• 제목/요약/키워드: Air Conditioner Noise

검색결과 142건 처리시간 0.025초

교실 음향에 대한 에어컨 소음의 영향 (The Effects of Air Conditioner Noise on Classroom Acoustics)

  • 김수연;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.176-179
    • /
    • 2005
  • A case-study in classroom acoustics was conducted and the effects of two types(system air conditioner and packaged air conditioner) of air conditioner were investigated. Acoustical measurements were made in two different classrooms. Each classroom has different acoustics showing sound quality of air conditioner. Mental concentration test was conducted to evaluate the effects of air conditioner noise with different sound presure level(dBA). Speech intelligibility test was also planed with adopting Korean phonetic balanced words.

  • PDF

시스템 에어컨에 의한 실내 소음 평가 및 개선 설계 (Estimation of the Noise Caused by the System Air Conditioner and its Improvement)

  • 이제원;주재만;오상경;송용재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF

에어컨 실내기에서 발생하는 충격 소음원의 위치 추정 (Source localization of impact noise on an indoor unit of air-conditioner)

  • 최영철;김양한;이종구;김구영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

실험적 방법을 통한 에어컨 실내기의 소음원 검출에 관한 연구 (A Study on Noise Identification of Indoor Air-conditioner Using Experimental Methods)

  • 이성진;오재응;이정윤;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.87-87
    • /
    • 2004
  • An air-conditioner has various noise sources such as a fan noise, a motor noise, and a vibration induced noise. To reduce these noise effectively, noise sources must be identified. Especially in this paper, the structure borne sound radiated from the motor bracket of the indoor air-conditioner is considered. To do this, the operational deflection shape, which is used for understanding of the behavior of the motor bracket at a particular frequency, is obtained and compared with the sound intensity, which is used for the noise identification. Through this study, the noise sources of indoor air-conditioner are defined and the effective noise reduction method is proposed.

  • PDF

에어컨 실외기 받침대의 구조진동 특성 (Structural Vibration Characteristics for an Outdoor Units Support of an Air-conditioner)

  • 류봉조;송선호;임채욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.215-217
    • /
    • 2008
  • This paper deals with the structural vibration characteristics for an outdoor units support of an air-conditioner. Even though main noise sources are compressor noise and fluid noise which is caused by the fan, the structural modification of the outdoor units support may affect vibration and noise. In this paper, damping ratios for two kinds of an outdoor units support of an air-conditioner are measured through the modal testing. In order to reduce the structural borne noise due to an outdoor units support of an air-conditioner, four kinds of rubber materials are selected and tested.

  • PDF

차량용 에어컨 부밍 소음의 전달 특성에 관한 연구 (A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise)

  • 임승택;주경훈;안휴남;박영덕;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

Reduction of the Refrigerant-Induced Noise from the Transition of Flow Pattern by Decreasing Tube Diameter

  • Takushima, Akira;Han, Hyung-Suk;Jung, Wei-Bong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.37-44
    • /
    • 2009
  • It is well known that a refrigerant-induced noise is caused by two-phase flow in the indoor unit of a heat pump air-conditioner. Especially when the flow pattern in a pipe is intermittent flow, the irregular noise occurs frequently. But it is very difficult to avoid this kind of the noise for the application of air-conditioner. Therefore, in this research, the flow patterns at two-phase flow state in a pipe of the indoor unit for the air-conditioner are researched using cycle simulator at typical cycle conditions. In order to find the relationship between refrigerant-induced noise and flow pattern, the noise patterns are investigated with respect to the estimated flow pattern from the various flow pattern maps. Base on the estimations of the flow patterns by those maps, the refrigerant-induced noise is evaluated as decreasing tube diameter, which can transit the flow pattern from slug to annular flow.

저소음 패키지형 공기조화기의 실내기 개발에 관한 연구 (Study on the Development for Low Noise Indoor Unit Package Air-Conditioner)

  • 이재효;조성철;김태헌
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.518-523
    • /
    • 2003
  • The purpose of this study was to reduce the noise emitted from the package air-conditioner. The optimum design methods of the fans ware investigated experimentally through the analysis of noise problem caused by the conventional PAC system. New PAC system had decreased 6 dBA in overall noise level as compared with the conventional system by various technology.

가정용 에어컨 실외기의 기동 소음 분석 (The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner)

  • 손영부;이승목;하종훈;이병철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

축류팬 및 슈라우드 개선을 통한 공조기 저소음화에 대한 연구 (Study on Noise Reduction of an Air Conditioner through Modification of Axial Flow Fans and Shrouds)

  • 김창준;윤홍열;정용규;박영민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.380-387
    • /
    • 2000
  • In this paper, a successful result of modification of an axial flow fan and a shroud for noise reduction of a window type air conditioner is presented especially in order to verify the importance of blade shape improvement and the searching for the optimal shape of shrouds. Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have special shapes. From the viewpoint of the shape in a shroud, several cases were examined and the particular value of a design parameter of the shroud was acquired to get the best noise reduction of an air conditioner. Through the application of the methods, the air conditioner became less noisy by 4.5 dB(A) in terms of air-borne noise produced only by the axial flow fan and consumed less energy by 20.9% compared to the current one.

  • PDF