• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.025 seconds

Prediction of Airflow and Temperature Field in a Room With Convective Heat Source (열원이 존재하는 작업장내 기류 및 온도장 예측)

  • Jung, Yu-Jin;Ha, Hyun-Chul;Kim, Tae-Hyeung;Yoo, Guen-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.78-84
    • /
    • 2001
  • A CFD simulation of airflow and temperature field in a heated room has been described in this paper. The thermal wall jet created by a radiator greatly influences the airflow pattern, temperature distribution. The area close La a heat source has a higher risk of air-borne contamination and imposes a harmful effect on occupants in that area. The predicted flow field, temperature results show good agreement with the measured data. As the results were compared with experimental data, the applicability of CFD was satisfactorily verified. Also, the CFD simulation can capture the natural convective flow features. If a CFD simulation is applied ventilation design with a heat source, An effective design will be attained. Further study is required to improve the accuracy of CFD simulation.

  • PDF

Respirable Cool Dust Exposure Concentration at Work Sites of Underground Coal Mines in Taebaek Area (태백지역 석탄광산의 작업부서별 호흡성 분진 폭로농도)

  • Yoon, Young No;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 1991
  • Exposure level of respirable coal dust of underground coal mines in Taebaek area was evaluated. Personal air samplers with 10-mm nylone cyclones were attached to the coal workers including drillers, coal cutters, their assistants, haulers, and separators. Log-normality of respirable dust exposure concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of respirable dust exposure concentration between work sites were tested by one-way ANOVA test and multiple comparison(Scheffe) test. And differences of respirable dust exposure concentration of principal and assistant workers in drilling sites and in coal faces were tested by paired t-test. Relation of respirable dust exposure concentration for the principal workers and their assistants in drilling sites and in coal faces were tested by regression analysis. The results were as follows : 1. All of the respirable dust concentration were log-normally distributed. 2. There were not only significantly different means of exposure concentration between drillers and coal cutters but between coal cutters and haulers. 3. Means of exposure concentration of drillers and drilling assistants were not significantly different. And means of exposure concentration of coal cutters and coal cutting assistants were not different.

  • PDF

Occurrence types and mineralogical characteristics of asbestos for the Kwangcheon area, Chungnam (충남 광천지역 석면의 산출 유형 및 광물학적 특징)

  • Song, Suckhwan;Hwang, Jung Hwan;Hwang, Byum Goo;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.4
    • /
    • pp.271-281
    • /
    • 2008
  • This study is to characterize the occurrence types and mineralogical characteristics of asbestos for the Kwangcheon areas, Chungnam. The mine areas had been exploited as asbestos mines for several decades since 1930. Host rocks of the asbestos are serpentinites and altered rocks of the ultramafic rocks. Representative samples of the host rocks and minerals were sampled and were examined with microscopes. To confirm for the existences and compositions for the asbestos, the rock samples were analysed with EPMA, XRD and EDS. Chrysotile, tremolite and actinolite were found as asbestos and non-asbestos forms in these areas. Chrysotiles, as non-asbestos forms, occur in the host rocks with mesh and hourglass textures. They, as asbestos forms, are mainly found as the veins. The tremolite and actinolite, as asbestos types, occur as alteration products of the olivine and pyroxene within the host rocks. They, as asbestos types, are also found following the cracks and fractures. Overall results suggest that three types of the asbestos are found in the Kwangcheon and Kaewol mine areas. Based on the occurrence types for the asbestos, additional studies are required for the asbestos in the top soil and air.

Analysis of Benzo(a)pyrene in Red Ginseng Beverage (홍삼음료 증 벤조피렌 분석)

  • Hu, Soo-Jung;Jin, Sun-Hee;Choi, Dong-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2008
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several source including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water or soil. A red ginseng is produced by steaming the root followed by drying. The methodology involved extraction with n-hexane and washing with water, clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD. The mobile phase was a mixture of acetonitrile and water in 8:2 by the isocratic elution and the excitation wavelength of fluorescence detector was 294 nm and its emission wavelength was 404 nm. The average recovery was about 105% and the relative standard deviation was 0.5. The levels of benzopyrene in the selected red ginseng beverage samples were not detected.

Numerical Study on the Ventilation Performance in the Boiler Building with and without Roof Openings (루프 환기구에 따른 보일러빌딩 내부 환기성능에 관한 수치적 연구)

  • Choi, Hoon Ki;Yoo, Geun Jong;Lee, Sang Heon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.342-349
    • /
    • 2016
  • Objectives: The objective of this paper is to find flow and heat transfer characteristics numerically in boiler buildings for three different ventilation window configurations. Methods: Turbulent natural convection flow in boiler buildings with a constant heating wall temperature was analyzed numerically. Governing equations were solved with standard finite-volume method using the SIMPLE algorithm. Conclusions: Flow and heat transfer characteristics are found for three different ventilation types. In the lower area under furnace, velocity and temperature distributions show similar patterns among the three different ventilation types. In the upper area over furnace, however, air flow is well mixed with lower peak temperatures for types B and C, which have roof ventilation windows, compared to type A which has side wall louvers only. Also, type B, with a single large roof window, shows better ventilation effect than does type C with its distribution roof windows.

Diethylnitrosamine Induced Tissue Damage and Change of Lipid Components in the Chick Embryo Liver (Diethylnitrosamine에 의한 계배 간 조직 손상 및 지질 성분의 변화)

  • 박정현;강성조;강진순;정덕화
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.1
    • /
    • pp.60-66
    • /
    • 1999
  • Diethylnitrosamine (DEN) is known as a potential hepatic carcinogen by single administration. This study was designed to measure the effects of DEN-induced cell damage on the triglyceride and cholesterol concentration in the liver, excluding dietary effects. Fertilized chicken eggs, 10 days before hatching, were randomly divided into three groups (n=20) and each egg was injected 10 ${mu}ell$ of corn oil (vehicle control), 5 $\mu\textrm{g}$ of DEN/10 ${mu}ell$ of DEN/10 ${mu}ell$ into yolk via air sac. After 48 hr and 96 hr incubation, the damage of the chick-embryo liver cell was investigated by electron microscopy and by measuring the concentration of lipid components (total cholesterol, free cholesterol, phospholipid and triglyceride). For eggs administered 10 $\mu\textrm{g}$ of DEN and incuvated 96 hr, in hepatocyte, the nucleus membrane was roughed, the size of nucleolus was apparently increased and euchromatin was accumulated. Mitochondria were condensed and cristae, located mitochondiral inner membrane, were obscured. Additionally, the leaves of triglyceride and cholesterol classes were significantly increased depend on the amount treated with 10 $\mu\textrm{g}$ DEN at 96 hr, but phospholipids component of cell membrane, were decreased with significance. As a conclusion, carcinogen induced hepatic lesion was correlated with the changes in lipid component of liver.

  • PDF

Quantitative and qualitative analysis of microorganisms in dental unit water (치과용수 미생물의 정량적 및 정성적 분석)

  • Lee, Seung-Hee;Park, Ji-Hye;Sakong, Joon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.4
    • /
    • pp.433-440
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the pathogenicity of microorganisms by quantitative and qualitative analysis of microorganisms before and after flushing of dental unit water. Methods: This study was conducted on the supply of high-speed handpieces, ultrasonic scalers, and air-water syringes, which sterilized from 10 dental unit chairs at a dental clinic in South Gyeongsang Province. The number of bacterial communities was calculated by collection before and after flushing (2, 4, and 6 minutes). Results: The mean number of bacteria in the handpiece water before flushing was $27,208CFU/m{\ell}$; 2 minutes after flushing, $2,180CFU/m{\ell}$; 4 minutes after flushing, $900CFU/m{\ell}$; and 6 minutes after flushing, $412CFU/m{\ell}$. Conclusions: To minimize the risk of cross-infection and intra-clinic infection in dental clinics, education and water quality monitoring may be needed.

Chromosome Aberrations of Styrene Exposed Workers (스티렌 취급근로자의 염색체이상연구)

  • Maeng, Seung Hee;Kang, Sung Kyu;Yang, Jung Sun;Lee, Jong Sung;Yu, Il Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.40-47
    • /
    • 1995
  • We analyzed sytrene concentrations in air and in blood, mandelic acid in urine, and chromosome aberrations in peripheral lymphocytes of twenty one styrene-exposed workers in two reinforced plastic factories. In addition, in vitro testing for chromosome aberration was carried out. The dose-dependent clastogenicity of styrene was confirmed in the cultured Chinese hamster lung cell(CHL) with metabolic activation. The environmental styrene concentrations and urinary mandelic acid levels of analyzed subjects were different in two plants examined, but the exposure levels in most workers examined were lower than the permissible exposure levels. Chromosome aberrations of the styrene exposed workers showed no increase in the percentage of aberrant cells as compared with the control group. No correlation was found between the exposure levels and the frequencies of chromosome aberrations in workers.

  • PDF

Assessing Hematological Change Associated with Cardiovascular Disease Risk among Korean Taxi Drivers Using Data from the Second (2012-2014) Korean National Environmental Health Survey: A Propensity Score Matching Approach (제2기(2012-2014) 국민환경보건 기초조사 자료를 활용한 국내 남성 택시 기사의 심혈관계 위험도 관련 혈액학적 변화에 대한 연구: 성향점수 매칭을 활용하여)

  • Baek, Kiook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.367-377
    • /
    • 2021
  • Objectives: Taxi drivers are exposed to various hazards, such as long periods of sedentary work and traffic-related air pollutants. However, studies on the health effects among taxi drivers in South Korea are insufficient. Methods: To assess subclinical hematologic change related to cardiovascular disease among male taxi drivers, we analyzed data from the second Korean National Environmental Health Survey. Fifty-nine taxi drivers and 1,912 controls were included in the analysis. Propensity score matching was performed to adjust for age, body mass index, and urinary cotinine. A total of 295 subjects were matched with 59 taxi drivers. Leukocyte count, platelet count, hematocrit, triglyceride, total cholesterol, HDL cholesterol land total IgE of the taxi drivers were compared with the control groups. Results: Taxi drivers showed significantly elevated blood leukocytes and platelets. Serum total IgE was significantly reduced in taxi drivers. However, blood leukocytes, platelets, and serum total IgE were not significantly correlated with work period among taxi drivers. Conclusions: Regarding the change of the blood leukocyte count, platelet count, and serum total IgE, taxi driving has the possibility to be associated with peripheral inflammation, humoral immunity and cardiovascular risk.

Exposure Assessment of Cashiers at Expressway Tollbooths (고속도로 톨게이트 요금수납원의 작업환경 유해인자 노출평가)

  • Park, Hae Dong;Kang, Joon Hyuk;Kim, Joonbeom
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.1
    • /
    • pp.13-21
    • /
    • 2021
  • Objectives: The purpose of this study was to evaluate the exposures of cashiers who work at expressway tollbooths. Methods: We measured temperature(temp.), relative humidity(RH), and contaminants with direct reading instruments at ten expressway toll gate in September 2015. Elemental carbon was collected on the quartz filters and analyzed with an OCEC analyzer. Results: The average levels for temp., RH, carbon monoxide, carbon dioxide, dust(PM10), and black carbon were respectively 24.6~27.8℃, 32.3~65.3%, 0.5~1.2 ppm, 456~559 ppm, 12~111 ㎍/㎥, and 3.1~10.1 ㎍/㎥ at each tollbooth. The concentrations of elemental carbon within the tollbooth(1.8~7.2 ㎍/㎥) were lower than outdoors(2.5~10.0 ㎍/㎥), but exhibited a high correlation(r2=0.855). The exposure levels for carbon monoxide, black carbon, and elemental carbon in the tollbooths were significantly higher than the offices. The concentrations of black carbon and elemental carbon showed a high correlation(r2=0.756). Conclusions: The levels of contaminants were below the occupational exposure limits in the expressway tollbooth. There were ventilation and air conditioning systems in the booths, but it is necessary to maintain and use the systems properly.