• 제목/요약/키워드: Air Condition

검색결과 4,333건 처리시간 0.039초

Influence of curing condition and carbonation on electrical resistivity of concrete

  • Yoon, In-Seok;Hong, Seongwon;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제15권6호
    • /
    • pp.973-987
    • /
    • 2015
  • The electrical resistivity of air-dried, saturated, and carbonated concretes with different mixture proportions was monitored to evaluate and quantify the influence of the age of the specimen, carbonation, and curing condition. After 28 days of curing, four prepared specimens were stored in a vacuum chamber with 5% $CO_2$ for 330 days to make carbonated specimens. Four of the specimens were placed in water, and four specimens were cured in air until the end of the experiments. It was observed that the electrical resistivity of the carbonated specimens increased as carbonation progressed due to the decrease of porosity and the increase of hydrated products. Therefore, in order to estimate the durability of concrete, its carbonation depth was used as the measurement of electrical resistivity. Moreover, an increase of electrical resistivity for air-dried and saturated concretes was observed as a function of age of the specimen. From the relationship between chloride diffusivity provided by Yoon et al. (2007) and the measurements of electrical resistivity, it is expected that the results well be of significant use in calibrating chloride diffusivity based on regular measurements of electrical resistivity during concrete construction.

건축재료로부터 방출되는 라돈방사능 감소를 위한 흑탄과 활성탄 효과 (Effect of Black Charcoal and Activated Carbon for Reduction of Radon Radioactivity that Emitted from Building Materials)

  • 조윤민;이화형
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.13-17
    • /
    • 2011
  • Recently, interest in indoor air quality is increasing. Especially, radon radioactivity among the indoor air is a well-known risk factor for lung cancer because of ionizing radiation in the form of ${\alpha}$-particles. This study was carried out to investigate effect of black charcoal and activated carbon for reduction of radon radiation that emitted from building materials. Black charcoal and activated carbon were used as a barrier which was against the infiltration of radon. The source of radon was gypsum board. Two types of charcoal barrier were powder- and board-type with 5 mm, 10 mm thickness respectively. The method for this determination is evaluated radon concentration in chamber. The measurements were performed with radon detector, SARAD3120. Results of this study are as following: Black charcoal and activated carbon confirmed the highly efficient barrier. Radon concentration was reduced from 72% to 85% as compared the control chamber. Radon reduction capability, however, was no difference as barrier's types. Results obtained in ventilation condition, radon concentration shows 5.93 pCi/L on average in the closed condition and shows 2.69 pCi/L in the opened condition.

  • PDF

전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구 (An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province)

  • 이태강;최은석;김항;김형렬;기노갑;김선우
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

서울지역 미세먼지 고농도에 따른 천식사망자 사례일의 종관기상학적 분류 (Synoptic Meteorological Classification of the Days on Which Asthma Deaths Occurred Due to High PM10 Concentrations in Seoul)

  • 최윤정;박종길;정우식
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.159-172
    • /
    • 2017
  • Asthma deaths in Seoul peaked on the third, fifth, and second days after the PM concentration exceeded the daily average concentration standard. We classified the synoptic meteorological conditions, based on the days involving such cases, into three categories. Type 1 included the meteorological condition likely to cause high air pollution concentrations in the leeward region, the dominant wind direction of which is the northwest. Type 2 included the meteorological condition likely to cause high air pollution concentrations due to the weak wind velocity under stable atmospheric conditions. Type 3 was when the passage low atmospheric pressure and the expansion of high atmospheric pressure occurred at the rear, indicating a meteorological condition likely to cause high air pollution, in certain regions. Type 1 occurred 11 times, with high concentrations of over $100{\mu}g/m^3$ being observed in the southeastern part of Seoul. Type 2 occurred 24 times, often accompanied by a PM concentration of $100{\sim}400{\mu}g/m^3$. Type 3 occurred 11 times, and was accompanied by several days of yellow dust that accounted for the highest concentrations.

일부 학교급식소 조리실의 위생관리에 관한 조사연구 (A Survey on the Sanitary Condition of Kitchens in School Food-service Programs)

  • 김종규
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.87-93
    • /
    • 2003
  • A survey including an inspection was conducted to assess the sanitary condition of kitchens in the school food-service programs and to prepare background data for improving the safety of school meals. The survey was carried out over a two-month period (September-October, 2001). A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools in one region of Korea about food, sanitation, and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during preparation, cooking, and service. The inspection results showed their sanitary rendition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4~22.4$^{\circ}C$. and the range of relative humidity was 62.4~69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22..5 to 26.5 CFU/15 minutes. Although the results of inspection show that the levels of sanitary condition of kitchens in the schools were good, they are not satisfactory for safe food-servile because the temperature and humidity levels are high. This study indicates that the school kitchens should be monitored and strict inspection is necessary. The legal standards for school food-service should include standards for kitchen air temperature, relative humidity, and airborne microbes.

Fatigue Crack Growth Characteristics of the Pressure Vessel Steel SA 508 Cl. 3 in Various Environments

  • Lee, S. G.;Kim, I. S.;Park, Y. S.;Kim, J. W.;Park, C. Y.
    • Nuclear Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.526-538
    • /
    • 2001
  • Fatigue tests in air and in room temperature water were performed to obtain comparable data and stable crack measuring conditions. In air environment, fatigue crack growth rate was increased with increasing temperature due to an increase in crack tip oxidation rate. In room temperature water, the fatigue crack growth rate was faster than in air and crack path varied on loading conditions. In simulated light water reactor (LWR) conditions, there was little environmental effect on the fatigue crack growth rate (FCGR) at low dissolved oxygen or at high loading frequency conditions. While the FCGR was enhanced at high oxygen condition, and the enhancement of crack growth rate increased as loading frequency decreased to a critical value. In fractography, environmentally assisted cracks, such as semi-cleavage and secondary intergranular crack, were found near sulfide inclusions only at high dissolved oxygen and low loading frequency condition. The high crack growth rate was related to environmentally assisted crack. These results indicated that environmentally assisted crack could be formed by the Electrochemical effect in specific loading condition.

  • PDF

램제트 엔진의 지상시험용 Vitiated Air Heater의 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of the Vitiated Air Heater in the Ramjet Engine Ground-Testing)

  • 윤현진;손창현;이충원
    • 한국추진공학회지
    • /
    • 제3권4호
    • /
    • pp.51-57
    • /
    • 1999
  • Ramjet 엔진에서 Ramjet 입구의 초음속 유동에 의한 압축과정은 연소기내로 유입되는 공기의 온도를 상승시킨다. 따라서 고도와 비행조건에 따라 변하는 실제비행조건을 모사하기 위해서는 공기의 온도와 속도를 정확하게 제어할 필요가 있다. 본 연구에서는 Vitiated Air Heater를 제작하여 공기, 수소, 산소의 안을 변화시키면서 Vitiated Air Heater 연소가스(Vitiated Air)의 온도분포와 속도분포, 그리고 연소가스 성분을 측정함으로써 Vitiated Air Heater의 성능을 평가하였다. 그 결과 Ramjet 엔진의 지상실험범위에 요구되는 Ramjet 연소기 입구의 유입 속도범위(80~120 ㎧)와 온도범위(400~800 K)를 만족하였으며, 균일한 속도 및 온도분포로 대기공기와 같은 산소성분비를 가지는 Vitiated hir를 얻을 수 있었다.

  • PDF

Fe계 합금 분말 소결품(SMF9060)의 마모 특성 연구 (A Study on Tribological Characteristics of Powder Sintered Fe-base Alloy (SMF9060))

  • 김상윤;김대욱;박영민;신동철;김태규
    • 열처리공학회지
    • /
    • 제27권2호
    • /
    • pp.65-71
    • /
    • 2014
  • SMF9060 material is a Fe-based powder sintered alloy that is used for several automobile components such as Synchronize Hub, oil pump and transmission. These components are required excellent wear resistance and durability. In this study, we have performed a dry wear test at the ambient air and Ar gas conditions in the room temperature, and a lubricant wear test at the room temperature and engine oil temperature of $100^{\circ}C$. The amount of wear volume and coefficient friction are measured by a Profilometer and a Ball on disk type wear tester. The wear volume in Ar gas condition was a little higher than that in the ambient air condition. However the wear volume in the lubricant wear condition was much lower than in the dry wear condition. XRD analysis of the debris in Ar gas condition showed that the oxide film was not formed.

교육시설물의 실내공기질 측정 및 개선방안에 관한 연구 (A study on the Measurement and Improving Method of Indoor Air Quality in a Educational Facility)

  • 김성겸;김재온;조창연;김종록;손재호
    • 교육시설
    • /
    • 제14권4호
    • /
    • pp.43-52
    • /
    • 2007
  • People spend more than 90% of their time indoor. Nowadays as they are interested in environment much more than before, indoor air pollution has been regarded as new environmental problems. At present, an air quality check is required prior to the completion of construction. However this study shows that the density level of HCHO and VOCs in a classroom was increased after furnishing the classroom. Thus, to measure the quality of air more effectively and accurately, it should be measured after the indoor space are furnished. Newly-built schools are tested for this study. The building sites were investigated to measure and evaluate the IAQ (Indoor Air Quality) in newly-built schools. The result of this study can be used as a basis to improve the environment air condition of the educational facilities.

표면부착형 영구자석 전동기의 정현파 공극자속밀도 연구 (A Study on Sinewave Air Gap Flux Density of Surface Type Magnet Motor)

  • 김현철;김장목;김철우
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1571-1576
    • /
    • 2007
  • This report describes the analytical characteristic of sinewave air gap flux density for the brushless AC motor with surface permanent magnet. The analysis of sinewave air gap flux density is the key to expect the performance of back EMF for the design of brushless AC motor. The numerical analysis and FEM analysis are performed to adopt radial and parallel flux magnetization of magnet on the rotor. And it is also executed to vary the magnet arc angle and arc radius for the condition of constant and non constant air gap. This report is focused on the characteristic of sinewave air gap flux density for permanent magnet of surface brushless AC motor. This results also have more reliable data against the previous paper which had the representative numerical analysis of air gap flux density[1][2].