Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos (공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교)

  • Jang, Bong-Ki;Tak, Hyun-Wook;Song, Su-Jin;Jo, Bong-Hyun;Kim, Yeong-Ji;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

A Study on the Distribution of VOC Concentrations by Attachment Position of Air Samplers for Working Environment Measurement (작업환경측정 시료 채취기의 부착 위치에 따른 유기화합물의 농도 분포에 관한 연구)

  • Kwon, Yung-Gyu;Won, Jung Il;Jang, Hyung Seok;Sim, Sang-hyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.328-337
    • /
    • 2015
  • Objectives: The purpose of this study is to investigate differences in concentration according to the position at the left or right shoulder within a 30 cm of radius of workers' respirators and provide basic data for the establishment of an industrial health policy. Methods: Personal samples were collected from a total of 65 workers from 27 manufacturing firms in South Gyeongsang-do Province from November 5, 2011 to December 30, 2012 after classifying the laborers into left- and right-side groups. The organic compound samples were collected and analyzed in accordance with the NIOSH Manual of Analytical Methods (NMAM) 1501. Results: In terms of the concentration of organic compounds collected from both left and right shoulders at the position of workers' respirators, isobutyl acetate was the highest with 145 ppm at the left shoulder, followed by ethyl acetate (133.5 ppm) and toluene (38.13 ppm). At the right shoulder, on the contrary, ethyl acetate (149.3 ppm) was the highest, followed by toluene (46.26 ppm), xylene (29.63ppm) and isopropyl alcohol (28.06 ppm). Overall, the right shoulder was higher than the left shoulder in terms of concentrations. Conclusions: For the measurement of the working environment, workers' personal samples should be collected at the place closest to the respirator. In terms of the reduction of error, the attachment of two sample media is expected to reduce errors in exposure assessment.

A study on the state of infection control in dental clinic (치과진료실에서의 감염관리 실태 조사)

  • Kim, Kyung-Mi;Jung, Jae-Yeon;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.3
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

The change of air lead concentrations in litharge making and smelting industries (일부 제련 및 리사지 사업장에서 공기중 납 노출농도의 변화)

  • Choi, Jae-Wook;Kim, Nam-Soo;Cho, Kwang-Sung;Ham, Jung-O;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • To provide necessary information for future environmental monitoring of smelting and litharge making industries in Korea, environmental monitoring dataset of air lead concentration of 4 lead industries(1 primary smelting, 2 secondary smelting and 1 litharge making industry) were analyzed from 1994 to 2007. Data were compared using geometric mean and standard deviation with minimum and maximum values according to year of measurement, type of lead industries and type of operation of lead industries. The geometric mean and standard deviation of air concentration for a total of 1140 samples in all lead industries for overall 14 years were 70.7${\mu}g/m^3$ and 5.51 with minimum of 1${\mu}g/m^3$ and maximum of 9,185 ${\mu}g/m^3$. The overall geometric means of air concentration were above the permissible exposure levels(PEL) until year of 2001 and thereafter they were remained at the level of half of PEL. The geometric means of primary smelting, secondary smelting and litharge making industry for overall 14 years were 21.7${\mu}g/m^3$(number of samples: 353), 82.5${\mu}g/m^3$(number of samples: 357) and 164.2 ${\mu}g/m^3$(number of samples: 430) respectively. In primary smelting industry, the highest geometric mean air concentration was 35.4 ${\mu}g/m^3$ in the secondary smelting operation; followed by casting operation (24.9 ${\mu}g/m^3$) and melting operation (14.9 ${\mu}g/m^3$), respectively. On the other hand, in secondary smelting industries, the highest geometric mean air concentration was 125.4${\mu}g/m^3$ in melting operation; followed by casting operation (90.5${\mu}g/m^3$) and pre-treatment operation (43.4${\mu}g/m^3$), respectively. However, in litharge making industries, there were no significant differences of geometric mean air concentrations between litharge operation and stabilizer operation. The proportion of over PEL (50${\mu}g/m^3$) was highest in litharge industry and followed by secondary smelting industries. However The proportions of over PEL(${\mu}g./m^3.$) were decreased by the years of environmental monitoring. The significant reduction of mean air lead concentration since year of 2000 was observed due to more active environmental engineering control and new introduction of new operation in manufacturing process, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist according to more strict enforcement of occupational and safety law by the government.

Evaluation of Mixed Organic Solvent Exposures in Painting Plants (도료 제조업 근로자들의 복합유기용제 폭로농도에 관한 연구)

  • Choi, Ho Chun;Oh, Doe-Suk;Oh, Se-Min;Chung, Kyou-Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.177-187
    • /
    • 1993
  • The exposure levels of mixed organic solvents for 66 exposed workers in six paint manufacturing plants were evaluated. In 66 exposed workers and 30 control subjects, we also determined the concentrations of toluene and xylene metabolites, hippuric acid, ($o^-$, $m^-$, and $p^-$)methylhippuric acid. The results were as follow ; 1. Seven organic compounds, which on averge accounted for approximately 90% of the identified mass in each painting plants air samples, were selected for quantification : methyl ethyl ketone, ethyl acetate, methyl isobutyl ketone, toluene, butyl acetate, ethyl benzene, ($o^-$, $m^-$, $p^-$)xylene. 2. The average mixed organic solvent exposure levels in 66 points with workplce were 3.8ppm of MEK, 12.2ppm of ethyl acetate, 4.0ppm of MIBK, 28.7ppm of toluene, 3.8ppm of butyl acetate, 10.2ppm of ethyl benzene, 14.6ppm of xylene, respectively. 3. For the total 66 points with workplace, the rate of them of which mixed solvents in air was exceeded th TLV of 1.0 were obtained for 23%(15/66 point). 4. The concentrations of hippuric acid in urine of exposed group and control were $0.94{\pm}0.65g/g$ of creatinine, $0.16{\pm}0.11g/g$ of creatinine, respectively. 5. There was a linear correlation between the end shift hippuric acid acid levels in urine and exposed toluene in air : y=0.02079X+494.2, r=0.6488, n=55 y:hippuric acid in urine(mg/g of creatinine), x:toluene levels in air(ppb) Toluene levels of 100ppm in air have been caculated to hippuric acid of 2.57g/g of creatinine in urine. 6. There was a linear correlation between the end shift methylhippuric acid acid levels in urine and exposed xylene in air : y=0.01664X+31.6, r=0.7264, n=55 y:methylhippuric acid in urine(mg/g of crea.), x:xylene levels in air(ppb) Xylene levels of 100ppm in air have been caculated to methylhippuric acid of 1.69g/g of creatinine in urine.

  • PDF

The Effectiveness of Air Insoles in Improving Temporomandibular Disorders

  • Mi-Ae Sung;Su-Youn Ko;Dong-Kyu Kim
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.273-280
    • /
    • 2023
  • Objective: In patients with temporomandibular joint disorders, air insoles are used to investigate functionality and pain changes in the temporomandibular joint when walking in daily life. Intervention: Sixty-five patients with temporomandibular joint disorder were recruited: 34 as a control group who walked more than 7,000 steps a day in daily life, and 31 as an experimental group who were instructed to take at least 7,000 steps every day while wearing their air insoles. Measurements: To determine the effects of air insoles on temporomandibular joint pain, steady-state pain, maximum mouth opening, average pain, and the most severe pain were measured before and after the experiment. In addition, to evaluate functionality, the ability to open the mouth in a comfortable state, pain when opening the mouth, and the point of sound and maximum degree to which the mouth could be opened were evaluated before and after the experiment. Results: Pain, mouth openness, and sound points showed significant differences from the control group after the experiment, and the maximum mouth opening range showed no significant difference. Conclusion: When air insoles were used by patients with temporomandibular joint disorder, the functionality of the temporomandibular joint was improved and pain was decreased.

Current Situation and Improvement of Indoor Air Quality at University Dormitory (대학교 기숙사의 실내공기환경 실태 및 개선방안)

  • Choi, Lyoung-Hee;Kwon, Oh-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.251-256
    • /
    • 2009
  • The purpose of this study was to suggest the idea for IAQ improvement of university dormitory through space analysis and residents' evaluation. The data was collected from 105 Konkuk university dormitory residents by a questionnaire survey. As a result, the idea for IAQ improvement of university dormitory can be suggested. First, it was found that it was necessary to improve size of windows and to exchange bathroom exhaust system for ventilation. Secondly, it is important for resident to ventilate and clean their room. Thirdly, the educational program for dormitory residents about maintenance of IAQ was esssentially needed. Also, it is necessary to manage air conditioning equipment maintenance and bathroom hygiene.

  • PDF

Effects of Ozone Treatment by Microorganisms Inactivation in the Food Industry (식품산업에서의 미생물 제어를 위한 오존처리 효과)

  • Gwon, O-Jin;Kim, Su-Jin;Byeon, Myeong-U
    • Food Science and Preservation
    • /
    • v.3 no.2
    • /
    • pp.149-154
    • /
    • 1996
  • In order to develovpment of new sterilizing method applied to food industry, effects of ozone treatment on microorganisms, associated with food hygiene were investigated. Microorganisms were immersed in water and sparged with ozonised air(ozone concentration, 3mg liter-1) at an air flow rate of 5 liter min-1. When organisms were treated with benzoic acid and sorbic acid of 0.4∼1.0g/$\ell$, respectively, they were not dectable perfectly. Sodium benzoate had an effect on Penicillium islandicum. When bacteria were sparged with ozonised air, Pseudomonas aeruginosa completely inhibited at 60 minutes, and the killing Aspergillus flavus and Penicillium islandicum. Also, all of bacteria were inactivated after immersed with ozonated water for 10minutes, but two fungal species were not effective.

  • PDF

Experimental Study on the Thermal Insulation of Woman's Korean-Styled Clothes under Still Air Condition -by the Instrumented Copper Mannequin on Standing-posture- (무풍안정시의 부인용한복의 보온력에 관한 연구 -동제인체모형에 의한 실험-)

  • Choi Jeongwha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.1 no.1
    • /
    • pp.7-13
    • /
    • 1977
  • The insulating values of 7 kinds of woman's Korean-styled clothes were examined on the instrumented copper mannequin standing upright under still air condition in a climatic chamber at $20^{\circ}C$ and $60\%$ R.H.. Results obtained are as follows: 1) High correlation coefficients were found in both between total insulating values of clothing (IT) and total clothing weight. and between IT and total clothing thickness while no significant difference was found between total clothing weight and total clothing thickness. 2) It seems possible to predict the approximate insulating value of woman's Korean styled clothes on still air condition by the total clothing weight.

  • PDF

A Study on Composition of Solvent Thinners and Evaporation in the Air (일부 신나의 구성성분과 공기중 증발에 관한 연구)

  • Zoh, Kyung Ehi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.245-263
    • /
    • 1997
  • For twelve solvent thinners, evaporation rates of components were investigated and models to estimate the actual concentration have been evaluated. Also, the current ACGIH TLVs (Threshold Limit Values) for the concentration of organic mixtures have been adjusted. The results of this study are summarized as follows : 1. Airborne concentrations of solvent thinner components were related to their respective vapor pressure (r=0.96). On the other hand, there was no significant relation between the concentrations in the air of the thinner compounds and the original amount in liquid form. 2. Airborne concentrations of each chemical were estimated by temperature at $8.5{\pm}1$, $16.7{\pm}1$ and $31.5{\pm}2^{\circ}C$ with an air velocity of 1.5 m/s. The concentrations were increased by increasing temperature (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl acetate, n-butyl alcohol, m-xylene, p-xylene and o-xylene showed a clear relationship to temperature. 3. Airborne concentration of each chemical was estimated by air velocity at 0.05, 1.50 and 2.50 m/s, with a constant temperature at $17{\pm}2^{\circ}C$. The concentrations were increased by increasing air velocity (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl alcohol, m-xylene and p-xylene showed a clear relationship to velocity. 4. In estimating the concentrations of solvent thinners by temperature and air velocity, ACGIH TLVs for mixtures tended to be larger than the values obtained by ACGIH exposure index. It shows that ACGIH TLVs for mixtures are not adequate for evaluating the airborne concentration of thinners and other organic mixtures. 5. The evaporation rate of the thinners were compared to the theoretical equations of Hummel, Braun and Mackay. The Hummel and Braun methods were close to exposure index but Makay's showed an underestimated value. In order to see the accuracy of each three models, the SSE (Error Sum of Squares) calculated for Hummel's was 1.73, being the closest to the actual values. 6. Present ACGIH TLVs for mixtures are not appropriate evaluate industrial environments. In this study, a correction of TLVs using vapor pressure of respective components was suggested. In order to evaluate the corrected TLVs a paired t-test was performed. There was no significant difference between the exposure index and the concentration over suggested TLVs (p>0.05). Thus, this corrected TLVs seem appropriate in order to evaluate actual industrial workplaces organic chemical concentration in the air.