• 제목/요약/키워드: Air Conditioning Noise

검색결과 174건 처리시간 0.02초

천장형 시스템 에어컨의 음향 특성 (Acoustical Characteristics of System Air Conditioners Installed in the Ceiling)

  • 김수연;유진;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.662-665
    • /
    • 2005
  • In this study acoustical characteristics of system air conditioner in different ceiling systems was investigated in anechoic and real conditions. Same Types of air conditioners were installed in two different rooms. The results showed that motor's tonal component was emphasized at near fart of air blast blower in the exposed type while fan's harmonic component is emphasized rather in the enclosed type. This confirms tile result of acoustical intensity mapping which showed that Intensity level of 125Hz octave band increased in the exposed type while there was no noticeable difference at the frequency band in the enclosed type.

  • PDF

UPS 기능을 갖는 A/C Blower용 Inverter 시스템 개발 (Development of the Inverter System with UPS Function for the Air-Conditioning Blower)

  • 임승범;이윤하;지준근;목형수;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.345-346
    • /
    • 2010
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations against to AC 380V input. Therefore, the efficiency of the system is reduced and noise occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

  • PDF

온돌 난방분배기의 개도조정 (Adjustment of Valve Opening in Ondol Hot Water Distributor)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

환기용 덕트내의 전달소음 특성에 관한 연구 (A Study on the Transmitted Noise Characteristics through the Ventilating Duct)

  • 최한림;김경환;최호선;오세기;정백영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

품질공학(TAGUCHI METHOD)에 의한 COMPRESSOR의 성능과 소음에 관한 연구 (Application of Quality Engineering for EER and Noise of Compressor)

  • 박성근;임금식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1994년도 추계학술대회논문집; 한국종합전시장, 18 Nov. 1994
    • /
    • pp.148-154
    • /
    • 1994
  • The dynamic analysis of S/N ratio in this study to improve EER has proven to be very effective. The optimized condition can improve EER during the developing process without increasing noise and any other investment. If this method is used widely to design valve systems of compressor for refrigeration and air-conditioning, output capacity will be greatly increased for industry.

  • PDF

벽체 매립형 환기용 팬 성능개선에 관한 연구 (Study on the Performance Improvement of Ventilation Fan Installed in Walls of Underground Parking Lots)

  • 권용일
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.206-211
    • /
    • 2014
  • The objective of the present study was to identify ventilation problems, and also to suggest new axial fan systems for the improvement of IAQ in the underground parking lots. Numerical results for air mean-velocity, local mean age, and sound power level are presented along with some of fan angles. The results showed the influence of airflow patterns on the fan performances installed in the underground parking lots. Discharge air volume is increased with the angle of the blade. And also, the main factors affecting the noise of the ventilation fan was found to be a rotational speed.

평행류 열교환기가 적용된 무선통신 중계기 냉각용 슬림형 공조기 (Slim Air-Conditioner with Parallel Flow Heat Exchangers for Cooling of Telecommunication Cabinet)

  • 조진표;김내현
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.87-93
    • /
    • 2009
  • Slim telecommunication cabinet cooler, equipped with parallel flow heat exchangers and operating with R-22, is developed. The performance is compared with imported one, equipped with fin-tube heat exchangers and operating with R-134a. Test results show that the newly-developed cooler increases the cooling capacity by 6% and EER by 33%. The refrigerant charge for the developed cooler is 500g compared with 1250g for the imported one. The adoption of parallel flow heat exchanger appears to have reduced the refrigerant charge. In addition, it is shown that the reduced air flow rates through parallel heat exchangers as compared with those through fin-tube heat exchangers are beneficial to the reduction of the equipment noise.

유한요소 해석 기반 자동차 공조용 DC모터 토크 리플과 소음 저감에 관한 연구 (FEA-based Torque Ripple and Noise Reduction of DC Motor for Automotive Air-Conditioning)

  • 황명환;김동현;양승진;차현록;한종호
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1895-1898
    • /
    • 2017
  • This paper discusses methods for the torque ripple and noise reduction of DC motors for automotive air-conditioning based on electromagnetic field analysis. The target of the motor is a blower motor, and to reduce cogging torque and the torque ripple, the optimum model was selected by deforming the brush or commutator shape. In addition, to reduce the cogging torque, the model design was carried out by applying the skew method and the magnetization method of a magnet to the rotor. For optimization, the shape, material, and drive system of the motor were selected using an electromagnetic field as the analysis tool, and the method of reducing the cogging torque was applied to 4-pole, 12- and 13-slot motors considering the mechanical part. Lastly, this paper confirmed thatthemethod, which proposed how much noise, cogging torque, and vibration are reduced, improves through practical analysis.