• Title/Summary/Keyword: Air Conditioning Energy

Search Result 1,912, Processing Time 0.03 seconds

A Simulation Appraisal of Energy Performance in Office Building by Different Types of Air-Conditioning (공조방식에 따른 사무소 건물의 에너지 성능 평가)

  • Choi, Jong-Dae;Choi, Dong-Suk;Yun, Geun-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.612-620
    • /
    • 2012
  • High economic growth causes increase of the building energy consumption. The energy consumption for HVAC system accounts for 40~50% of the whole building consumption. The trend for building is large-scale and high-rise. Because of the trend, the energy consumption is becoming bigger than before. Nowadays, HVAC system design are recognized as the solution for a energy-saving. This paper is focused on the energy performance evaluation of central air-conditioning system(water-based) and system air-conditioning that were applied to the office building. The systems are modeled and simulated by using EnergyPlus Software 6.0. After the Simulation, annual cooling and heating energy consumption were calculated. It was found that the system air-conditioning can reduce the energy consumption approximately 55.24% annually compared with the central air-conditioning system(water-cooled). In addition, about 46.13% of annual operating costs can be reduced by use of system air-conditioning.

Study on the Personal Air-Conditioning System Considering Human Thermal Adaptation (인간의 열적 적응성을 고려한 퍼스널 공조시스템의 개발)

  • 송두삼
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.524-532
    • /
    • 2003
  • In this paper, a personal air-conditioning system considering the human thermal adaptability is analyzed. Although the conventional personal air-conditioner was proofed to be satisfactory in providing for the thermal comfort, it is being questioned on the term of its energy efficiency. Therefore, it is important and urgent to develop new types of personal air-conditioning system with sustainable control strategy that can ensure energy saving and thermal comfort simultaneously. In this study, we first examined the problems of the conventional personal air-conditioning system with field interview and laboratory experiment in terms of usage, management and thermal comfort, and proposed the energy-saving personal air-conditioning system considering the human thermal adaptation. Then a laboratory experiment was performed to analyze the characteristics of the human thermal comfort under severe indoor thermal conditions, which were controlled using a new personal air-conditioning unit designed according to the proposal. The results help to illustrate the alleviation effect of the new personal air-conditioning system, and indicate that the thermal alleviation time is useful to maintain the thermal comfort with efficient usage of energy.

An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Kang, Shin-Young;Son, Seung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

Technology of Air-Conditioning System by Ocean Thermal Energy near Busan Coast (부산지역 해수온도차이용 냉난방기술)

  • Oh, Cheol;Kim, Meong-Whan;Lim, Tae-Woo;Choi, Young-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.350-355
    • /
    • 2009
  • Air-conditioning system by ocean thermal energy has been developed in the areas of Europe, North America and Japan because there are abundant amount of thermal energy potential in the ocean and permanent free use for the thermal energy using the air-conditioning system. In the case of domestic ocean thermal energy resource, ocean thermal energy potential exists about 27,155Tcal/year and totally 20,285Tcal/year of possible thermal energy use by heat pump, which are reported from the survey of the 7 domestic near shore cities. Present study is aimed to survey the current development status of domestic and overseas air-conditioning system by ocean thermal energy, especially, for the air-conditioning facility technologies using sea water.

  • PDF

Development of HVAC System to Lower the Conveyance Energy and Building Height (반송동력과 건물층고 저감형 공조시스템 개발)

  • 김정엽;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

Analysis of Energy Reduction of Free Cooling System with Regions of South Korea (지역별 프리쿨링 시스템의 에너지 절감 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.82-88
    • /
    • 2014
  • Using low outdoor temperature, free cooling system is used in a data center or industrial air-conditioning for energy saving. Because use of IT equipment has increased in some office building recently, there is a growing trend towards using free cooing system. Free cooling system performance is influenced by outdoor temperature. Therefore the performance is different with regions. In this study, performance characteristic of free cooling system is analysed and energy reduction is compared with some regions. Selected regions are 4 cities; including Ulsan analyzed in preceding research, Seoul, ChunCheon and Daejeon. The Aspentech software HYSYS 8.0v was used to conduct the analysis of free cooling system based on temperature per hour of 4 cities in 2013, respectively. The main result is following as. Free cooing system in this study has energy saving effect when outdoor temperature below $7^{\circ}C$. Becuase temperature of Chuncheon is relatively low, using free cooling system can conserve most air-conditioning energy. Energy reduction amount of Seoul is 11%, Chuncheon is 17.5%, Deajeon is 15%, Ulsan is 14%. In case of large scale of air-conditioning, it is reasonable to use free cooling system although the system is used in Seoul.