• 제목/요약/키워드: Air Conditioner

검색결과 776건 처리시간 0.023초

학교건물에서 냉방부하에 따른 열적 쾌적성 평가지표 비교 연구 (A Study on the Comparison of Thermal Comport Performance Indices for Cooling Loads in the Classroom)

  • 노광철;오명도
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1274-1279
    • /
    • 2004
  • We performed the numerical study on the comparison of thermal comport performance indices for cooling loads in the classroom when the 4-way cassette air-conditioner is mounted on the ceiling. We investigated the velocity and the temperature distribution of the classroom as with respect to the variation of the air diffusion angle of the air-conditioner. Air diffusion performance index and Predicted mean vote were used for analyzing the characteristics of the thermal comport in the classroom and comparing their values each other. From the numerical results, we knew that the thermal comport is largely affected by the air diffusion angle and velocity of the air-conditioner. And we also found out that the qualitative tendency of the distribution between Air diffusion performance index and Predicted mean vote is very similar in all occupied zone.

  • PDF

퍼지 알고리즘을 이용한 시스템 에어컨의 냉매충전량 감지 프로그램 개발 (Program Development for Detecting Charged Refrigerant Amount in System Air-Conditioner using Fuzzy Algorithm)

  • 태상진;최창식;김훈모;조금남;문제명;김종엽;권형진
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.172-179
    • /
    • 2006
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in the system air-conditioner than in a general single air-conditioner. Experiments were performed for a 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The experimental amount of the charged refrigerant was ranged from $60\%\;to\;140\%\;with\;10\%$ increasement. Fuzzy algorithm was employed for detecting the charged refrigerant amount in the system air-conditioner. The experimental data were used for curve-fitting for the general ranges of indoor and outdoor temperature conditions. Membership function was determined for the whole ranges of experimentally measured data and rule-bases were defined for each charged refrigerant amount. Developed program successfully predicted the measured data within $10\%$ resolution range.

실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발 (Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment)

  • 이수영;;태상진;윤백
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.

중형공간에서 중앙공조방식과 시스템에어컨 방식에 따른 PMV와 $CO_2$농도, 에너지소비량 비교 (Comparison of the PMV and $CO_2$ Concentration, Energy Consumption Characteristics of Central Air-Conditioning System and System Air-Conditioner with Ventilation System for Large Space)

  • 성상철;노광철;진심원;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.298-303
    • /
    • 2008
  • PMV, $CO_2$ and the energy consumption performance were numerically investigated in a large space with air-conditioning systems of four type. The numerical results showed that thermal comforts in the occupied zone are nearly similar in three systems except 3-way wall type system air-conditioner with ventilation system installed 2.2m height from the bottom. In case of 3-way wall type system air-conditioner the energy consumption for cooling loads was reduced about 25.5% compared to other air-conditioning systems. From the viewpoint of IAQ, it was turned out that system air-conditioner with ventilation system became worse about 20% compared to central air-conditioning systems for cooling load. The PMV, $CO_2$ concentration and energy consumption of all systems for heating loads were similar in a large space considered.

  • PDF

벽걸이에어컨의 원심홴에 대한 과도진동 규명 및 저감 (Transient Vibration Identification and Reduction of a Centrifugal Fan for a Wall-installed Air-conditioner)

  • 김민성;임종혁;정진태
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.383-390
    • /
    • 2016
  • In this paper, experiment and dynamics simulations were carried out to identify and reduce the out-of-plane vibration that occurs in a centrifugal fan of an air conditioner installed to a wall. In a wall-installed air conditioner, large space between a case and heat exchanger is often required for the fan to avoid the collision with the case and exchanger. This large space hinders the slim design of the air conditioner even if air conditioner market demands a slim air conditioner. In the present study, in order to determine the cause of the vibration in the centrifugal fan, the out-of-plane vibration and the physical properties were investigated, and the dynamic characteristics of the centrifugal fan were obtained by experiments. Based on these experiments, a dynamic simulation model was established to determine the cause of the out-of-plane vibration of the centrifugal fan. It was found that the main factor of out-of-plane vibration in the centrifugal fan is the axial misalignment between the centrifugal fan and the motor shaft.

저소음 패키지형 공기조화기의 실내기 개발에 관한 연구 (Study on the Development for Low Noise Indoor Unit Package Air-Conditioner)

  • 이재효;조성철;김태헌
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.518-523
    • /
    • 2003
  • The purpose of this study was to reduce the noise emitted from the package air-conditioner. The optimum design methods of the fans ware investigated experimentally through the analysis of noise problem caused by the conventional PAC system. New PAC system had decreased 6 dBA in overall noise level as compared with the conventional system by various technology.

Experimental Study of Performance Characteristics of Various Fin Types for Fin-Tube Heat Exchanger

  • Youn, Baek;Kim, Young-Saeng;Park, Hwan-Young;Park, Hyun-Yeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.29-38
    • /
    • 2000
  • Air side heat transfer and pressure drop for f 9.52 fin-tube heat exchanger with various types of slit and louver fins were measured, and compared with wave-slit fin. Longitudinal and transverse tube spacings of the heat exchangers are 21.65 mm and 25mm respectively. Actual heat exchanger was tested using water, and the tests were performed for 2 row heat exchangers with 3 different fin spacings, 1.3, 1.5 and 1.7 mm. The overall performance of the enhanced fins was evaluated by comparing heat transfer coefficient with respect to fan power

  • PDF

천장형에어컨 기류가 화재감지기 작동에 미치는 영향 분석 (Study on Influence of Air Flow of Ceiling Type Air Conditioner on Fire Detector Response)

  • 최문수;이근오
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.40-45
    • /
    • 2018
  • 이 논문은 천장형 에어컨의 기류가 화재감지기 작동에 미치는 영향을 분석한 연구이다. 천장형 에어컨의 기류를 형성시킨 가운데 화재감지기의 작동특성을 분석하기 위하여 ISO표준에서 규정한 방법으로 화재실험을 수행하였다. 실험은 10 m (가로) ${\times}$ 7 m (세로) ${\times}$ 4 m (높이) 크기의 화재실험장에서 수행하였다. 실험에 사용된 화재감지기는아날로그식 열감지기와 아날로그 연기감지기이다. 화원으로는 열감지기 작동을 위해 n-heptane을 사용하였고, 연기 감지기 작동을 위해 면심지(Cotton)를 사용하였다. 실험 결과, 화재감지기의 응답은 기류가 없을 때는 화원으로부터 거리가 멀어질수록 늦어지는 패턴을 보이나, 강한 기류에서는 그 패턴이 유지되지 못한 것을 확인하였다. 천장형 에어컨 기류가 없는 경우에 비해 기류가 강한 경우에 응답시간이 연기감지기는 121%, 열감지기는 39% 늦어졌다. 천장형 에어컨이 설치된 장소에서는 화재감지기 개수를 늘려 풍구 4방향에 모두 설치하거나 감도가 뛰어난 감지기를 설치하는 것이 화재의 조기감지를 위해 필요할 것으로 판단된다.

축류팬 및 슈라우드 개선을 통한 공조기 저소음화에 대한 연구 (Study on Noise Reduction of an Air Conditioner through Modification of Axial Flow Fans and Shrouds)

  • 김창준;윤홍열;정용규;박영민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.380-387
    • /
    • 2000
  • In this paper, a successful result of modification of an axial flow fan and a shroud for noise reduction of a window type air conditioner is presented especially in order to verify the importance of blade shape improvement and the searching for the optimal shape of shrouds. Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have special shapes. From the viewpoint of the shape in a shroud, several cases were examined and the particular value of a design parameter of the shroud was acquired to get the best noise reduction of an air conditioner. Through the application of the methods, the air conditioner became less noisy by 4.5 dB(A) in terms of air-borne noise produced only by the axial flow fan and consumed less energy by 20.9% compared to the current one.

  • PDF

통신기지국용 하이브리드 냉방기의 성능특성 연구 (Performance Characteristics of a Hybrid Air-Conditioner for Telecommunication Equipment Rooms)

  • 김용찬;최종민;강훈;윤준상;김영배;최광민;이호성
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.874-880
    • /
    • 2006
  • The power density and heat dissipation rate per unit area of the telecommunication equipment have been increased with the technology development in the footprint of telecommunication hardware. A proper heat dissipation method from the PCB module is very important to allow reliable operation of its electronic component. In this study, a hybrid air-conditioner for the telecommunication equipment room was designed to save energy and obtain system reliability. For high outdoor temperatures, the hybrid system operates in the vapor compression cycle, while, for low outdoor temperatures, the hybrid system works in the secondary fluid cooling cycle with no operation of the compressor. The performance of the hybrid air-conditioner was measured by varying outdoor and indoor temperatures. The hybrid air-conditioner yielded 50% energy saving compared with the conventional refrigeration system when the mode switch temperature was $8.3^{\circ}C$.