. 2. Skeletal Class III group reduced in nasopharyngeal, oropharyngeal air way space, and increased in thickness of nasopharyngeal, oropharyngeal, hypopharyngeal wall within 2 weeks after operation, restored the thickness of nasopharyngeal, oropharyngeal wall, but did not restored nasopharyngeal, oropharyngeal, hypopharyngeal air way space. 3. Vertical length from hyoid bone to mandibular plane did not have signifacant difference from Class I group but after operation, it increased more than Class I group significantly. 4. The size of airway reduced after operation. Among this, oropharyngeal airway most reduced.

  • PDF

A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System (멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘)

  • Han Do-Young;Park Kwan-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

A Study on the Operation Strategy of Radiant Floor Cooling in Apartment Buildings (공동주택에서 바닥복사냉방의 적정 운영방안에 관한 연구)

  • 조영흠;석호태;여명석;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.574-583
    • /
    • 2004
  • In this study, the operation strategy of the radiant floor cooling is evaluated in terms of indoor environmental conditions and energy consumption through simulations using the TRNSYS comparing the existing cooling operation. The operation strategy during continuously operated for cooling is proposed that a representative room had additional equipments and other rooms were operated with only a radiant floor cooling system and that system and control method for cooling are varied with period while intermittently operated for cooling. Specifically, when there are no people in the room, rooms were operated by only radiant floor cooling system using cooling storage and when people are occupied, rooms were operated by dehumidification and supplementary cooling device with radiant floor cooling system. The results of this study show that proposed operation strategy can stably maintain the set room air temperature and can reduce the energy consumption compared to the existing cooling method during continuously operated for cooling. While intermittently operated for cooling, the difference of set room air temperature by proposed operation strategy does not happen, satisfying comfort standards and the radiant floor cooling can expect to supply stable electric power because of decreasing demand for peak electric power of energy consumption.

An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients (구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구)

  • Ahn, Tae-Sub;Yang, Sang-Ill;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

Observation of Water Consumption in Zn-air Secondary Batteries

  • Yang, Soyoung;Kim, Ketack
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.381-386
    • /
    • 2019
  • Zn-air battery uses oxygen from the air, and hence, air holes in it are kept open for cell operation. Therefore, loss of water by evaporation through the holes is inevitable. When the water is depleted, the battery ceases to operate. There are two water consumption routes in Zn-air batteries, namely, active path (electrolysis) and passive path (evaporation and corrosion). Water loss by the active path (electrolysis) is much faster than that by the passive path during the early stage of the cycles. The mass change by the active path slows after 10 h. In contrast, the passive path is largely constant, becoming the main mass loss path after 10 h. The active path contributes to two-thirds of the electrolyte consumption in 24 h of cell operation in 4.0 M KOH. Although water is an important component for the cell, water vapor does not influence the cell operation unless the water is nearly depleted. However, high oxygen concentration favors the discharge reaction at the cathode.

Association of Human Error on Air Traffic Controller and Pilot (항공교통관제사와 조종사 인적오류의 연계성)

  • Moon, Woo-Choon;Choi, Youn-Chul;Yang, Han-Mo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.35-40
    • /
    • 2008
  • There are many studies indicate that human is one of the major contributing factors to the aviation accident. To this end, the Human Factor of pilots and in flight operations has been a popular subject to be studied, however, not of the air traffic controllers. Recently, some States have started studying Human Errors in Air Traffic Control field, removal of the potential errors in advance and prevention of the similar errors. This study analyzed Human Errors in air traffic control in terms of LOSA of airlines, which has been actively studied. This study will contribute to safe Flight Operation and Air Traffic Control.

  • PDF

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

The Data Compression Method for increase of Efficiency in Tactical Data Communication over Legacy Radios (Legacy Radio 기반의 전술데이터 통신 효율성 향상 위한 데이터 압축 기법)

  • Sim, Dong-Sub;Shin, Ung-Hee;Kim, Ki-Hyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.577-585
    • /
    • 2010
  • The Military Tactical Communication technology for effective network-centric warfare is developing. Targeting broadband wireless transmission, core technology for connection, and Transmission technology that secure survivability under High-speed Movement environment. On the one hand, Tactical data communication system that reflects military characteristic is developing on the base of Legacy communication equipment which is used in the field. Because almost every military units in the field have used voice to communicate which lower efficiency of operation, they have made effort to Substitute voice communication which delays military Operation Tempo to digital communication. The Communications environment of troops in Forward edge of battle field area is very poor. Especially in terms of limited frequency allocation and bandwidth. Therefore, improving the efficiency of frequency is essential for Military Tactical Communication. This paper is about The Data Compression Method for increase of Efficiency in Tactical Data Communication over Legacy Radios which are UHF, VHF, HF Radio. I proposed and proved the most efficient Data Compression Method that reflects military characteristic, after analyzing the experimentation, which simulate CAS(Close Air Support mission) data transmission between Pilot and TACP.

A Study on the Observer Training and Implementation for Effective Normal Operation Safety Survey (NOSS)

  • Choi, Jin-Kook;Choi, Se-Jong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.29 no.2
    • /
    • pp.111-116
    • /
    • 2021
  • Normal Operation Safety Survey (NOSS) is a safety management tool used by air traffic control organizations to measure data related to threats and errors to proactively prevent accidents before they occur. NOSS was developed to be applied to the air traffic control field according to the concept of Line Operation Safety Audit (LOSA) conducted by airlines to reduce human errors in the cockpits. Safety management based on data is crucial for the prevention of control-related accidents, and the competency of observers for this is important for the successful implementation of NOSS. Based on LOSA implementation experiences and expert interviews, this paper introduces the international NOSS methods and discusses the key factors required for effective observation and the implementation methods and implications of NOSS observer training.

Optimal air-conditioning system operating control strategies in summer (여름철 공조시스템의 최적 운전 제어 방식)

  • Huh, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF