• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.031 seconds

A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites (환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구)

  • Lee, Jeong Joo;Lee, Ju Sang;Kim, Shin Do
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

Assessment of indoor ventilation in commercial office buildings (업무용 빌딩 소재 사무실의 실내환기 평가)

  • Jeong, Jee Yeon;Lee, Gwang Yong;Lee, Byung Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • In winter season, the survey was performed in three commercial office buildings in the metropolitan Seoul, Pusan, and Gwangju city. The purpose of the survey was to evaluate the effectiveness of ventilation for offices in commercial buildings. The data were compared to standard of applicable to the indoor ventilation in office. The results indicated that the most commercial office buildings used the air handing unit and fan coil unit as HVAC system, and the intake amount of fresh outdoor air were very inadequate to compared to the ASHRAE standard value of $0.57\;m^3/min/person$. Also the surveyed all commercial office building used the HVAC system as a meas of controlling temperature for office indoor air. Ultimately, these results presented that there were possibility of evoking indoor air quality problems by the insufficient ventilation.

Sampling and Analysis of Parathion in the Air and Urinary p-Nitrophenol for Parathion Manufacturing Workers (작업장 공기 중 파라티온과 작업자 소변 중 p-니트로페놀의 시료채취 및 분석)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.300-309
    • /
    • 2007
  • Although parathion is an organophosphate pesticide being legally applied for the purpose of agriculture and is being manufactured, parathion in the air and urinary p-nitrophenol, a metabolite of parathion, were not analysed in Korea. Air of the parathion manufacturing workplace was sampled by OVS-2 tubes using NIOSH 5600 and spot urine of workers was sampled at the end of shift. Parathion and urinary p-nitrophenol were analysed by GC/MS (5973 MSD connected with Agilent 6890 GC) and the protocol was included in this study. It was found that this protocol should be so sensitive that determining parathion in the air and urinary p-nitrophenol below level of ACGIH TLV and BEI be adequate. Another finding was that total sampling volume of air of NIOSH 5600 of 240 L should be adjusted to be less than 120 L due to breakthrough.

Pollution investigation of ventilated system in super market and hotel's air condition in Kunming city

  • Zhang, Liang;Wang, Xin;Liu, Xinhai
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.12a
    • /
    • pp.12-14
    • /
    • 2004
  • Objective to know about pollution of ventilated system in super market and hotel's air condition in Kunming. Methods to take out 28 ventilated system from super markets and hotels in Kunming in march 2004. To check dirt amount in pipelines and microorganism in dirt. Testing result is appraised under 'Public hygiene standard of ventilated system in air condition'. Results pollution problem exist in different degree in all the super markets and hotels that have been investigated. There is 32.14% which means 8 hotels and 1 super market, pollution is serious, The others (67.86%) is medium. Conclusion pollution problems exist in air condition system in all super markets and hotels of Kunming. Discussion aim at Kunming's special weather, and present condition of public ventilated system, discussing ways of management in hygiene of air condition system.

  • PDF

Development of a Low Noisy Type of Air-line Mask (저소음형 송기마스크 개발)

  • Paik, Eun-Gyu;Kim, Bong-Nyun;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

Comparison of Antimicrobial Effect of Alcohol Gel according to the Amount and Drying Time in Health Personnel Hand Hygiene (의료종사자 손 소독용 알코올 젤의 사용량과 건조시간에 따른 항균효과의 비교)

  • Ji, Yoon Jung;Jeong, Jae Sim
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the effect of alcohol gel according to the amount and drying time in health personnel hand hygiene and to promote in their practice adequate and effective hand hygiene. Methods: The crossover experimental study was performed with 14 volunteers. Hands were artificially contaminated with 5 mL of $10^8$ CFU/mL of Serratia marcescens (ATCC 14756) and four different alcohol gel hand hygiene methods varying by the amount of alcohol gel (2 mL vs. 1 mL) and drying time (complete vs. incomplete) were compared. Samples were collected by glove juice sampling procedures. Results: Mean log reduction values of the four different hand hygiene methods were $2.22{\pm}0.36$, $1.26{\pm}0.53$, $1.49{\pm}0.60$, $0.89{\pm}0.47$ respectively for the 4 groups: adequate amount (2mL) and complete dry (30 seconds rubbing followed by 2 min air-dry), inadequate amount (1 mL) and complete dry, adequate amount and incomplete dry (15 seconds rubbing and no air-dry), and inadequate amount and incomplete dry. The difference was statistically significant in the adequate amount and complete dry group compared to other three groups (p<.001). Conclusion: Only alcohol gel hand hygiene with adequate amount and complete drying was satisfactory by U.S. FDA-TFM efficacy requirements for antiseptic hand hygiene products.

A Study for the Indoor Air Concentration of VOCs and HCHO in Newly Built and Remodeled Classrooms (신개축 교사내 실내공기중 휘발성유기화합물과 폼알데히드의 농도 특성)

  • Park, Jeong Ho;Yang, Su Myoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.222-228
    • /
    • 2013
  • Objectives: The indoor air quality of newly-built (NC) and remodeled (RC) school classrooms was assessed. The primary aim was to show correlations between volatile organic compounds (VOCs) and formaldehyde (HCHO) pollutant levels. Methods: This study investigated the indoor air concentrations of VOCs and HCHO at 26 sites of newly built and 68 sites of remodeled classrooms located in South Gyeongsang Province between 2010 and 2012. VOCs in the indoor air were determined by adsorbent tube (Tenax TA) and automatic thermal desorption coupled with GC-MS analysis. Target analytes were five VOCs: benzene, toluene, ethylbenzene, xylene, and styrene. HCHO was collected with a 2,4-DNPH cartridge and analyzed by HPLC. Conclusions: This study estimated that indoor VOCs and HCHO concentrations in the classrooms were mainly affected by interior building materials and classroom equipment. For proper indoor air quality in schools, classroom air should be improved through reduction of hazardous materials by adequate ventilation, selecting environmental friendly materials, etc.

Noise Reduction of Reciprocating Type Air Compressors (왕복동식 공기압축기의 소음저감에 관한 공학적 대책 연구)

  • Lee, Kwang-Gil;Park, Jae-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.12-16
    • /
    • 2006
  • This paper deals with the noise evaluation and noise reduction of a reciprocating air-compressor. The reciprocating air-compressor is widely used in the small and medium sized industrial firms, many employees exposed and irritated by their noise in the workplace. Thus, appropriate noise control actions should be taken to prevent hearing loss due to the its noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known to be motor, belts, suction valves, discharge valves, moving parts, and flow-induced noise caused by edges or discontinuities along the flow path including expansions, contractions, junctions and bends. As a result, the main noise sources of the air-compressor are categorized by the suction and discharge noise, valve noise, and compressed air tank noise. Based on the investigations, mufflers are designed to reduce both the suction and discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, a noise reduction up to 10dB(A) could be achieved for the air-compressor.

The Development of New Diffusive Sampler for Formaldehye in Air (기중 포름알데히드 측정을 위한 확산포집기의 개발)

  • Choe, Mee-heon;Lee, Kwang-Mook;Roh, Young-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.173-186
    • /
    • 1999
  • To utilize diffuse sampling of formaldehyde in air, a new sampler was designed. A glass fiber filter was impegnated with 2,4-dinitrophenylhydrazine(DNP) and phosphoric acid and mounted 37mm cassette. The formaldehyde vapor was sampled in the dynamic chamber and measured by high performance liquid chromatograph and compared with solid sorbent tube. The results were as follows ; 1. The desorption efficiencies of diffusive sampler between 97.0% and 100%. 2. the sampling rate is constant as in $58{\sim}61.8m{\ell}/min$ when sampling times are between 120 and 360 min. 3. There was a significant relationship between concentrations of diffusive samples and active samples with the coefficient of determination(R2) of 0.92. 4. Desorbed amount of formaldehyde diffusive sampler was increased by high relative humidity. 5. Wheth diffusive samplers were stored at room temperature or at refrigerator there was no statistically significant difference in the accuracy of result. 6. When the diffusive samplers, which collected formaldehyde vapor, were exposed to clean air for three hours, there was no significant loss of formaldehyde due to reverse diffusion. In conclusion, this study suggest that developed diffusive samplers will be a reasonable substitute for the solid sorbent tube for sampling formaldehyde and practical comparative study of developed diffusive sampler should be performed at workplaces of manufacturing industry.

  • PDF

Influence Factors on Health of Dental Hygienist by Dental Office's Indoor Air Quality (치과위생사의 병원실내공기질에 의한 건강영향요인)

  • Park, Myung-Suk;Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • This survey was compared and analyzed about the primary factor that dental office's working environment effect on physical subjective symptom and based on self-filling survey, 656 dental hygienists on July through August 2006, and analyzed using descriptive statics, ANOVA and Multiple Regression Analysis. The result of satisfaction degree of hospital working environment was pretty low about office air condition. Most people have complained that office's air quality makes it difficult to their work and mentioned that they were sore and dull all over the back, shoulder, and neck. The odor is major factor to be satisfied with office environment. Proper ventilates the way open the window more often was essential to maintain fresh indoor air quality and keep the extraction materials by separator and sealing tightly for remove the odor. Other factors were temperature, lighting fixture, ventilation facilities, and freshness of air. Dental hygienist was unsatisfied with hospital air condition and this polluted air condition was the cause of physical subjective symptom in work place. Furthermore, this research would be applied for improvement of working environment by decreasing of indoor air pollution.

  • PDF