• Title/Summary/Keyword: Air Condition

Search Result 4,333, Processing Time 0.033 seconds

A Preliminary Study of Low Temperature Condition by Heat Exchanger (열교환기를 이용한 저온 환경 구축에 대한 기초 연구)

  • Lee, Yang-Suk;Yang, Jae-Joon;Kim, Yoo;Ko, Young-Sung;Lim, Byeung-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.23-26
    • /
    • 2007
  • A preliminary, study of low temperature condition was performed to simulate high altitude condition. The mixed air temperature were investigated at various condition by experiments using cryogenic air by heat exchanger and normal temperature air. An experimental setup was constructed to simulate low temperature condition with liquid nitrogen. To control mass flow rate, orifice and pressure regulators were used. The experimental results show that the mixed air temperature increases linearly with mass flow rate of normal temperature air. Therefore it can be help to simulate a low temperature condition of high altitude.

  • PDF

An investigation of air condition in Cheong Ju & Je Cheon City Area (청주.제천시지역 대기실태 조사)

  • 김재용;김창영
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.19-28
    • /
    • 2002
  • We concluded to analysis the air condition of city area in the Chungbuk province by pollutant concentration and weather survey data to used from the data of Air Pollution Monitoring System until September in 2002 from 1998. The results of this study is to prove out the pollutional phenomena and effects in the each area of Cheong-ju & Je-cheon city and to provide the basic data of comfortable environmental condition in the province. Also, we provide environmental statistical dat for the inhabitants in the province as the present condition analysis of air pollution. We got the conclusion of having air condition as clear state in Chungbuk Province from our analytical results.

Frost Formation on a Cylinder under Heat Pump Condition (히트펌프 조건의 원형관에서의 착상에 관한 연구)

  • Yoon, Shin-Hyuk;Cho, Keum-Nam;Hayase, Gaku
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.804-809
    • /
    • 2009
  • The present study measured frost pattern on a cylinder to propose empirical correlation equations for the local and average frost thickness, frost density and frost mass. The key parameters were diameter of the cylinders (7mm, 20mm), cooling surface temperature of the circular tube, absolute humidity of air, air temperature and air velocity. A 50% ethylene glycol aqueous solution was applied as a coolant. The frost thicknesses at both front and rear were larger than those at the other parts, while they were increased as diameter of the cylinder was increased. The local frost thicknesses at high air velocity were more uniform than those at low air velocity. The values predicted by Kim et al. under the freezer condition showed larger by the maximum of $30{\sim}50%$ than the measured data under heat pump condition. The empirical correlations for the local and average frost thickness and frost mass were proposed. The correlation equations for the frost thickness and frost mass under the heat pump condition in the present study might predict more accurate than the other correlation equations. The proposed correlations might be applied for the freezer condition within the maximum 15% deviation from the previous correlations under freezer condition.

  • PDF

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

Noise Prediction of Train Using Ray Tracing Method and Statistical Energy Analysis (음선추적법과 통계적 에너지 분석법을 이용한 철도차량 실내 소음 해석)

  • Park, Hee-Jun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.942-946
    • /
    • 2010
  • As the major sources of interior noise of train at running condition are the wheel/rail contact noise, the traction motor's noise and the driving gear's noise and these noise sources are transmitted through the car body, the noises of HVAC and air duct can be ignored. But the interior noise of train at standstill condition is decided by HVAC's noise and noise from the diffuser through the air duct. the interior noise prediction of train at standstill condition should be performed considering the shape of air duct, the air velocity and noise reduction property inside the air duct. But it is hard to estimate the interior noise level by the numerical method. Therefore train maker predict the interior noise level using The commercial noise prediction program. This paper introduce the noise prediction method of the train at standstill condition using the commercial program appling the ray tracing method and statistical energy analysis.

  • PDF

A Study on the Management Plan of Water Environment of Ferns in the Interior Landscape (실내조경에 있어서 양치식물의 수분환경 관리방안에 관한 연구)

  • 주진희;방광자;설종호
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.1
    • /
    • pp.122-131
    • /
    • 1999
  • Indoor environments are usually less than optimal for the growth of ferns, especially in regards to the water condition. These studies were performed to investigate responses involved in causing growth of ferns and presume management plan against the water deficit under indoor conditions. The effect of air humidity and soil moisture on the ferns was examined in Adiantume raddianum and Selaginella kraussiana. Results of experiments are as follows; 1. Under a low humidity condition, having a 25-50% RH. ornamental value of ferns decreased much more than under a 90% RH. Under a low soil moisture, such as sand treatment, ornamental value of ferns also decreased. 2. Leaf chlorophyll content, water content and stomata situations increased as air humidity and soil moisture went up. 3. Even if air humidity and soil water were not enough for ferns growth, the extending of irrigation cycle was helpful. 4. Under extremely low air humidity conditions, some water management, namely, using water holding soil or extending of irrigation cycle was desirable. Other methods of increasing air humidity, including water instruments such as ornamental pools, waterfalls, or fountains, grouping plants together were also helpful. But spraying water on leaves increased injury to ferns growth because of excess evaporation from the leaves. Though these studies, we learn that ferns are susceptible to water condition such as air humidity, soil water and water management. If other environmental factos are maintained with optimal conditions, water condition plays an important role in ferns growth in indoor environments.

  • PDF

Optimization of monitoring methods for air-borne bacteria in the environmental conditions of pig facilities (무균 돈사 환경 모니터링을 위한 대기 중 미생물 탐지기법 확립)

  • Lee, Deok-Yong;Seo, Yeon-Soo;Kang, Sang-Gyun;Yoo, Han Sang
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.3
    • /
    • pp.255-261
    • /
    • 2006
  • Experimental animals have been used to biological and medical purposes and the animals must be, for these purposes, healthy and clean to microbial infection. However, the animals can be easily exposed to pathogenic microorganism via several routes. Of the routes, environmental conditions are the most important factors to keep the animals healthy and clean, especially air condition. Monitoring of air-condition has been required to keep the animal healthy and clean. However, any guideline is not available for experimental conditions with pigs. Therefore, the sampling times and points were compared in different conditions to establish an optimal protocol for monitoring of air borne bacteria. Tryptic soy agar(TSA), blood agar containing 5% defibrinated sheep blood and Sabraud dextrose agar(SDA) were used as media to capture total bacteria, pathogenic bacteria and fungi, respectively. Two methods, compulsive capture using an air-sampler and capturing fall-down bacteria were used to capture the microorganisms in the air. The points and time of capturing were different at each experiment. Air borne microorganisms were captured at three and five points in the open and closed equipments, respectively. Air was collected using an air-sampler for 1 min and 5 min and the agar plates as open status were left from 30 min to 2hr. At first, we monitored an experimental laboratory which dealt with several pathogenic bacteria and then, a protocol obtained from the investigation was applied to open or close experimental conditions with pigs. Number of bacteria was high from 10:00 to 15:00, especially on 13:30-15:30 but sharply decreased after 17:00. The tendency of the number of bacteria was similar between two methods even though the absolute number was higher with air sampler. Critical difference in the number of cells was observed at 5 min with air sampler and 2 hr with fall-down capturing method. However, 1 min with air sampler and 1 hr with fall-down capturing were the best condition to identify bacterial species collected from the air. Number of bacteria were different depending on the sampling points in closed condition but not in opened condition. Based on our results, a guide-line was suggested for screening air-borne microorganism in the experimental conditions with pigs.

ENVIROMENTAL CONDITION DURING AIR SHIPMENT OF HORTICULTURAL PRODUCTS FROM OKINAWA TO TOKYO

  • Akinaga, Takayoshi;Kohda, Yoshihiro
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.413-422
    • /
    • 1993
  • Air shipment affords the quickest possible delivery of horticultural products. The price of air shipped horticultural products are relatively high as most of these products are perishable. Usually the temperature in the cargo compartment is not controlled during flight. Thus, special attention should be paid to procooling prior to shipment. The environmental condition during transportation of horticultural products is an essential parameter for maintaining the quality of perishable products. Commonly horticultural products were loaded by ULD(Unit Load Devices) as a container or pallet in the aircraft (except for small aircraft) . Therefore, inside temperature of the container and cargo compartment came into question. Scarce literature on the relationship between environmental condition and quality changes of horticultural products during air shipment can be found. By the stand point of keeping fresh quality, investigations on the actual condition of air shipments were carried out to improve the technique during the distribution process of fresh horticultural products. Temperature, humidity, atmospheric pressure, carbon dioxide, ethylene, impacts, and changes in quality during the air shipment of snapbeans, okras and chrysanthemums were measured. Temperature was measured by recording thermometers, relative humidity by recording hygrometers, atmospheric pressure by a strain -guage type pressure sensor, carbon dioxide by testing tubes, ethylene by sampling bags and a gaschromatograph, impacts and vibrations by impact recorders and a 3D accelerometer. Relationships between environmental conditions and quality changes during air shipments were clarified. It was expected from investigations into actual shipments that the ventilation and insulation properties of air freight containers were related to the quality of agricultural products. Aircraft can no directly load and unload trucks into them. The transshipment is inclined to cause shocks and vibrations, and to invite damages within a short time.

  • PDF

Psychological and Physiological Responses of Occupants Caused by Types of Seat Air Conditioning (좌석시트 공조조건에 따른 착석자의 심리 및 생리적 반응)

  • Kim, Boseong;Kwak, Seung Hyun;Seo, Sang Hyeok;Min, Byung Chan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.14-20
    • /
    • 2015
  • It is important to understand psychological and physiological responses of occupants who seated in a chair in order to shape a comfortable indoor official environment. So it is needed to find out optimal seated conditions. The purpose of this study was to explore optimal condition of seat air conditioning control based on psychological or subjective responses (perceived temperature and comfort sensation) and physiological responses (heartrate variability; HRV). To do this, experimental conditions were designed by the difference of indoor temperature and seat air conditioning temperature. In the experiment 1, seven experimental conditions were designed with one control condition which was not used seat air conditioning system, and six experimental conditions which the difference of indoor temperature and seat air conditioning temperature ($-1^{\circ}C{\sim}-6^{\circ}C$). In the experiment 2, four experimental conditions were designed with one control condition and three experimental conditions ($-3^{\circ}C{\sim}-5^{\circ}C$). In addition, participants' psychological or subjective response was measured by CSV (comfort sensation vote) and PTS (perceived temperature sensitivity) as a psychological or subjective response, and heartrate variability was measured as a physiological response. As a result, in the experiment 1, it was reported that the optimal conditions of seat air conditioning control based on participants' psychological or subjective comfort were from $-3^{\circ}C$ to $-5^{\circ}C$ experimental conditions. In addition, in the experiment 2, it was reported that the optimal condition of seat air conditioning control based on participants' physiological comfort was $-4^{\circ}C$ experimental condition. These results suggested that seat air conditioning could affected to comfort sensation of occupants in an appropriate range, rather than unconditionally.

A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition

  • Song, Doo-Sam;Kang, Ki-Nam;Park, Dong-Ryul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.137-146
    • /
    • 2007
  • CFD simulation is a very useful tool to predict the concentration of contaminant generated from the building materials in a single room. However, there is a limitation on analyzing air movement and contaminant concentration in a multi-room when the door of each room is closed. In this study, network based simulation was coupled with contaminant simulation for the multi-room condition, using an network simulation tool 'ESP-r'. The coupled simulation was first validated with experimental measurements which performed to define the characteristics of the analyzed space prior to the simulation, and indoor air flow and contaminant concentration between rooms were then analyzed when the door of each room was open and closed in the case of natural and forced ventilation.