• Title/Summary/Keyword: Air Monitoring Network

Search Result 157, Processing Time 0.026 seconds

Performance Evaluation of Wireless and Wired Networks for Monitoring and Control of Indoor Air Quality(IAQ) in Subway Stations (지하철역사의 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가에 관한 연구)

  • Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • In crowded subway stations indoor air quality (IAQ) is a key factor for ensuring the safety and health of passengers. Since physical variables that describing IAQ such as the concentration of particulate, $CO_2$, VOCs and biological agents need to be closely monitored and controlled in multiple locations within subway stations and in remote sites, concept of web-based monitoring and control network using both wireless and wired media needs to be implemented. Connecting remote wireless sensor network and device (LonWorks) networks to the IP network based on the concept of VDN can provide a powerful, integrated, distributed monitoring and control performance. In this study, performance of wireless and wired network in VDN for monitoring and control of IAQ in subway stations is evaluated. Specifically, delay induced in wireless and wired networks, and data transmission rate are evaluated. A key parameter is identified in assuring safety and health of passengers in subway stations.

Development of Aircargo Monitoring System using RFID Technology (RFID 기술 기반 항공화물 모니터링 시스템 개발)

  • Son, Min-Gyu;Chang, Yoon-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.3B
    • /
    • pp.474-484
    • /
    • 2010
  • In this paper, we introduce a RFIDbased real time air cargo monitoring system for cargo management in the air cargo terminal. In order to construct functional requirement and development framework,. we have analyzed the user requirements of cargo personnel of Incheon International Air Cargo Terminal. To find out the possibilities to adopt RFID in the cargo, we had benchmarked different RFID systems and also tested radio environment of the cargo. Based on the RFID system test and radior environment test, we developed a web based cargo monitoring solution which adopts EPC network and BPM solution with flexibility and expandability.

Algorithm for Determining Aircraft Washing Intervals Using Atmospheric Corrosion Monitoring of Airbase Data and an Artificial Neural Network (인공신경망과 대기부식환경 모니터링 데이터를 이용한 항공기 세척주기 결정 알고리즘)

  • Hyeok-Jun Kwon;Dooyoul Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.377-386
    • /
    • 2023
  • Aircraft washing is performed periodically for corrosion control. Currently, the aircraft washing interval is qualitatively set according to the geographical conditions of each base. We developed a washing interval determination algorithm based on atmospheric corrosion environment monitoring data at the Republic of Korea Air Force (ROKAF) bases and United States Air Force (USAF) bases to determine the optimal interval. The main factors of the washing interval decision algorithm were identified through hierarchical clustering, sensitivity analysis, and analysis of variance, and criteria were derived. To improve the classification accuracy, we developed a washing interval decision model based on an artificial neural network (ANN). The ANN model was calibrated and validated using the atmospheric corrosion environment monitoring data and washing intervals of the USAF bases. The new algorithm returned a three-level washing interval, depending on the corrosion rate of steel and the results of the ANN model. A new base-specific aircraft washing interval was proposed by inputting the atmospheric corrosion environment monitoring results of the ROKAF bases into the algorithm.

A Commentary on Air Pollution Monitoring Programs in Korea

  • Ghim, Young-Sung;Kim, Jin-Young;Shim, Shang-Gyoo;Moon, Kill-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.21-28
    • /
    • 2002
  • Air quality issues in Korea rapidly changed at the beginning of the 1990s from primary to secondary pollutants starting in Seoul, the capital of Korea. The present frame of national air pollution monitoring networks was established between the end of the 1980s and the beginning of the 1990s. Background monitoring was initiated in the middle of the 1990s in response to increasing public concern about the long-range transport of air pollutants. Apart from the national monitoring, both routine and intensive measurements of fine particles have been made for research purposes since the middle of the 1990s at several background sites. However, air pollution monitoring in urban areas for other purposes was relatively scarce as national monitoring has been concentrated in these areas. Although ozone pollution has become a significant issue in major metropolitan areas every summer, only a little information on ozone precursors is available. During the past few years, the number of national monitoring stations has greatly increased. The government has a plan to gradually expand monitoring items as well as stations. It is anticipated that highly detailed information on both photochemical reactants and products will be available within the next several years. More emphasis will be placed on toxic substances based on risk assessment in monitoring for both research and policy making.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

Design and implementation of flooding-based query model in wireless sensor networks for indoor environmental monitoring system (실내환경 모니터링시스템을 위한 무선 센서네트워크에서의 플러딩 방식의 질의모델 설계 및 구현)

  • Lee, Seung-Chul;Jung, Sang-Joong;Lee, Young-Dong;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.168-177
    • /
    • 2008
  • An indoor environmental monitoring system using IEEE 802.15.4 based wireless sensor network is proposed to monitor the amount of pollutant entering to the room from outside and also the amount of pollutant that is generated in indoor by the building materials itself or human activities. Small-size, low-power wireless sensor node and low power electrochemical sensor board is designed to measure the condition of indoor environment in buildings such as home, offices, commercial premises and schools. In this paper, two query models, the broadcasting query protocol and flooding query protocol, were designed and programmed as a query-based routing protocol in wireless sensor network for an environment monitoring system. The flooding query routing protocol in environment monitoring is very effective as a power saving routing protocol and reliable data transmission between sensor nodes.

A Study on Establishment of Emission Gas Monitoring System for Major Port Cities (주요 항만도시의 배출가스 모니터링 시스템 구축방안 연구)

  • Kim, U-Seon;Cheon, Min-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.55-56
    • /
    • 2018
  • In order to construct an efficient monitoring system for major port cities in Korea, the first step to build and manage related laws and institutional infrastructure with strengthen the cooperation of the relevant agencies, regional port authorities, and port corporations. Second, for the management of air pollutants emitted by ports, a management system should be established through systematic inventory source inventory and real-time monitoring system. Third, active countermeasures should be established to reduce the emission of air pollutants by sources such as ships, harbor equipment, and trucks. This will improve the air quality of major port cities and move them to clean port cities.

  • PDF

A Study on the Concentration Analysis of Roadside Air Pollutants

  • CHOI, Jong-Sun;JUNG, Min-Jae;LEE, Jun-Cheol;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.2
    • /
    • pp.35-41
    • /
    • 2021
  • Purpose: In this study, volatile organic compounds(VOCs) and aldehydes generated from roadside vehicles and other pollutants were measured and analyzed. Research design, data and methodology: As a result of measuring and analyzing three areas near the roadside, Vinyl chloride 0.00 ~ 0.02 ppb, Benzene 2.87 ~ 5.01 ppb. Toluene 4.51 ~ 8.62 ppb, Styrene 0.00 ~ 0.34 ppb, Formaldehyde 8.45 ~ 17.12 ug/m3, Acetaldehyde 7.01 ~ 17.64 ug/m3 were detected. When comparing the analysis results and the 6-month average concentration of the hazardous air monitoring network, the analysis results were about 26 times higher for Benzene, about 5 times for Toluene, and about 3.75 times for Styrene. In the case of vinyl chloride, it was confirmed that it was about 20 times lower than that of the hazardous atmosphere monitoring network. Results: Therefore, it is necessary to reexamine the installation location of the measurement network because people are exposed to pollutants on the actual roadside. It is judged that it is right to build a measurement network that is practically helpful to people by increasing the measurement items in the measurement network.