• 제목/요약/키워드: Air Conditioning Unit

검색결과 377건 처리시간 0.022초

폐쇄형 묘생산 시스템에서 감자 플러그묘의 생장에 미치는 광합성유효광양자속의 영향 (Growth of Potato Plug Seedlings as Affected by Photosynthetic Photon Flux in a Closed Transplants Production System)

  • 김용현;김현준;이지원;김정만
    • Journal of Biosystems Engineering
    • /
    • 제33권2호
    • /
    • pp.106-114
    • /
    • 2008
  • This study was performed to analyze the distribution of air current speed, $CO_2$ concentration, and photosynthetic photon flux (PPF) in a closed transplants production system (CTPS) for producing quality transplants. And the effect of PPF on the growth of potato (Solanum tuberosum L. cv. Dejima) plug seedlings was analyzed. Uniformity of the air current speed in CTPS was improved by installing perforated floors in duct for air circulating and by adjusting of air flow rate of the fan connected to air conditioning unit used in this study, Measured $CO_2$ concentrations were measured $409{\pm}13$, $950{\pm}25$, and $1,550{\pm}35\;{\mu}mol{\cdot}mol^{-1}$ for setting values of 400, 950, and $1,550\;{\mu}mol{\cdot}mol^{-1}$, respectively. Uniformity of PPF by adding each one the single fluorescent lamp of 20 W at both ends of the single fluorescent lamps of 40 W was highly improved. While the average PPF measured under the twin fluorescent lamps of 55 W installed at regular intervals of 10 cm was decreased by increasing the vertical distance from the lighting sources, the ratio of average PPF measured at both ends to PPF measured in the center was 74-79%. Five levels ($100{\pm}9$, $150{\pm}14$, $200{\pm}17$, $250{\pm}24$ and $300{\pm}31{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) of PPF were provided to investigate the effect of PPF on plant height, fresh weight and dry weight of potato plug seedlings produced in CTPS. Plant height was decreased by increasing PPF. Maximum fresh weight and dry weight were shown under PPF of $250{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Thus PPF of $250\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was enough to produce quality potato transplants under air temperature, photoperiod, and relative humidity of $20^{\circ}C$, 16/8 h, and 70%, respectively. It was concluded that quality indices such as plant height, fresh weight and dry weight could be improved by illuminating of adequate PPF from artificial lighting sources.

Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

  • Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.287-295
    • /
    • 2013
  • PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.

간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구 (Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.743-749
    • /
    • 2015
  • 본 연구의 목적은 간접식 증발냉각 장치의 성능을 예측하고, 장치를 공기조화기의 배기열 회수에 적용하였을 경우의 에너지 절약효과를 분석하는 것이다. 플라스틱 열교환기를 사용한 간접식 증발냉각장치의 성능 상관식을 여러가지 조건에서 얻어진 실험 데이터로부터 구하였으며, 이 상관식을 이용하여 환기와 외기의 조건을 변화시켜가면서 장치의 성능변화를 예측하였다. 또한 간접식 증발냉각장치의 배기열 회수에 의한 에너지 절약효과를 우리나라 몇개 도시의 표준기상데이터를 사용하여 분석하였다. 여름철 배기열 회수를 위한 현열냉각장치의 사용율은 평균 44.3%이며 증발냉각장치의 사용율은 96.7% 이다. 증발냉각장치의 배기열 회수에 의한 에너지 절약은 현열냉각장치에 비해서 훨씬 높으며, 서울의 경우 약 3.89 배로 나타났다.

곡류 및 버섯류의 평형함수율 및 박층건조방정식에 관한 연구(II) - 표고버섯에 대하여 - (Equilibrium Moisture Contents and Thin Layer Drying Equations of Cereal Grains and Mushrooms (II) - for Oak Mushroom (Lentinus erodes) -)

  • 금동혁;김훈;홍남운
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.219-226
    • /
    • 2002
  • Desorption equilibrium moisture contents of oak mushroom were measured by the static method using salt solutions at flour temperature levels of 35$\^{C}$, 45$\^{C}$, 55$\^{C}$ and 6$\^{C}$ and five relative humidity levels in the range from 11.0% to 90.8%. EMC data were fitted to the modified Henderson, Chung-Pfost, modified Halsey and modified Oswin models using nonlinear regression analysis. Drying tests far oak mushroom were conducted in an experimental dryer equipped with air conditioning unit. The drying test were performed in triplicate at flour air temperatures of 35$\^{C}$, 45$\^{C}$, 55$\^{C}$ and 65$\^{C}$ and three relative humidities of 30%, 50% and 70% respectively. Measured moisture ratio data were fitted to the selected four drying models(Lewis, Page, simplified diffusion and Thompson models) using stepwise multiple regression analysis. The results of comparing root mean square errors for EMC models showed that modified Halsey was the best model, and modified Oswin models could be available far oak mushroom. The results of comparing coefficients of determination and root mean square errors of moisture ratio for four drying models showed that Page model were found to fit adequately to all drying test data with a coefficient of determination of 0.9990 and root mean square error of moisture ratio of 0.00739.

익형의 기하학적 조건에 따른 축류팬의 성능에 관한 연구 (Effects of geometric conditions of blade on Performance of Axial Pan)

  • 안은영;김재원;정은주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.25-29
    • /
    • 2005
  • Axial fan is used for the supplement of large amount of flows. Axial blowers show relatively high efficiency of the system. The present model of axial fan is for cooling a condenser in an air-conditioning unit that exhibits tendency toward compact size. In order to realize the compact model, the width of an axial blade should be cut down in axial distance. Main interest lies on the performance of the axial blowing system with blades having shorter chord length. One of the important design parameters for axial fan is the shape of the blades of it. Design of blades includes the cross-sectional shape and its dimension, including the chord length. We consider two types of blades; one is NACA airfoil with normal chord length and the other is with shortening chord length by $10\%$ of normal airfoil. Axial blower with the modified blades is essential for the compact model of an air-conditioner. The other design parameters are same in the two cases. Using a wind tunnel follows ASHRAE standards carries out evaluation of performance of the system. Detail of flows around the blades is prepared by velocity measurements using PIV. According to performance estimation, the axial blower with short chord blade show quite close to the performance results, including flow rate and pressure rise, of the standard one. The reason of the two similar results is that the flowpatterns depend on Reynolds number based on the chord length of a blade. In this investigation, the critical chord length is found, in which the flows near the airfoil are so unstable and the performance of the system is decreased. A series of figures is for the detail information on the flow.

  • PDF

하이브리드 전기추진시스템 구축을 위한 SEIG의 출력 특성 분석 (Behavior Analysis of a Self Excited Induction Generator with Various Loads for a Hybrid Electric Propulsion System)

  • 양주호;최교호;이재민;정석권
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.41-47
    • /
    • 2018
  • This paper analyzes the output characteristics of a self excited induction generator with isolated mode according to change of its speeds and loads for building a hybrid electric propulsion system in special purpose ships by using power take off. The induction generators are being considered as an alternative choice to the well-developed generators because of their lower unit cost, inherent ruggedness, operational and maintenance simplicity. However, the generator working by stand alone has a few problems that the reactive power is required to establish the air gap magnetic flux, and the induced voltage and magnetizing current fluctuate when the load is varied. In spite of its advantages, basic design data of the capacitor bank and behaviors of the output characteristics of the generator are not sufficient for the system. Based on the operating condition(speed range of main engine) of the target boat, a reduced experimental equipment system was constructed to analyze the output characteristics of the SEIG. And a suitable capacitor bank of a stand-alone generator and its output characteristics under various loads was investigated in detail through these experiments. According to the experimental result, it was confirmed that the capacitor bank should be $70{\mu}F{\sim}100{\mu}F$, and the proper SEIG induced voltage should be DC 80 V ~ 250 V in order to storage electrical energy into a battery.

왕복동식 압축기의 스너버내 맥동압 분포 (Pulsatile Pressure Distribution on the Snubber of Reciprocating Compressor)

  • 이경환;;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.606-611
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. This study discusses pressure pulsation phenomena occurred in a reciprocating compressor system. An experiment applied air compressor unit, as pulsating pressure generator, has been done. The compressor was connected sequentially to a snubber model and pressure tank. Sensor probes were placed on the inlet and outlet pipes of snubber. Compressor was driven by a motor controlled by a frequency regulator. The experiment was conducted by adjusting the regulator at 40Hz. General information about an internal gas flow can be achieved by numerical analysis approach. Information of the velocity, pressure and turbulence kinetic energy distribution are presented in this paper. Based on this result, the design improvement might be done.

  • PDF

포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석 (Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era)

  • 이세진;이원석;김은석;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권1호
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가 (Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus)

  • 서정기;위승환;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.655-663
    • /
    • 2016
  • 최근, 전 세계적으로 온실 가스 증가에 따른 기후 변화에 대한 문제가 논의되고 있다. 그중, 건축물에서의 에너지 소비량은 전체 에너지 소비량의 40%까지 증가할 것으로 예상된다. 따라서 건축물에서의 에너지 소비량 절감에 대한 노력이 필요한 실정이다. 본 연구에서는, 건물에너지 절감에 효과적으로 기여하는 재료 중 하나인 목재를 이용하여, 목질 제품 구성에 따른 중부지방과 남부지방의 난방에너지 요구량에 대하여 시뮬레이션을 통해 분석하였다. 시뮬레이션 도구는 미국 에너지부(Department of Energy)가 BLAST와 DOE-2의 장점을 결합해 만든 동적 에너지 해석 엔진인 EnergyPlus를 이용하였다. EnergyPlus는 다양한 건물 및 HVAC 시스템 구성요소(Object)에 대한 입력항목(Field)을 가지고 있으며, 특히 건물, 공조시스템, 열원기기 사이의 피드백을 통해 통합된 동시계산을 수행하며, ASHRAE Standard 140-2007 표준에 따라 상용 프로그램 간의 비교를 통해 검증된 프로그램이다. 시뮬레이션을 위한 기상데이터는 EnergyPlus에서 제공하는 IWEC 인천 지역과 광주 지역의 epw 형식 기상데이터를 이용하였다. 대상 모델은 한국농어촌공사에서 제시한 2012년 농 어촌주택 표준설계도면 중 '농림-12-26-가' 유형을 이용하였으며 총 10개의 실로 구성되어 있다. 시뮬레이션 분석 결과, 중부지방과 남부지방 별 목질 제품의 적용 범위를 실내마감재, 실외마감재, 창호, 목구조로 단계적으로 변경해 지역에 따라 각각 16 Case의 시뮬레이션을 수행한 결과 실내외의 마감재로 목재를 사용한 것만으로도 에너지 성능이 향상된 것을 확인할 수 있었다.

열린 자기차폐실의 심자도 시스템 (Magnetocardiography System in Open-door Magnetically-shielded Room)

  • 김진목;이용호;권혁찬;유권규;김기웅;박용기
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.50-55
    • /
    • 2007
  • We have installed a 61-channel magnetocardiography (MCG) system inside a magnetically shielded room (MSR) with a size of $2.4\;m\;{\times}2.4\;m\;{\times}2.4\;m$. The MCG system consists of 1st-order axial gradiometers containing double relaxation oscillation SQUIDs (DROSs) with pick-up coils of a base line of 70 mm. The MSR holds a shielding factor of 50 at 0.1 Hz and 10000 at 100 Hz, when its door in the middle on a front wall is closed. On opening the MSR door, we have obtained the characteristics of the MCG system with a 2.9 Hz noise generated from an air conditioning unit at 13 m distance off the MSR. In an open-door MSR ($140^{\circ}$ opening), a noise at the center channel increases up to $700\;fT/Hz^{l/2}$ at 2.9 Hz and $1.7\;pT/Hz^{1/2}$ at 60 Hz. MCG signals for a healthy human do not show distortion until the door opens to $45^{\circ}$, but show the effect of noise when the door opens further at $90^{\circ}$ and $140^{\circ}$. With the door opens to $45^{\circ}$, MCG measurement can be performed with ease of door operation and without creating claustrophobia for the patient.

  • PDF