• 제목/요약/키워드: Air Conditioning Unit

검색결과 378건 처리시간 0.017초

관 단면형상 변화에 따른 열전달 특성에 관한 수치해석적 연구 (Numerical Study for Heat Transfer Characteristics Varying Cross-Sectional Shape of a Tube)

  • 박훈채;최항석;김석준
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.560-566
    • /
    • 2012
  • Numerical study has been carried out to investigate heat transfer and pressure drop characteristics for streamlined shape tubes. The flow and thermal fields are investigated with varying diameter ratio of the tube ranging from 0.4 to 2.5 and Reynolds number ranging from 10,000 to 30,000. The results show that heat transfer per unit fan power is maximum at $D_2/D_1=0.8$. Furthermore, the heat transfer per unit fan power of streamlined shape tubes was compared with circular tube. The heat transfer per unit fan power of streamlined shape tube was larger than that of circular tube.

복합열병합 발전에 대한 전기 및 열 원가산정 (Cost Accounting of Electricity and Heat on Combined Cycle Cogeneration)

  • 김덕진;이근휘
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.673-682
    • /
    • 2004
  • The cost accounting of products on energy system is important for evaluating the economical efficiency and deciding the reasonable sale price. In the present, the suggested OECOPC method was applied to a combined cycle cogeneration, and each unit cost of electricity and heat products was calculated. In addition, the previous thermoeconomic methods were applied and calculated to equal system. As a result of comparing various methods, the unit costs by OECOPC method were calculated in the middle value of those. This result tells that OECOPC methods are most moderate. The suggested OECOPC method can apply any energy system. Hence this method is expected to make contribution to cost accounting on energy System.

동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가 (Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions)

  • 이승찬;김태안;태상진;정규하;문제명;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF

빙축열 에어컨의 동적 사이클 해석 (Dynamic Analysis of Cool Thermal Storage Air Conditioning System)

  • 고재윤;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In this study, dynamic characteristics analysis of AC system is investigated using a cool thermal storage system. A analysing program for cool thermal storage AC system is developed. The performances are studied by several variables and dynamic characteristics. Comparing the result at conventional operation condition with that at the condition using ice storage system, this study showed the effects of the sub cooled degree, superheated degree, efficiency of compressor and evaporating temperature. At the condition using thermal storage system, the thermal storage process was operated during midnight being not needed the cooling of the AC unit through the continuous running of the condenser. The refrigerant was sub-cooled using stored energy after being discharged from the air source condenser during the daytime. The COP was increased owing to the sub-cooling of refrigerant during daytime, thus the power consumption was effectively decreased.

냉방조건에서 실내기 위치 및 환기량에 따른 열쾌적성 및 유동 특성 (Thermal Comfort and Air Flow Patterns for Indoor Unit Positions and Ventilation Rates in Cooling Operation)

  • 고재윤;강태욱;박률
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.221-229
    • /
    • 2008
  • This study analyze indoor thermal comfort properties such as PMV, PPD and fluid variables when the cooling loads are light, occupant and ventilation. There are 6 cases to study for the indoor unit installation conditions and ventilation rates. Numerical method is used to study the indoor environmental properties and experimental study is adapted to analyze reaching time by variable cooling load conditions.

초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석 (A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types)

  • 노광철;이승철;오명도
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

퍼지룰을 이용한 멀티형 히트펌프 시스템의 제상 제어 (Fuzzy Defrost Control of the Multi-Type Heat Pump System)

  • 한도영;김경훈
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.711-716
    • /
    • 2000
  • A fuzzy defrost control algorithm for the multi-type heat pump system was developed. In the fuzzy defrost control algorithm, the air temperature difference at the outdoor unit and the refrigerant pressure difference at the compressor were used as input variables, and the defrost starting time and the defrost time interval were used as output variables. This fuzzy algorithm was applied to the multi-type heat pump system and tested in the five dynamic environmental chambers. Test results show that the newly developed control algorithm is more effective than the conventional control algorithm in the removal of frost formed at the outdoor unit of the heat pump.

  • PDF

실험동물 사육실에서의 Exhaust Filter Unit의 악취제거성능에 관한 실험적 연구 (An Experimental Study on the Deodorization Performance of Exhaust Filter Unit in a Laboratory Animal Breeding Facility)

  • 권순욱;홍진관
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.194-200
    • /
    • 2013
  • In this study, an exhaust filter unit for removing bad smells is designed and manufactured to understand the characteristics, damages, and effects on humans and animals of bad smell substances in laboratory animal breeding facilities. Using the exhaust filter unit, a deodorization performance test using ammonia gas, as a typical bad smell in an animal breeding room, was carried out for three types of activated and impregnated charcoal filters. The experimental results showed that the pressure loss of the HEPA and carbon filter was increased with flow rate and that the average deodorization performance for the case where an impregnated carbon filter was installed was a maximum value of between 93 and 96%, with various fractional flow rates ranging from 1,500 to $3,500m^3/h$ in a laboratory animal breeding room. The experimental results will also be used for the design and manufacture of a practical and efficient exhaust filter unit to cope with bad smell problems in animal breeding facilities.

공동주택의 열사용량원단위 산정에 관한 연구 (A Study on the Calculation of Thermal Consumption Unit of Apartment)

  • 이왕제;강은철;이의준;신우철
    • 설비공학논문집
    • /
    • 제26권8호
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

에어믹서가 설치된 공조기 혼합실 내의 온도분포에 관한 실험적 연구 (An Experimental Study of Temperature Profiles in Mixing Zone of AHU with an Air Mixer)

  • 박권종;이석준;장영근
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.999-1006
    • /
    • 2006
  • A study of temperature profiles in mixing zone of AHU (air handling unit) can contribute greatly to enhance performance of AHU system, so the study on the temperature distribution between RA (return air) and OA (outdoor air) is important to analyze the mixing characteristics in a mixing zone of AHU. Accordingly, the temperature profiles during RA (return air) and OA (outdoor air) supply process into mixing zone of AHU with an air mixer are studied experimentally. The effect of air mixer, OA temperature and RA/OA flow rate are studied in detail. In this study, the results show that the mixing efficiency is all high for installed the air mixer. The more OA temperature increase and OA flow rate decrease, the more mixing efficiency is high.