• Title/Summary/Keyword: Air Flow Analysis

Search Result 2,136, Processing Time 0.029 seconds

Computation of Flowfield and Infrared Signature in Aircraft Exhaust System for IR Reduction Design (항공기 후방동체 열유동장 및 IR 신호 예측 시스템)

  • Moon, Hyuk;Yang, Young-Rok;Chun, Soo-Hwan;Choi, Seong-Man;Myong, Rho-Shin;Cho, Tae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.7
    • /
    • pp.652-659
    • /
    • 2011
  • A computational system to predict flowfield and infrared signature in aircraft exhaust system is developed. As the first step, a virtual mission profile is considered and an engine is selected through a performance analysis. Then a nozzle that meets the requirement of each mission is designed. The internal flow in the exhaustion nozzle at the maximum thrust is analyzed using a state-of-the-art CFD code. In addition, a system to combine information of the skin temperature distribution of the nozzle and after-body surface with an infrared prediction code is developed. Finally, qualitative results for the infrared signature reduction design are obtained by investigating the infrared signature level under various conditions.

Microbiological Hazard Analysis of Cooked Foods Donated to Foodbank (II) (푸드뱅크 기탁 조리식품의 미생물학적 위해분석 (II))

  • Park, Hyeong-Su;Ryu, Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.13 no.4
    • /
    • pp.389-406
    • /
    • 2007
  • This study was conducted to estimate the safety level of non-cooking and cooking processed foods to propose the sanitary management of foods donated to foodbanks. The time and temperature were measured and the microbial levels of aerobic plate counts (APC), coliforms, E. coli, Salmonella spp., S. aureus, B. cereus, and E. coli O157:H7 were analyzed on ten food items donated to seven foodbanks. The amount of cooked foods donated to each foodbank was about 10 to 40 servings. All foodbanks hired a supervisor and had at least one refrigerator/freezer and one temperature-controlled vehicle, but only four foodbanks had the separate offices to manage the foodbank operation. The flow of donated foods was gone through the steps; production, meal service and holding at donator, collection by foodbank, transport (or holding after transport) and distribution to recipients. After production, the levels of APC of both non-cooking and cooking processed foods were complied with the standards by Ministry of Education & Human Resources Development, and were not increased till distribution. Only the level of coliforms in dried squid & cucumber salad (1.5×$10^3$ CFU/g) was not met the standards. E. coli and other pathogens were not detected in all tested samples. The microbial levels of delivery vessels and work tables were satisfactory, but the APC levels of two of four tested serving tables (6.9×$10^3$ and 5.3×$10^3$ CFU/100$cm^2$) and the coliforms level of one (1.1×$10^3$ CFU/100$cm^2$) were over the standards. The air-borne microflora level in serving room was estimated as satisfactory. It took about 3.0 to 6.5 hours from after-production to distribution and the temperatures of donated foods were exposed mostly to temperature danger zone, which had a high potential of microbial growth. These results imply that a checklist to monitor time and temperature in each step should be provided and the employees involving foodbank operation should be properly educated to ensure the safety of donated foods.

  • PDF

An Analysis of Low-level Stability in the Heavy Snowfall Event Observed in the Yeongdong Region (영동지역 대설 사례의 대기 하층 안정도 분석)

  • Lee, Jin-Hwa;Eun, Seung-Hee;Kim, Byung-Gon;Han, Sang-Ok
    • Atmosphere
    • /
    • v.22 no.2
    • /
    • pp.209-219
    • /
    • 2012
  • Extreme heavy snowfall episodes have been investigated in case of accumulated snowfall amount larger than 50 cm during the past ten years, in order to understand the association of low-level stability with heavy snowfall in the Yeongdong region. In general, the selected 4 events have similar synoptic setting such as the Siberian High extended to East Sea along with the Low passing by the southern Korean Peninsula, eventually inducing easterly in the Yeongdong region. Specifically moist-adiabatically neutral layer has been observed during the heavy snowfall period, which was easily identified using vertical profiles of equivalent potential temperature observed at Sokcho, whereas convective unstable layer has been formed over the East sea due to relatively warm sea surface temperature (SST) about $8{\sim}10^{\circ}C$ and lower temperature around 1~2 km above the surface, obtained from RDAPS. Difference of equivalent potential temperature between 850 hPa and surface as well as difference between air and sea temperatures altogether gradually increased before the snowfall period. Instability-induced moisture supply to the atmosphere from the East sea, being cooled and saturated by the upper cold surge, would make low-level ice cloud, and eventually move inland by the easterly flow. Heavy snowfall will be enhanced in association with low-level convergence by surface friction and upslope wind against Taebaek mountains. This study emphasizes the importance of low level stability in the Yeongdong region using the radiosonde sounding and RDAPS data, which should quantitatively be examined through numerical model as well as heat and moisture supply from the ocean.

A novel method for high-frequency transgenic shoot regeneration via Agrobacterium tumefaciens in flax (Linum usitatissimum L.)

  • Beyaz, Ramazan;Darcin, E. Selcen;Aycan, Murat;Kayan, Mustafa;Yildiz, Mustafa
    • Journal of Plant Biotechnology
    • /
    • v.43 no.2
    • /
    • pp.240-247
    • /
    • 2016
  • In this study, routinely used transformation method, which includes transferring explants onto co-cultivation medium after inoculating them with bacterial solution for a while, was compared with 3 different inoculation methods. In every 3 methods, hypocotyl explants excised from 7-day-old sterile flax seedlings having cotyledon leaves and no root system dried under air flow in sterile cabin for 35 min were inoculated with different volumes of bacterial solution at different inoculation periods. GV2260 line of Agrobacterium tumefaciens having 'pBIN 19' plasmid containing npt II (neomycin phosphotransferase II) gene and GUS reporter gene was used in transformation studies. After inoculation, hypocotyl segments of seedlings (0.5 cm in length) - were excised and left to co-cultivation for 2 days. Then, explants were transferred to regeneration medium supplemented with different antibiotics. The presence of npt-II and GUS genes in transformants was confirmed by PCR and GUS analysis. The highest results in all characters examined in all cultivars were obtained from the 2 inoculation method in which hypocotyls excised from seedlings inoculated with $500{\mu}l$ of bacterial solution after drying in sterile cabin for 35 min were used.

A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater (가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구)

  • Lee J. H.;Ha J. M.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out for the purpose of determination of maintenance period and investigation of weak point due to freeze when the gas heater of KOGAS valve station Is not operated in winter season. 3-dimensional non-linear numerical simulation was conducted in order to predict the time and location which bath water in heater reaches to ice point. FLUENT V 5.0, commercial code, is used for thermal fluid flow analysis. We thought this was problem of heat conduction solving the energy equation and modeled gas heater by using the real geometry and scale for performing the 3-dimensional simulation. It was analyzed complex heat transfer phenomena considering convection due to air on surface, conduction in insulation material, natural convection of liquid in heater and heat loss through the pipe.

  • PDF

A High Voltage Poorer Supply for Electrostatic Precipitator with Superimposing Voltage Pulse on DC Source (펄스 및 직류 중첩형 전기집진기용 고전압 전원장치 개발 연구)

  • Kim, Jong-Soo;Rim, Geun-Hie;Lee, Sung-Jin;Kim, Seung-Min;Cho, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.624-630
    • /
    • 2001
  • The trend of the regulations on environmental issues are getting tight. Responding to this trend new technologies such as moving electrodes, wide pitch and pulsed power supply are also introduced in the electrostatic precipitator(EP) systems. The introduction of wide pitch and moving electrodes enhances the system performance of the EPs by improving air-flow and by improving the ash reentrainment on rapping. The power supplies for the EPs developed up to date include thyristor-based dc or intermittent type, SMPS(switching mode power supply) type and the pulsed-power supply type. The use of the pulsed ones is known to improve dust-collecting efficiency of high resistivity ash and reduces back corona occurrence in the collecting plate. There are two kinds of pulsed-power supplies; one with pulsed transformers and the other with direct dc switching devices. The latter uses rotary spark gap switches or semiconductor switches. Both have the merits and demerits: the spark gap switches are simple and robust but has short life time, hence, high maintenance cost, whereas the semiconductor switches have long life time but are costly. In this study, A high voltage power supply with superimposing voltage pulse on dc source was developed for EPs. This study describes circuit topology, operating principle of the scheme, and analysis of experimental results on Dong-Hae Power Plant. The pulsed power supply consists of a variable dc power supply with ratings of 60kV, 800mA and pulse generator which is made of high voltage thyristor-diode switch strings, an LC resonant tank and a blocking inductor. The pulse generator generates variable pulse-voltage up to 70kV using a high frequency resonant inverter with a variable dc source. Two prototypes were built and tested on 250MW DongHae power plant to verify the possibility of the commercial use and the normal operation in the transient states.

  • PDF

Numerical Simulation of Tsunami Force Acting on Onshore Bridge (for Tsunami Bore) (연안교량에 작용하는 지진해일파력에 관한 수치시뮬레이션(단파의 경우))

  • Lee, Kwang-Ho;Woo, Kyung-Hwan;Kim, Do-Sam;Jeong, Ik-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.1
    • /
    • pp.46-61
    • /
    • 2017
  • In the present work, the interaction analysis between tsunami bore and onshore bridge is approached by a numerical method, where the tsunami bore is generated by difference of upstream side and downstream side water levels. Numerical simulation in this paper was carried out by TWOPM-3D(three-dimensional one-field model for immiscible two-phase flows), which is based on Navier-Stokes solver. In order to verify the applicability of force acting on an onshore bridge, numerical results and experimental results were compared and analyzed. From this, we discussed the characteristics of horizontal force and vertical force(uplift force and downward force) changes including water level and velocity change due to the tsunami bore strength, water depth, onshore bridge form and number of girder. Furthermore, It was revealed that the entrained air in the fluid flow highly affected the vertical force.

A Study on Alternative Fan Selection and Verification in Military Electronic Equipment (방산용 전자장비의 팬 선정 및 검증에 관한 연구)

  • Jin, Sung Eun;Kim, Hwan Gu;Yoon, Eui Youl;Jeon, Hee Ho;Kim, Seung Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1091-1097
    • /
    • 2017
  • Sales of commercial-type cooling fans intended for application in military electronics are often discontinued during equipment production. This results in requirements for alternative fan selection as well as equipment performance and reliability tests, such as high-temperature operation testing. This study deals with alternative fan selection and verification methods that can be used during the production process. First, an alternative fan was selected by calculating the flow and pressure required to effectively cool the equipment, then the feasibility of the selected fan was verified using a reliable CFD heat dissipation analysis model. Following this, a high-temperature operation test was performed using the alternative fan in the equipment. Results demonstrated that the equipment satisfied its required function in a high-temperature environment, and the main parts as well as internal air temperature were found to be thermally stable.

A Study on Combusiton Properties of Natural Fiber Dust (천연섬유분진의 연소특성에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.3-10
    • /
    • 1999
  • We had investigated combustion properties of natural textile dusts. Decomposition properles of natural textile dusts scavenged by precipitator of spinning factoη were investigated using D DSC(Differential Scanning Calorimeter) and TGA(Thermogravimetric Analysis) by temperature c changes. Combustion pro야rties of natural textile according to size distribution and amount were c checked as temperature variation according to time using spontan$\infty$us ignition apparatus. M Moreover, combustion properties with blowing or without blowing condition were checked in order to investigate combustion prope$\pi$ies in spontaneous ignition apparatus according to flow c condition of air. As results of thermal analyses, increase in r머sing tern야:rature causes initial smold벼ng t temperature to move towards low temperature section 뻐d i띠디떠 smoldering temperature was d de$\sigma$eased more remarkably in atmosphere than in inert gas and that condition allowed heating v value to increase considerably. In addition, as amount and size distribution of natural textile d dusts were increased, i띠ti머 smoldering temperature was lowered. All of combustion forms were s smoldering combustion. Initial smold밍ing temperature was low more slightly with blowing c condition than without blowing condition in sp$\alpha$ltaneoUS ignition apparatus, which condition m made heatim;!; value high.

  • PDF

Spectroscopic Evidence of the Autoxidation Products Derived from Methyl Linolenate (Methyl Linolenate의 산화생성물(酸化生成物)에 대(對)한 분광학적(分光學的) 연구(硏究))

  • Ahn, Jong-Kyoon;Cho, Mi-Za;Kim, In-Sook;Oh, Sung-Ki
    • Applied Biological Chemistry
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 1989
  • The autoxidation products derived from methyl linolenate are isolated and characterized by using thin-layer chromatography, infrared, ultraviolet and nuclear magnetic resonance spectrometries. In addition, the propriety of the application of NMR spectrometry to the analysis of the autoxidation products is examined. Spectroscopic data indicate that the autoxidation of methyl linolenate produces hydroperoxides and trans, cis-substituted diene. The autoxidation products have a predominant cis, trans-conjugated diene system with some trans, trans-configuration. The spectroscopic data of ir, uv, and nmr are very consistent with each other, and further investigation of the multiplet region at $5.83{\sim}6.60ppm$ would be very helpful for the structural elucidation of the autoxidation products.

  • PDF