• 제목/요약/키워드: Air Conditioning Unit

검색결과 377건 처리시간 0.023초

NPE법을 이용한 절연재료의 유효열확산계수의 과도측정에 관한 연구 (A Study on the Transient Measurement of the Effective Thermal Diffusivity of Insulation Materials by NPE Method)

  • 임동주;배신철
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.243-255
    • /
    • 1990
  • The objective of this study is to present an efficient measurement method of the effective thermal diffusivity for the fibrous insulation material. The non-linear parameter estimation (NPE) method is adapted for this analysis because of its accuracy and its results are compared with those by other direct methods such as CTP, CHP and STD method. A experimental system is constructed with bell-jar vaccum chamber, diffusion pump, tube type furnace, control unit and data acquisition system included with A/D converter and IBM XT/AT personal computer. The typical results obtained from this study are as follows; 1) NPE method can be recommended as an useful and accurate method to measure the effective thermal diffusivity of insuation material because it is shown that the measurement error compared with those by other direct methods is reduced for standard material, NBS-1450b. 2) NPE method can minimize the effects of ill-measured temperature due to external disturbance, because the final value is found by point to point estimating. 3) NPE method dose not depend on the kinds of heat flux, since the surfac temperature are used to estimate the thermal diffusivity. 4) With NPE method, compared with the steady state method, a measuring time and a sample size could be reduced.

  • PDF

가스 인젝션을 적용한 전기자동차용 히트펌프의 난방성능 특성에 대한 실험적 연구 (An Experimental Study on the Heating Performance Characteristics of a Vapor Injection Heat Pump for Electric Vehicles)

  • 김동우;정종호;김용찬
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.308-314
    • /
    • 2014
  • A heat pump has been considered as a thermal management unit for electric vehicles, including the heating and cooling of the cabin. However, the heat pump shows performance degradation at low outdoor temperatures or high compressor speeds. In this study, a R-134a heat pump for an electric vehicle was designed to improve system efficiency, by applying vapor injection with an internal heat exchanger. The heating performance characteristics of the vapor injection heat pump were analyzed at various compressor speeds and outdoor temperatures. The vapor injection heat pump showed 13.3% COP improvement over the non-injection heat pump, when the heating capacity was fixed at 5.2 kW. In addition, the heating capacity of the vapor injection system increased by 9.6%, as compared to the non-injection system.

전동 블라인드 내장형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구 (Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System)

  • 최경석;손장열
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.429-435
    • /
    • 2010
  • Although recently revised building code requires 15~20% increased thermal insulation performance for window systems, since the code is focusing on winter heat loss, it is not satisfactory to contribute on reducing rapidly rising cooling load in summer. Window systems have great impact on building heat gain and loss. Therefore technological development for window system specialized in shading solar gain in summer is an urgent matter. This study evaluates the performance of sun shading and thermal insulation for blind integrated window system. Also, computer simulation evaluates the effect of heating and cooling energy consumption reduction for an individual unit(floor area of $85m^2$) of a multi-family housing. Physibel Voltra, a heat transfer analysis software, was used to analyse the effect of energy consumption reduction, and the energy load was converted to the cost to compare the actual effect of economical benefit.

복사열 반사판의 설계를 위한 광학적 해석 및 실험기법 (Optical Analysis and Experimental Method for Design of Radiative Thermal Reflector)

  • 정해용;송태호;유승열
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.563-569
    • /
    • 2008
  • Radiative, heating is suitable for outdoor heating system in windy and cold seasons. Optimal design of the reflector is very important to maximize heat transfer to a specific target area in the open space. The geometrical optical theory can be applied to analyze efficiency of the reflector. Commercial ray tracing computer programs are available only for limited geometries of the reflector. Alternatively, it may be designed and analyzed through an approximated simple lens theory. Two types of reflectors are analyzed using either of these methods. The key issue in this paper is to propose a new illumination experimental method for determination of the radiative efficiency. Optical light source and illuminometer are employed. The calculated efficiency of the reflector is compared with experimental one for checking the reliability. The relative errors between the experimental and analytical results are less than 5%, which proves the validity of this method. Based on these methodologies, a practical reflector and heating lamp unit is developed.

전도냉각형 펠티어 전류도입선의 최적화 (Optimization of Conduction-cooled Pottier Current Leads)

  • 정은수
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.764-771
    • /
    • 2005
  • A theoretical investigation for optimization of conduction-cooled Peltier current leads is undertaken. A Pottier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high Tc superconductor (HTS) lead in the order of decreasing thermoelectric tempera ture. Mathematical expression for the minimum heat flow per unit current crossing the TE metal interface and that flowing from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE-metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the 73 and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

대체냉매 HFC-134a의 모세관 성능에 관한 수치해석적 연구 (Investigation of the Performance of the Alternative Refrigerant HFC-134a through Capillary tube : Numerical Analysis)

  • 김창년;박영무
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.169-178
    • /
    • 1993
  • Performance charts of capillary tubes for R-134a are presented. The calculation is based on the one-dimensional, adiabatic flow through capillary tube. The length of capillary tube changes with inlet pressure, mass flux, inlet quality(or subcooling), and inside diameter. The length for R-134a is shorter by 12.5~23% than that for R-12 as mass flux varies, by 13~18.5% as inlet pressure changes, by 15~15.2% as inside diameter changes, and by 3.6~20% as subcooling(or quality) changes. In general, the length for R-134a is shorter than that for R-12 by 10~20%. Pressure drop per unit length for R-134a is greater than that for R-12 since specific volume of R-134a is larger that of R-12 and vapor pressure of R-134a is greater than that of R-12. Flash point of R-134a is ahead of that of R-12.

  • PDF

멀티패스 밀폐식 냉각탑의 관경변화 특성 (Characteristics of Closed Circuit Cooling Tower with Variation of Tube Diameter)

  • 심규진;이호생;김은필;윤정인;권오익
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.531-536
    • /
    • 2008
  • This paper presents experimental result of characteristics about Closed circuit Cooling Tower having a rated 2RT. The experimental apparatus has been set-up with a conventional type system. The test section is heat exchangers of cooling tower that consist of different vertical tubes, 15.88mm with 10 rows and columns and 19.05 mm with 8 rows and 12 columns. The main results were summarized as follows : The values of heat and mass transfer coefficients of cooling tower operating with two paths are higher than these with one path. Cooling capacity per unit volume using 15.88mm tubes are higher than 19.05mm tubes.

  • PDF

원관 주위 유하 액막에 의한 관 외벽에서의 입자 부착에 대한 실험 (An experiment of the particle deposition on a circular cylinder in a laminar flow)

  • 정종수;이윤표;정기만;박찬우
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.113-119
    • /
    • 2000
  • An experimental study has been carried out in order to investigate on a particle deposition on a circular cylinder surface. The present study is focused on the particulate fouling occurring in a heat exchanger for a seawater desalinization, in a laminar flow over circular cylindrical tubes. The objective is to investigate how NaCl concentration influences the $SiO2$ particle deposition on the surface of a glass circular cylinder. The NaCl concentration was changed from 0 g/L to 40 g/L. As the experimental results of $SiO2$ particle which is deposited on the glass circular cylinder surface showed, particle deposition rate per unit time increases rapidly with the increase of NaCl concentration between 0 g/L and 15 g/L. After the maximum of particle deposition rate was found at the NaCl concentration of 15 g/L, particle deposition rate remains unchanged or decreases gradually with the NaCl concentration from 15 g/L to 40 g/L. Also the $SiO2$ deposition rate of particles does not have serious variations with the position at present glass surface.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도와 보어홀 열저항에 미치는 영향 (The Effects of the Installation Conditions of Ground Loop Heat Exchanger to the Thermal Conductivity and Borehole Resistance)

  • 임효재;공형진;강성재;최재호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.95-102
    • /
    • 2011
  • A ground loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. A proper design requires certain site specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U tube configurations on ground effective thermal conductivity and borehole thermal resistance. In this study, thermal response tests were conducted using a testing device to 9 different ground loop heat exchangers. From the experimental results, the length of ground loop heat exchanger affects to the effective thermal conductivity. The results of this experiment shows that higher thermal conductivity of grouting materials leads to the increase effective thermal conductivity from 22 to 32%. Also, mounting spacers have increased by 14%.

기존 건물의 에너지 개수방법의 제안 및 사례연구 (Proposal of the Energy Retrofit in a Small Sized Office Building and its Application)

  • 정희규;박준원;이영재;송두삼
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.663-670
    • /
    • 2012
  • Recently, energy saving in building sector is of great important to meet national $CO_2$ reduction goals in Korea. In this sense, it is crucial to improve the energy performance for existing building. The energy efficiency investments, ESCO business, can be beneficial to expand the chance of energy retrofit for existing building. However, ESCO business hardly expand in Korea because it has many limitations in guarantee for energy saving. Also, it is more difficult to apply the energy retrofit measures in existing building than new building. Therefore, the retrofitting methods for existing small-and medium-sized buildings should be improved to initiate ESCO business and expand it in Korea. In this study, the energy retrofit methods for small sized office building were suggested and the case study for a small sized office building located in Suwon was accomplished.