• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.027 seconds

Development of a jet air supplying welding mask for controlling welding fumes (압축공기를 이용한 용접흄 제어용 용접면(JASM)의 개발)

  • Song, Se-Wook;Kim, Jong-Gil;Ha, Hyun-Chul;Kim, Tae-Hyeung;Kim, Jong-Chul;Jung, Yu-Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.98-108
    • /
    • 2000
  • Controlling the over-exposure of welding fumes is not an easy problem because neither general nor local exhaust ventilation systems could be successfully applied. A jet air supplying welding mask was development to reduce the exposure level of welding fumes. The jet airs tream pushes the welding fumes away from the breathing zone by using the frictional characteristic of jet. Laboratory experiments were conducted to optimize the efficiency of controlling welding fumes. Thereafter, its performance was tested in a laboratory and an industrial field. The efficiencies of reducing the welding fume exposure were about 90% and 80% in a laboratory and an industrial field, respectively. Additionally, it resulted in elimination of heat inside the mask and enhancement of clear visuality.

  • PDF

Numerical Study on Ventilation Method for Temperature Control of HRSG Building (HRSG건물 온도제어를 위한 환기방안에 관한 수치적 연구)

  • Kim, Chul Hwan;Lee, Jong Wook;Choi, Hoon Ki;Yoo, Geun Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.240-249
    • /
    • 2009
  • HRSG(Heat Recovery Steam Generator) building is large enclosed structure included various heat sources. This building needs to appropriately keep internal air temperature for worker's safety and operability of control devices. In this study, ventilation analysis is performed to find proper ventilation method for temperature control. Ventilation analysis is applied to entire internal space of the building with standard $k-{\varepsilon}$ model and enhanced wall treatment because of large size of the structure. And the ventilation method is considered natural and forced convection with two louver structures which has damper or not. Louver structure affect directly air circulation in near HRSG and lower region of the building. Forced ventilation provides strong inertial force which cause upward airflow. From the analysis, it is found that design requirement for internal air temperature can be satisfied by forced ventilation method with louver structure without damper.

Study on Accuracy and Validity Tests for Various Prediction Models for Gas and Vapor Respirator Cartridge Service Lives (가스 및 유기용제용 호흡보호구의 정화통에 대한 수명예측방법의 정확도 및 타당성 검증연구)

  • Park, Doo Yong;Park, Ji Young;Yoon, Chung Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.19-31
    • /
    • 1999
  • Most breakthrough tests are conducted at higher concentration levels compared to those in the field of air-purifying respirator applications. For example, typical challenge concentrations for breakthrough tests agains tcarbon tetrachloride are ranged between 250-1000 ppm although applicable concentrations range for air-purifying cartridge is 5-50 ppm for carbon tetrachloride. However, no guarantee has been made that isotherms derived from the experiment at high challenge concentrations could estimate adsorption capacity at the lower concentration range where workers wear usually air-purifying respirators. Three models of adsorption isotherms (Freundlich, Langmuir and Dubinin/Radushkevich(D/R) isotherms) that have been commonly applied for respirator cartridge testing were evaluated. Adsorption capacity at each challenge concentration was calculated from the Reaction Kinetic equation fitted for the breakthrough data. These data were used for derivation of three isotherms. In general, the D/R isotherm has given the best agreement between estimated adsorption capacities and experimentally measured. If the challenge concentration of 100 ppm is included for derivation of models, Freundlich and D/R models could succes sfully produced good estimations for adsorption capacities at 50 ppm level. Estimated adsorption capacities by both models ranged in 94 - 109 % of the experimentally measured. However, Langmuir model gives underes timation in all cases.

  • PDF

A Study on Stroage of Chicken Eggs from Poultry Farms (식란의 보전성에 관한 연구)

  • 조태행;인영민;정갑수;남궁선
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.1
    • /
    • pp.29-36
    • /
    • 1989
  • In order to investigate the Storage time of chicken eggs, several physico-chemical tests from chicken eggs store at 5, 13 and 27$^{\circ}C$ were examined. Egg samples were collected from six poultry farms. Egg stored at 5$^{\circ}C$ based on the depth of air cell and specific gravity, were all acceptable until 17 days ; on the egg yolk coefficient and pH of the egg white and egg yolk until about 10 days. Egg stored at 13$^{\circ}C$, based on the depth of air cell. were acceptable by about 10 days of storage, but on the other physico-chemical tests by about 7 days. Egg samples stored at room temperature(about 27$^{\circ}C$) base on the depth of air cell, were acceptable by about 5 days of storage ; on the specific gravity by 4 days ; and on the egg yolk coefficient and pH of the egg yolk and egg white by 3 days. The results of this study showed that egg stored at 5$^{\circ}C$ were considered acceptable by 10 days of storage ; at 13$^{\circ}C$ by 7 days ; at room temperature (27$^{\circ}C$) by 3 days.

  • PDF

Comparison with decompression time and modes of air decompression tables in 5 countries (5개국 공기잠수감압표의 감압시간과 감압방법 비교)

  • Kang, Joonhyuk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.4
    • /
    • pp.445-453
    • /
    • 2016
  • Objectives: The objective of this study is to assess relative safety level of the decompression tables in Ministry of Employment and Labor Public Notice No. 2014-28 in comparison with overseas decompression tables. Methods: Decompression tables in the Public Notice No. 2014-28 were compared with examples from Japan, the USA, Canada, and France in terms of ascent rate, surface intervals after exceptional exposures, oxygen decompression and allowable partial pressure, depth limits in air diving, no-decompression limits, and decompression time and methods. Results: Public Notice No. 2014-28 does not include air diving depth limits, exceptional exposure limits, mandatory surface intervals after exceptional exposures, oxygen decompression, and surface decompression schedules. Its decompression time was found to be the shortest among the five decompression tables. Conclusions: Public Notice No. 2014-28 has the lowest safety level in comparison with overseas decompression tables. Deck decompression chambers are not applicable due to no regulations on surface interval and oxygen use in the chamber for decompression.

Comparative study of clearing methods for air-borne asbestos analysis (공기 중 석면표준시료를 이용한 전처리 방법 비교 연구)

  • Yi, Gwang Yong;Shin, Jeong Ah;Jeong, Jee Yeon;Lee, In Seop;Park, Doo Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.2
    • /
    • pp.99-102
    • /
    • 2011
  • Objectives: Acetone/triacetine method for clearing cellulose ester membrane (CEM) filter has been a popular method for air-borne asbestos analysis. However, as a weakness of this method, it is time consuming to analyses asbestos samples after sampling. Crystalclear method can be used to analyses asbestos samples promptly after sampling. Although a strength of crystal clear method exists, there was little valid studied for the method. This study was conducted to compare acetone/triacetine method with crystalclear one for analysing asbestos sample. Methods: Test samples made in three different concentration ranges(low, medium and high concentration) were analysed by phase contrast microscopy after acetone/triacetine and crystalclear method treatment respectively. Results: We did not find statistical difference in analysed results between two methods, which were conducted in three different concentrations ranges. Conclusions: We concluded that crystalclear method can be used as clearing method for air-borne asbestos analysis instead of acetone/triacetine method.

Airborne Chlorpyrifos Concentrations and RBC Cholinesterase Activity of Workers in Its Formulation Workplace (클로르피리포스 제조업장의 기중 농도와 작업자의 적혈구 콜린에스테라제 활성도)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.91-99
    • /
    • 2012
  • Airborne chlorpyrifos concentrations in formulation workplaces have not been determined in Korea. The aim of the study was to evaluate chlorpyrifos concentrations of air in a formulation workplace and recognize the RBC cholinesterase activities for the formulation workers. 30 air samples (personal or area sampling) were collected and bood samples from 10 workers were collected for RBC chlorinesterase (RBC AChE) activity in a factory on May 2008. Air samples were collected by the National Institute for Occupational Safety and Health (NIOSH) method and were analyzed by GC-MS. Airborne chlorpyrifos concentrations ranged from 0.003 to $12.90mg/m^3$ and geometric mean (GM) was $0.15\;mg/m^3.$ Compared to Korean Occupational Exposure Limit (KOEL) of 0.1 (2011) or $0.2\;mg/m^3$ (2008), at 95% confidence, airborne concentrations exceeded the KOEL 69.7% or 56.1% of the time or less, indicating that this concentration level was unacceptable according to exposure assessment using a LogNorm2$^{(R)}$. Since the workers were continually at work on the organophosphate or carbamate pesticides formulation, individual baseline for RBC AChE activity was not determined. As the results of comparison with reference average value of RBC AChE activity, it was found that a worker was below 70% RBC AChE activity and five workers were abnormal.

Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma (저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과)

  • Paik, Namwon;Heo, Sungmin;Lee, Ilyoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

Sampling and Analytical Method for Linear Carbonates using GC/FID (GC/FID를 이용한 사슬형 카보네이트 3종의 측정·분석방법)

  • Miyeon Jang;Gwangyong Yi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.455-463
    • /
    • 2023
  • Objectives: The aim of this study was to develop an air sampling and analytical method for estimating worker exposure to linear carbonate solvents and to evaluate the method. Methods: The target substances were three linear carbonates: DMC, DEC, EMC. GC/FID was used for sample analysis. Laboratory experiments were conducted to determine desorption solvents and sample capacity, and to evaluate storage stability, accuracy, and precision. Results: Coconut Shell Charcoal (CSC, 100/50 mg) was used as the air sampling media, and a desorption solvent of 5% methanol/95% dichloromethane was selected. Recommended sampling capacities were 1~11 ℓ for DMC, 1~18 ℓ for DEC, and 1~24 ℓ for EMC. The stability of three linear carbonates was demonstrated over 30 days in a refrigerator (4℃). Detection limits were determined as follows: DMC 0.26 ㎍/sample, DEC 0.24 ㎍/sample, and EMC 0.25 ㎍/sample. The total coefficient of variation was calculated as DMC 0.064, DEC 0.079, and EMC 0.07. Conclusions: This sampling and analysis method is suitable for estimating personal exposure to linear carbonates in the workplace.

Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers (약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례)

  • Je-Hun Kim;Ki-Youn Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.