• Title/Summary/Keyword: Air Conditioner Noise

Search Result 142, Processing Time 0.023 seconds

Placing Constrained Layer Damping Patches Using Reactive Shearing Structural Intensity in Order to Reduce the Radiated Sound Power of a Air-Conditioner Outdoor Unit (반동 전단 구조 인텐서티 측정에 의한 제진재 적용과 그에 따른 에어컨 실외기 구조 방사 소음 저감)

  • 김규식;강연준;진심원;정인화;이정우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.333-337
    • /
    • 2003
  • The use of reactive shearing structural intensity to place small patches of constrained layer damping material in order to achieve the largest reduction in the radiated sound power of Air-conditioner outdoor unit is described. The normal surface velocity of each panel was measured using a laser doppler vibrometer. Experimental results indicated that patches of constrained layer damping material placed over areas of high reactive structural intensity reduced the radiated sound power significantly more than patches of the same area placed over areas of low reactive structural intensity

  • PDF

Shape Optimization of an Air Conditioner Piping System (에어컨 배관 시스템의 형상 최적설계)

  • Min, Jun-Hong;Choi, Dong-Hoon;Jung, Du-Han
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1151-1157
    • /
    • 2009
  • Ensuring both product quality and reducing material cost are important issue for the design of the piping system of an air conditioner outdoor unit. This paper describes a shape optimization that achieves mass reduction of an air conditioner piping system while satisfying two design constraints on resonance avoidance and the maximum stress in the pipes. In order to obtain optimized design results with various analysis fields considered simultaneously, an automated multidisciplinary analysis system was constructed using PIAnO v.2.4, a commercial process integration and design optimization(PIDO) tool. As the first step of the automated analysis system, a finite element model is automatically generated corresponding to the specified shape of the pipes using a morphing technique included in HyperMesh. Then, the performance indices representing various design requirements (e.g. natural frequency, maximum stress and pipe mass) are obtained from the finite element analyses using appropriate computer-aided engineering(CAE) tools. A sequential approximate optimization(SAO) method was employed to effectively obtain the optimum design. As a result, the pipe mass was reduced by 18 % compared with that of an initial design while all the constraints were satisfied.

Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Noise Characteristics (에어컨 실외기용 축류홴의 성능에 관한 연구: 소음 특성)

  • Kim, Yong-Hwan;Lee, Jang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.29-34
    • /
    • 2010
  • In this paper, aerodynamic noise of axial flow fans for outdoor unit of air-conditioner was analyzed by both experiment and numerical simulation. The three-dimensional incompressible turbulent flow was predicted by the commercial computational fluid dynamics code SC/Tetra, while the aeroacoustic noise of an axial flow fan was predicted by FlowNoise. Computations and experiments were performed with two types of axial flow fans, in which very different noise source distributions were presented. The results obtained from this study are expected to show the way to reduce the noise of axial flow fans in industrial applications.

Study on Low Frequency Characteristics of Rotary Compressor (로터리 압축기 저주파 특성에 관한 연구)

  • Kwon, Byoung-Ha;Park, Sin-Kyu;Hwang, In-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.857-862
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000Hz is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. The low frequency band noise is significantly reduced by proposed designs.

  • PDF

A Study on the Measurement of Dynamic Properties of the Rubber Mount in the Impeller Fan Motor of the Air-conditioner (에어컨 실내기 팬 모터용 방진고무의 동특성 측정에 관한 연구)

  • Choi, Hyun;Kim, Jun-Woo;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.185-190
    • /
    • 2001
  • The structure borne noise of the air-conditioner, which degrades the noise quality, is hardly reduced by the general noise treatments. It can be effectively reduced by eliminating the structural vibration which the noise originates from. The rubber vibration isolator prevents the dynamic force induced by the fan driving motor from exciting the chassis structure, which finally reduces the structure borne noise. The dynamic properties of the vibration isolation system such as the natural frequency of the vibration isolation and loss factor of the rubber isolator, need to be experimentally evaluated. In this paper, these dynamic properties were obtained by the resonant method using the impact hammer for 3 types of the isolator specimens. It is known that the isolation natural frequency of the axial direction of the rubber isolator is two times higher than that of the radial direction, and is proportional to the hardness of the rubber specimen.

  • PDF

Analyzing for Refrigerant Induced Noise for Split type Air Conditioner Indoor Unit (분리형 에어컨의 실내기 냉매 소음 저감 분석)

  • Han, Hyung-Suk;Aoyama, Shingeo;Mo, Jin-Yong;Lee, Jae-Kwon;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.421-426
    • /
    • 2005
  • For the air-conditioner, refrigerant induced noise and vibration should be the problem when it reduced airflow rate in order to reduce the noise at low mode. With the test, it could be verified that one of the main reason for refrigerant induced noise were the velocity and flowing induced force of the refrigerant at the inlet of evaporator. So in order to reduce this velocity with same mass flow rate of refrigerant, quality at the evaporator inlet should be minimized. And in order to reduce flowing induced force of the refrigerant, flowing direction change should be eliminated. So in this paper, it would like to review the characteristics of refrigerating cycle at first and find how the quality and flowing induced force can be minimized.

  • PDF

Study on the Development for Low Noise Indoor and Outdoor Package Air-Conditioner (저소음 패키지 에어컨 실내외기 개발에 관한 연구)

  • Kim, Jang-Kweon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1913-1920
    • /
    • 1996
  • The purpose of this study was to reduce the airborne noise emitted from the package air-conditioner(PAC) therefore, the optimim design melthods of the fans and the flow-paths were investigated experimentally through the anlaysis of the nose problems caused by the conventional PAC system, and the fan performance tests and the systme resistance measurements of the parts which belong to the flow-paths of the PACwere used to study these noise problems. As a results, through the optimized flow-paths of the new PAC system with the lowset system resistance, and by adjusting and matching the operating point of each fan to each PAC system, the airborne noise reductions from the new indoor PAC and the outdoor one were achieved upto 5.5 dBA and 6.6 dBA respectively in overall noise level as compared with the conventional PAC system.

Experimental Analysis Using Taguchi Method on the Resonator in the Rotary Compressor for Air Conditioner (다구찌 법을 이용한 에어컨용 회전압축기 공명기에 관한 실험적 연구)

  • 이병찬;김진동
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.1
    • /
    • pp.3-9
    • /
    • 2004
  • This paper introduces the experimental analysis of the resonator in the rolling piston type compressor for air conditioner. The resonator located between cylinder and hearing is a major factor in the noise reduction of the rotary compressor. Several shapes for the resonator which can be built in the space limitations are derived. Then optimal resonator type for the noise reduction is determined by noise tests. 6 design parameters of the type are found and optimal level for each design factor is deduced from Taguchi method.

Environmental Noise Assessment of Outdoor Air-conditioner Fans by Using Ray Tracing Method (레이추적법에 의한 에어컨 실외기의 환경소음 예측에 관한 연구)

  • Choi, Jin-Kwen;Chang, Seo-Il;Lee, Jin-Kyo;Lee, Soo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1444-1449
    • /
    • 2000
  • This environmental influence of the noise produced by a number of air-conditioner out-door units in a multi-unit housing is predicted and evaluated. The method based on Ray tracing theory and mirror image source theory is utilized. Each ventilation window in a machine room is considered as a sound source which contributes to the overall noise level of the surrounding environment. The adopted method has been found a very efficient tool to assess the environmental noise impact.

  • PDF