• Title/Summary/Keyword: Air Machinery

Search Result 1,163, Processing Time 0.038 seconds

Vacuum system design of a 10 ton/day class air liquefaction cold box for liquid air energy storage

  • Sehwan, In;Juwon, Kim;Junyoung, Park;Seong-Je, Park;Jiho, Park;Junseok, Ko;Hankil, Yeom;Hyobong, Kim;Sangyoon, Chu;Jongwoo, Kim;Yong-Ju, Hong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.65-70
    • /
    • 2022
  • A vacuum system is designed for thermal insulation of a 10 ton/day class air liquefaction cold box for liquid air energy storage. The vacuum system is composed of a turbomolecular pump, a backing pump and vacuum piping for the vacuum pumps. The turbomolecular pump is in combination with the backing pump for pumping capacity. The vacuum piping is designed with system installation conditions, such as distance from the cold box, connections to vacuum pumps and installation space. The capacity of the vacuum pump combination, namely pumping speed, is determined by analysis of the vacuum system, and pump-down time to 1×10-5 mbar is estimated. Vacuum piping conductance, system pumping speed and outgassing rate are calculated for the pump-down time with the ultimate pumping speed range of the vacuum pump combination of 1400 - 2300 l/s. Although the pump-down time gets shorter by larger capacity vacuum pumps, it mainly depends on target vacuum degree and outgassing rate in the cold box. The pump-down time is estimated as 3 - 6 hours appropriate for cold box operation for the pumping speed range. Considering the outgassing rate has uncertainty, the vacuum pump combination with pumping speed of 1900 l/s is chosen for the vacuum system, which is middle value of the pumping speed range.

Drying Characteristics of Oak Mushroom Using Conveyer Far Infrared Dryer - Down Draft Air Flow Type - (컨베이어 원적외선 건조기를 이용한 표고버섯의 건조특성 - 하향 송풍방식 -)

  • 연광석;김민호;한충수;조성찬;강태환;이해철;김창복;김진국
    • Journal of Biosystems Engineering
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2004
  • This study was conducted to develop a new drying method far reducing the drying cost and time and to investigate the drying characteristics of oak mushroom. A far infrared dryer of down draft air flow type used for this experiment can control the drying parameters, such as far infrared heater temperature and aeration velocity. The far infrared drying tests were performed at aeration velocities of 0.3 and 0.6m/s under the temperature of 90 and 100$^{\circ}C$ in for infrared heater, respectively. The results were compared and analyzed with those of an heated air drying method used as a control in terms of properties representing the drying characteristics. such as shrinkage rate, color, energy consumption amino acid components, drying rate and moisture ratio. The results obtained from this research can be summarized as follows. 1. The drying rate of far infrared drying was faster than that of heated air drying. With high temperature of far infrared heater and slow aeration velocity, the far infrared drying of down draft air flow type was superior to the heated air drying. 2. Most of far infrared drying conditions required less energy consumption than heated air drying. 3. The shrinkage rates of heated air drying and far infrared drying were decreased by 17.0% and 18.2∼19.8%, respectively. 4. The difference of color on oak mushroom surface before and after drying can be represented as $\Delta$E. $\Delta$E values of far infrared drying and heated air drying were 2.39∼4.55 and 6.77, respectively. 5. The amounts of free amino acids were higher in the far infrared than in the heated air drying. In addition the amounts of Gln and Glu generally were increased and those of Ala, Leu, and Val were decreased in order.

Pressure Drop Characteristics of Air Particle Flow in Powder Transport Piping System (파우더 수송시스템의 공기입자 유동 압력강하 특성)

  • Kim, Jong-Soon;Chung, Sung-Won;Kwon, Soon-Gu;Park, Jong-Min;Choi, Won-Sik;Kwon, Soon-Hong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.157-168
    • /
    • 2017
  • The pressure drop characteristics of air particle flow in a powder transport piping system were analyzed in this study. The pressure drop characteristics of air particle flow in the piping system have not well understood due to the complexibility of particle motion mechanism. Particles or powders suspended in the air flow cause the increase of the pressure drop and affect directly transport efficiency. In this study, the pressure drop in a powder transport piping system was analyzed with interactions of air flow and particle motion in straight and curved pipes. The total pressure drop increased with pipe length, mixture ratio, and friction factor of particles because of increased friction loss of air and particles in the piping system. For the coal powders of $74{\mu}msize$ and powder-to-air mass mixture ratio of 0.667, the total pressure drop under the consideration of powders and air flow was calculated as much as 30% higher than that air flow only.

Analysis of Air Pollutant Emissions from Agricultural Machinery in South Korea (국내의 농업기계에 의해 배출되는 대기 오염 물질 분석)

  • Shin, Chang-Seop;Park, Tusan;Hong, Dong-Hyuk;Kim, TaeHan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.14-25
    • /
    • 2019
  • From 2019 onwards, more stringent regulations (from Stage 4 to Stage 5) are to be implemented in Europe in order to reduce the air pollutant emissions. In South Korea, the government authorities started to make new regulation to meet the European regulation. As a first step, the air pollutant emissions such as CO, NOx, SOx, TSP, $PM_{10}$, $PM_{2.5}$, VOC, $NH_3$ by agricultural machinery were analyzed based on CAPSS inventory along with the analysis in the general aspect in this study. Three levels of analysis was conducted each in agricultural machinery aspect along with in the general aspect. Per agricultural tractor, all kinds of the air pollutant emissions decreased by 25, 25, 99, 25, 25, 25, 25% for the CO, NOx, SOx, TSP, $PM_{10}$, VOC, $NH_3$ emissions each from the year 2000 to the year 2014. Per combine harvester, all kinds of the air pollutant emissions decreased by 63, 63, 91, 63, 63, 63, 63% for the CO, NOx, SOx, TSP, $PM_{10}$, VOC, $NH_3$ emissions each from the year 2000 to the year 2014.

Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption (에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석)

  • Han, Bangwoo;Kang, Ji-Su;Kim, Hak-Joon;Kim, Yong-Jin;Won, Hyosig
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2 (지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교)

  • Lee, Gunhee;Kim, Sang Bok;Park, Inyong;Hong, Kee Jung;Lee, Yeawan;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

Development of Air Cushion Transporter Using the Pneumatic Floating Pad (공기부양판을 적용한 에어쿠션 트랜스포터의 개발)

  • Jung, Hyunmok;Hong, Junhee;Yun, Dongwon;Park, Heechang;Kim, Byungin;Lee, Sunghwi
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.338-344
    • /
    • 2016
  • Recent trends in transport system for carrying heavy freight are that demands of a high efficiency, economic efficiency, convenience and safety are increased. Conventional transport systems were poor in transport efficiency and economic efficiency. And Safety problems can be caused to products and workers. In order to overcome these problems, an air cushion transport device with a high-pressure air is required. The air cushion transporter is a device for reducing the frictional force of floor surface and lifting the heavy freight by spraying the high-pressure air to the floor. Technology to float and transfer freight using high-pressure air is very convenient and initial cost can be reduced. In this paper, the study on the levitation performance and transport efficiency of air cushion transport system is conducted and verified that air cushion transporter has a significantly higher transport efficiency than conventional heavy handling systems.

Experiments for Pressure Drop of Scrubbing Layer in a Scrubber System (스크러버 내 충진층에서의 압력강하 특성에 관한 실험적 연구)

  • Yong-Shik Han;Kyu Hyung Do;Kyungyul Chung;Byungil Choi;Hwalong You;Changhyun Kim;Minchang Kim;Taehoon Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.3
    • /
    • pp.186-192
    • /
    • 2023
  • According to the regulation on the pollution of the marine environment, SOx emission from ships has to be reduced. A SOx scrubbing system installed in a funnel of a ship is considered in order to reduce SOx emission. A scrubbing layer with a porous material is present in the funnel to increase the contact area between exhaust gas and water. In this study, experiments on the pressure drop characteristics in the scrubbing layer are conducted to investigate the effect of the scrubber on the engine load. The pressure drop according to flow rate of air instead of exhaust gas was measured for fillers such as sphere, pall ring and saddle in the scrubbing layer. First of all, porosity is experimentally measured for the three types of filler and it is confirmed that the porosity of the saddle-type filler was the largest. The pressure drop according to the change in air flow rate was measured for the three types of fillers in the scrubbing layer. As a result, the pressure drop was the smallest in the scrubbing layer with the saddle-type filler which has the largest porosity. In addition, the effect of spraying water flowing counter flow against air flow is experimentally examined. It is known that the pressure drop is increased because the air flow space is reduced when water is sprayed. In the case of the saddle, the pressure drop is about 1.5 to 2 times greater than that when only air flows at the optimum exhaust gas-water injection ratio.

Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units (에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교)

  • Shin, Dongho;Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.