• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.024 seconds

Knowledge of Modern housing of the Textbooks for Physiology and Hygiene in Korea 1894-1910 (생리 및 위생분야 교과용도서의 근대적 주거지식(1894-1910))

  • Kim, Myung-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1328-1333
    • /
    • 2008
  • The new knowledge in the textbooks for Physiology and Hygiene in Korea 1905-1910 was focused on the problems of hygiene. Lighting, ventilation, dryness were proposed as main conditions fer hygienic housing, for which management and planning methods were explained. This knowledge was taught as 'scientific' or 'modern' knowledge based on the physiological theory and air property, thereafter the conditions were placed as important conditions of modern housing.

A Survey of the Air Quality in Underground Environment (지하환경의 대기오염물질 규제에 관한 조사연구)

  • Lee M. H.;Han E. J.;Shin C. K.;Chung H. D.;Han J. K.
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.47-58
    • /
    • 1986
  • The underground living spaces have become one of the major environment of this decade in urban area. This study was carried out to examine contamination level for purpose of preservation of the pleasant underground environment. Three subway stations and three underground shopping centers in Seoul and two underground shopping centers in Busan were selected and surveyed by measuring gaseous pollutants $(SO_2,\; NO_2,\;CO,\;HC,\; HCHO,\;CO_2)$, dust, airborne microbes, and the other air condtions (temperature, humidity, air pressure, air flow, kata cooling power). These examined data were compared with four kinds of standard (building sanitation management, room air quality standards, occupational safety and health standards, ventilation equipment) as environmental hygiene.

  • PDF

A Subjective Symptom Level and Satisfaction Factor by Indoor Air Quality According to Ventilation System in Dental Clinic (치과병·의원 환기방법에 따른 실내공기질 자각증상 수준 및 근무환경 만족요인)

  • Choi, Mi-Suk;Ji, Dong-Ha;Choi, Jae-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.353-359
    • /
    • 2011
  • This study was designed to identify a subjective symptom level by Indoor air according to ventilation system in Dental Clinic. The number of respondents was 582 who work in dental clinic and period of investigation was October 2010 through January 2011. A structured questionnaire was employed to evaluate the level of participants' sociodemographics, job-related factors, work place condition, a subjective symptom. Most of respondents were answered that time for symptom to begin was at around 2 P.M. and time for symptom to feel serve pain was at around 3 P.M. and ventilation frequency per a day was often in case of individual cooling and heating system. More often natural ventilation and in case of individual cooling and heating system, the level of subject symptom was low and multiple regression analysis has found that indoor air quality related elements were main factors that influence to the feeling of satisfaction in work place. The results of this study suggest that more often natural ventilation was very important to reduce the level of subjective symptom. Thus, a management program for indoor air quality is strongly recommended by natural ventilation, maintenance man for promotion of quality of life in dental hygienist and to improve dental service and competitiveness.

Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process (반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템)

  • Choi, Kwang-Min;Lee, Ji-Eun;Cho, Kwi-Young;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

A Study on Airborne Microorganism in Hospital (일부 병원 실내에서의 공기중 미생물 오염에 관한 연구)

  • Jung, Sun Hoi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.231-241
    • /
    • 1998
  • To assess biological indoor air quality in hospital, concentrations of viable airborne microbes were determined at intensive care unit(ICU), patient room (PR), outpatient waiting room(OPWR) in hospitals of large(1000 beds), middle(500 beds), small(100 beds) hospitals, respectively. Gram positive bacteria, gram negative bacteria, fungi were sampled using suctional sampling method by RCS sampler (Reuter centrifugal air sampler) and RCS GK-A agar plate. In gram positive bacteria groups, CNS(Coagulase Negative Staphylococcus), Micrococcus, Lactobacillus, S. aureus, Enterococcus, St. viridans identified. In gram negative bacteria groups, A. baumannii, Kl. peumoniae and E. coli were identified, and Penicillium was identified in fugi groups. Results of the study were as follows. 1. The highest concentrations of airborne microbes was $971CFU/m^3$ at 5:00 PM in small hospital patient room, and average concentrations of airborne microbes in large, middle and small hospitals were $282CFU/m^3$, $289CFU/m^3$ and $625CFU/m^3$, respectively. Average concentrations of airborne microbes in office(control) was $90CFU/m^3$. Thus, the small hospital showed the worst condition. 2. Representatives of 8 different genera were identified in 150 samples. The most frequently isolated organisms were Staphylococcus (73.0%), Micrococcus (20.7%) and Lactobacillus (4.7%), respectively. Pathogenic microbes isolated were A. baumannii, E. coli, Enterococcus, Kl. peumoniae, S. aureus, St. viridans and Penicillium as fungi. In office, no pathogenic microbes were identified. Average concentrations of airborne pathogenic microbes in large, middle and small hospital were $5CFU/m^3$ (2%), $11CFU/m^3$ (4%) and $12CFU/m^3$ (2%), respectively. Thus, condition in a large hospital was better than those in a middle and a small hospital.

  • PDF

Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment (건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대)

  • Roh, Young-Man;Lee, Cheol Min;Kim, Yoon Shin;Kim, Seok Won;Kim, Chi-Nyon;Kim, Hyun-Wook;Cho, Kee Hong;Choi, Ho Chun;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

A Case of Workers' Exposure Reductions for Chemicals in a Polyurethane Pad Process through the Substitution of Raw Materials (폴리우레탄 패드 공정에서의 원료물질 대체에 따른 근로자 노출저감 사례)

  • Jang, Jae-Kil;Park, Hyunhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.281-292
    • /
    • 2014
  • Objectives: The aim of this case study is to verify the chemical exposure reductions for various chemicals by substituting the ingredients of raw materials in a polyurethane(PU) foaming industry. The PU foaming process was making various passenger car seats from chemicals such as toluene diisocinate(TDI), methylene bisphenyl isocyanate(MDI) and polyols. Methods: Basic process data and workers' health effects could be gathered by interviewing managers and reviewing previous exposure monitoring data. Amine, aldehyde and isocyanate chemicals were analyzed following the NIOSH-NMAM. Area sampling methods rather than personal sampling were introduced for this field investigation. Results: Two amines, triethylene diamine(TEDA) and N,N,N',N'-Tetramethyl-1,6- hexanediamine(TMHDA) were identified in raw polyol, cured PU foam and air. The average concentrations of TEDA and TMHDA showd less than 1 ppm by area sampling; however, that caused halovision among workers in PU-PAD process. Aldehydes and isocyanates were detected in the air while the concentrations were relatively low compare to occupational exposure limits. Successful raw material substitution from nonreactive amine to reactive amine could reduces air-borne amine and aldehyde levels by about 70%. Halovision had been disappeared successfully in the process. Conclusions: Several amines caused halovision among workers in PU-PAD process, especially during summer season in spite of relatively low levels. Combination of reactive amines into urethane foam could reduced vapor generation into air, which resulted in the elimination of eye troubles in the process.

Exposure Assessment of Volatile Organic Compounds for Workers Handling Rust-preventive Oils (방청유 취급 근로자의 휘발성 유기화합물 노출 평가)

  • Jeong, Yoonkeong;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.23-37
    • /
    • 2017
  • Objectives : This study was conducted to evaluate the level of exposure to volatile organic compounds (VOCs) among workers handling rust preventive oils. Methods : A total of 30 bulk samples and 54 personal air samples were collected using diffusive samplers at 22 workplaces handling rust preventive oils in Daegu and Gyongsangbuk-do Province from March to October 2013. We also investigated detailed information on the related work conditions, such as kinds of products, handling methods, local exhaustive ventilation systems, and the status of the wearing personal protective equipment. All bulk samples and air samples were analyzed using gas chromatography mass spectrometry (GC-MS) to identify components to which workers potentially were exposed. Quantitative airborne concentrations of VOCs were confirmed using gas chromatography with flame ionized detectors. Results : In terms of qualitative analyses for the 30 bulk samples, we found carcinogenic, mutagenic and reproductive toxic(CMR) substances such as butane(carcinogenic Group 1A, mutagenic Group 1B), butoxy ethanol(carcinogenic Group 2), cumene (carcinogenic Group 2), ethyl benzene(carcinogenic Group 2), methyl isobutyl ketone(carcinogenic Group 2) and toluene (reproductive toxic, Group 2). As a result of full-shift based personal air samples, eight substances such as n-hexane, n-heptane, octane, nonane, decane, toluene, ethyl benzene and xylene were detected. Among them, n-hexane and n-heptane were detected in all of 54 air samples with $13.13mg/m^3$ and $8.61mg/m^3$ of maximum concentration, respectively. The level of airborne concentration from all of samples were bellow the occupational exposure limit in Korea. Conclusions : Based on the results of this study, workers handling rust preventive oils could be exposed to CMR substances contained in rust preventive oils and n-hexane and n-heptane were found as the most frequent sources of VOC exposure.

Metal Concentrations Analysed in the Inorganic Bulk Pigment Samples by ICP-AES and the Provision Rate of MSDS and Agreement Rate with MSDS (우리 나라에서 제조/사용하는 일부 무기 안료중 ICP-AES를 이용한 주요 중금속 농도와 MSDS 비치율 및 일치율 비교)

  • Kim, Hyoung-Ah;Lee, Kyoung-Joo;Kim, Yong-Woo;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.196-208
    • /
    • 1998
  • To improve the quality of environmental measurements and evaluation of the workplace air in the pigment manufacturing industries, we analyzed metal(chromium, cadmium, lead, iron, cobalt, manganese, antimony, titanium, arsenic, and selenium) concentrations by ICP-AES in sixty seven samples of inorganic bulk pigments which are produced and/or used in Korea. We also collected MSDS which has to be supplied by manufacturer and/or supplier and posted in the workplace according to the Hazard Communication Standards, and compared the number of metals listed in each MSDS with the number of metals determined by ICP-AES. Results were as followed; 1. Among seventeen yellowish-colored samples, chromium(2~19%) and lead(0.1~61%) were the two major metals. In thirteen reddish-colored samples, iron was the major component with 37~81%. Cobalt and manganese were detected in blue-colored samples with less than 1%, while antimony and titanium were the major two metals in white-colored pigments with 178~300 ppm and with 36~65%, respectively. 2. In area samples collected in workplace air(one pigments producing factory and five retailer stores), iron and manganese were detected but the concentrations not exceeded the TLVs(1 and $5mg/m^3$, respectively). In three of fifteen samples, the concentrations of lead exceeded the TLV ($0.05mg/m^3$). 3. Two out of seven companies provided MSDS, and the average provision rate was 22.4%. And the coincidence rate of the number of metals referenced in MSDS and determined by ICP-AES mostly accorded, but in one sample, different metal was detected from MSDS. In summary, metals have to be concerned in evaluation of the workplace air dealing with compounds of inorganic pigments dust are cobalt, chromium, iron, manganese, lead and antimony, and these are simultaneously determined by ICP-AES. Taking this opportunity, it is needed to reinforce that the personnel is to be concerned about prevention of workers' ill health regarding to provision of MSDS.

  • PDF

The Factor Analysis of Airborn Fiber Concentrations at Parking Lots in Seoul (서울 시내 일부 주차장의 공기중 섬유농도에 영향을 미치는 인자 분석)

  • Moon, Ji Young;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.157-167
    • /
    • 1994
  • This study was conducted to analyze the relationship between the types of fiber and its content and the levels of airborne fiber concentrations at eight parking lots where sprayed insulation material was found on the walls and ceilings. Also this study was designed to find the relationship between the levels of airborne fiber concentrations and such variables as air current, humidity, total exhaust volume, surface condition of insulation material and building age. The results obtained were as follows : 1. No significant correlation was found between the levels of airborne tiber concentration and the building age, air current, humidity, total exhaust volume, space and the number of traffics. 2. A significant correlation was found between the levels of airborne fiber concentration and the MMMF content of the insulation material(r=0.7594). However, no significant correlation was found between the levels of airborne fiber concentration and total fiber content of insulation material. 3. The differences of the airborne fiber concentrations among Cateogory 1, 2 and 3 classified by the degrees of surface insulation material maintenance were very significant. 4. Two bulk samples contained 30% crodicolite and 1% anthophylite. The MMMFs, in all parking lots, included mineral wool, cellulose fiber, trace cellulose fiber, trace tiber glass and vermiculite. 5. The mean value and the range of airborne fiber concentrations at 8 parking lots were $0.0239{\pm}0.0095f/cc$ and 0.0054-0.0447 f/cc, respectively. The fiber concentrations of 35 out of 38 samples(92%) were over 0.01 f/cc which is the Environment Administration's recommended asbestos level for the underground space. This study suggests that most of building insulation materials used in Korea, contain MMMF and sometimes asbestos. Currently, MMMF pollution levels may exceed the Environment Administration's recommended level for underground space. It has been found that airborne fiber concentrations increased significantly with MMMF content and with the maintenance condition of surface material. Therefore, it is recommended that a proper management technique should be developed and immediately implemented since the conditions of surface material will be gradually deteriorated due to building age and usage. Since health hazards of the MMMF, similar to those of asbestos, are being gradually acknowledged, a proper management technique which is applicable to control total airborne fiber concentrations, both asbestos and MMMF, be developed and an acceptable indoor air standard be promulgated as early as possible.

  • PDF