• Title/Summary/Keyword: Air Management

Search Result 2,612, Processing Time 0.032 seconds

Construction of Environment Management System Based on ubiquitous (유비쿼터스기반의 환경 관제 시스템 구축)

  • Jeong, Chang-Won;Jang, Hyung-Geun;Joo, Su-Chong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.195-204
    • /
    • 2010
  • In this paper, we propose an efficient indoor environment management system which provides the environment management service in ubiquitous computing environment. It is designed to gather data from the user's environment and keep it pleasant with respect to indoor air quality regulation. In order to offer such service Ubiquitous Computing Environment used distributed framework based on the active model for its development and support, while supporting service integration and also we used service oriented architecture. In order to verify the performance of the environment management system, components showed operation while environment management service showed the result through GUI screen.

Drug distribution management system based on IoT

  • Liu, Zeliang;Zhang, Chunmei;Peng, Hui;Xu, Qin;Gao, Yubao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.2
    • /
    • pp.424-444
    • /
    • 2022
  • In hospitals and pharmacies, the distribution of medicines is an important part. Any mistakes, misses, fake medicines and expired medicines can cause medical accidents. With the widespread application of the Internet of Things technology (IoT), traditional drug distribution methods need to be upgraded. This article proposes a drug distribution management scheme based on the Internet of Things technology. In the production of drugs, a flexible RFID tag was printed on the packaging box, which stored a series of information such as drug name, dosage, raw materials, efficacy, production date, expiration date, and manufacturer. The use of a drug distribution management system combined with RFID readers can identify drug information and effectively prevent the occurrence of erroneous, missed, counterfeit, and expired drugs. It can also improve management efficiency, reduce management costs, and control management risks. Through the circuit design and software system development, the test results show that this solution is effective and feasible, the proposed method can achieve the expected results.

A Study on Green Space Management Planning Considering Urban Thermal Environment (도시 열환경을 고려한 녹지관리방안 수립 연구)

  • Joo, Chang-Hun;Kim, Jeong-Ho;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1349-1358
    • /
    • 2014
  • This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type I-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, type II-1, development condition of wind road is incomplete as IIlevel, entering cold air is difficult and thermal management and improvement is needed area. Type III-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type III-2 is revealed as smaller scale than III-1, and small area of origin of cold air. Type IV, anthropogenic heat is $81{\sim}150W/m^2$, average, but development function of wind road is very favorable. Type V, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as II level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type I-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type II-1 afforestation in site and goal biotops area ratio 40%, type III-1, preservation plan to display the current function continuously is requested. Type IV suggests afforestation of stream current, and type V suggests quantitative increase of green space and goal biotops area ratio 45%.

Variations and Trends in Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) in Air (대기 중 다환방향족 탄화수소류의 오염도 변화 특성)

  • Chung, Yong;Park, Seong-Eun;Hwang, Man-Sik;Hong, Ji-Yeon
    • Environmental Analysis Health and Toxicology
    • /
    • v.13 no.1_2
    • /
    • pp.43-53
    • /
    • 1998
  • Ambient air levels of polycyclic aromatic hydrocarbons(PAHs) are of concern because of their potential for adverse health effects including transformation of some of these substances to mutagens and carcinogens by mammalian microsomal enzyme system. Airbone particulate samples were collected by a conventional high-volume sampler and by an Anderson cascade impactor on 2 to 3 days in each month over a period of 1 year at a representative site of the heavy traffic area of Seoul from beptember 1994 to August 1995. Ten individual PAHs in sizable air particulates of each stage of two months were separated and analyzed by gas chromatography/mass spectrometry. As a results of analysis, the gross concentrations of PAHs in the fine and coarse particles were higher in the winter month than in the spring, followed in descending order by in the fall and summer. In a study of dependency of 10 PAHs compounds on size distribution of particles at heavy traffic area found that about 85% of the total PAHs content was associated with particles less than 2.0um (fine particles) in diameter of winter sampling period. while 79% were associated with this size fraction during summer period. In according to the mean concentrations of the 10 PAHs in 7 size classification from < 0.38 to> 10.1, the 'size was the smaller, PAHs concentration was the higher. Thus it was found that PAHs concentration was greatly affected by air particle size. Annual mean benzo(a)pyrene equivalents was 5.88ng/m$^3$ and obtained by applying, toxic equivalency factor developed by Nisbet and Lagoy.

  • PDF

Analysis of Impact Factors on the Variation of PM10 Concentration in Seoul, Korea - Focus on PM10 Concentration Measured in 2003, 2004 -

  • Song, Hyung-Do;Lee, Hee-Chul;Kwon, Chun-Kyoung;Kim, Rhok-Ho;Kim, Sang-Kyun;Lee, Jae-Bum
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • To identify the primary factor affected the decreased $PM_{10}$ concentration in Seoul which is the capital city of Korea, wind speed and emissions in 2003 and 2004 were analyzed. The level of air pollution is intense in Seoul and continually increased since the late 1990s. However the concentration of $PM_{10}$ has been greatly declined recently. In particular, the concentration of $PM_{10}$ decreased 14% in 2003 and 2004 excluding the Asian dust periods. It is suggested that the major factors for the decrease are differences in wind speed between the two years and the period of constant breeze. In 2003, intense Asian dust events happened frequently and it increased the concentration of total $PM_{10}$. The intense dust events were influence by the speed and duration of the wind. It is considered that the meteorological condition was the primary drive for the change of the concentration of $PM_{10}$. The decreased emissions seem to be the additional factor for the change in the concentration of $PM_{10}$.

Factors Affecting Acer mono sap Exudation : Kwangyang Region in Korea (고로쇠나무 수액의 출수에 미치는 영향 인자 분석 : (I) 광양지역)

  • Choi, Won-Sil;Park, Mi-Jin;Lee, Hak-Ju;Choi, In-Gyu;Kang, Ha-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.66-74
    • /
    • 2010
  • This study was carried out to investigate the optimum condition for sap exudation of Acer mono Max. tree in a site of Mt. Baekun, Kwangyang city, Korea. Amount of sap exudation, air temperature, relative air humidity and tree diameter at breast height (DBH) were monitored for the period of January 5 through March 28, 2008, and correlation analysis of several factors affecting on sap exudation was carried out. As the diameter of Acer mono at breast height increased, the amount of sap was linearly proportional. Sap exudation initiated at February 18, and occurred intensively in the period of February 28 through March 10, resulting in 84% of total sap amount by volume. During sap exudation, the minimum temperature was averaged at $-2.4{\pm}1.5^{\circ}C$ and the maximum at $6.0{\pm}1.8^{\circ}C$, while there was no sap exudation whenever temperature was below or above $0^{\circ}C$ all the day long. The maximum temperature, range of temperature and the maximum, minimum and mean humidities in air were significant factors affecting on amount of sap. The maximum air temperature had the highest correlation coefficient with 0.768 (P < 0.01) and was also considered as the principal factor by partial-correlation analysis. These results showed that sap exudation required daily air-temperature fluctuation from below to above $0^{\circ}C$, and the amount of sap was strongly dependent on the highest daily-temperature and DBH of tree.