• 제목/요약/키워드: Air Compressor Design

검색결과 318건 처리시간 0.02초

전동 스크롤압축기의 운전rpm에 따른 냉동사이클의 성능에 대한 실험적 연구 (Experimental Study on the Performance of Refrigeration Cycle for various RPM of Inverter Scroll Compressor)

  • 이규선;이근안;이형욱;이영선;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.42-48
    • /
    • 2014
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle with inverter scroll compressor. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDy to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. This study revealed that the condenser temperature and pressure were increased and the evaporator temperature and pressure were decreased with the increased compressor speed. And also, the COP was decreased with increased compressor speed. Those results can be used the basic and fundamental data to design the air-conditioning cycle with inverter scroll compressor.

분리형 인버터 에어컨의 운전조건에 따른 성능 연구 (A study on the performance of a split system inverter air-conditioner at different operation conditions)

  • 김만회
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

벤치 연비 모사 조건에서 차량용 에어컨 압축기의 특성에 관한 연구 (Study on Characteristics of Car Air-con Compressor Under Bench System Fuel Economy Simulation Condition)

  • 유성연;김영신
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.705-710
    • /
    • 2012
  • 본 연구에서는, 차량용 에어컨 시스템으로 구성된 벤치 장비에서의 실험을 통하여 에어컨 관련 북미 실차 연비 평가 모드 중의 하나인 SC03 모드 연비 평가의 벤치 모사 시험 가능성을 검증하였다.본 연구에 사용된 설비는 차량용 에어컨 시스템을 실차 조건처럼 구성할 수 있는 각각의 챔버로 구분되어져 있으며, 외부 환경을 재연할 수 있도록 온도와 습도, 풍속을 제어할 수 있도록 구성하였다. 지금까지 실차 환경 풍동에서 평가 되어지던 SC03 모드 연비 평가에 대하여 시스템 벤치에서 모사가 가능하도록 실차에서 가장 중요한 변수인 차속과 차량 전면 풍속에 대응하는 압축기 회전수와 응축기 전면풍속에 대한 신뢰성을 확보하였다.이를 바탕으로 다양한 토출 용량을 가지는 압축기를 가지고 에어컨 시스템 벤치 장비에서 SC03 연비 모사 실험을 수행하여, 압축기 토출량의 차이에 따른 연비의 차이가 특징 지어지는 것을 확인하였다.

Robust Design of Air Compressor-Driving Quadratic Linear Actuator in Fuel Cell BOP System using Taguchi Method

  • Kim, Jae-Hee;Kim, Jun-Hyung;Kim, Jin-Ho
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.275-279
    • /
    • 2012
  • The linear actuator has the inherent drawback of air gap variation because its linear motion is usually guided by the springs, which destabilizes the dynamic performance. In order to design the linear actuator to be insensitive to air gap, this paper describes the robust design of the air compressor driving linear actuator using Taguchi method. The orthogonal arrays are constructed with selected control factors and noise factor for minimum experiment. The control factors are thickness of inner magnet, height of upper yoke, thickness of outer magnet and thickness of lower yoke while noise factor is airgap. The finite element analysis using commercial electromagnetic analysis program "MAXWELL" are performed instead of experiment. ANOVA are performed to investigate the effects of design factors. In result, the optimal robust linear actuator which is insensitive to air gap variation is designed.

진동 특성 파악을 통한 인버터 에어컨의 운전 주파수 및 파이프 형상 결정 (Determination of the Operating Frequency and Pipe Design of Inverter Air-conditioner considering Dynamic Characteristics of Inverter Rotary Compressor)

  • 모진용;이진교;박득용;김진섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.203-206
    • /
    • 2001
  • The reduction of chopping noise generated from inverter compressor and the piping design reducing vibration are the most important items in the quality of air conditioner. The chopping noise is identified by the study of the relationship between carrier frequency and natural frequency of the compressor shell. The high carrier frequency is the key factor in reduction of carrier noise. To keep the natural frequencies of the system as far as away from the operating frequencies appears to be the most important factor in the design of piping system.

  • PDF

HFC-134a용 원심압축기의 성능시험 및 설계방안 (The Design and Performance Test of a Centrifugal Compressor for HFC-134a Refrigerant)

  • 신정관;김경훈;강신형
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.139-148
    • /
    • 2010
  • A centrifugal compressor for HFC-134a has been newly designed and developed. Flow analysis using commercial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. The purpose of this study is to establish the design theory necessary to the development of HFC-134a centrifugal compressors and to supply basic data related to design by reviewing design values and experimental values through the performance test. The compressor for HFC-134a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-134a centrifugal compressors.

차량용 에어컨 압축기가 실차 연비에 미치는 영향에 관한 실험적 연구 (Experimental Study on Effects of Compressor for Automotive Air Conditioning System on Fuel Economy)

  • 유성연;김영신
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.59-65
    • /
    • 2013
  • 본 논문은 차량용 에어컨 압축기가 실차 연비에 미치는 영향에 대하여 실험적으로 연구한 것으로, 본 연구의 목적은 연비에 주요한 영향 인자인 압축기의 토출 용량별 구동 토크에 의한 실차 연비 기여도를 분석하는 것이다. 연비에 직접적인 영향을 주는 압축기의 부하를 측정하기 위하여 압축기 클러치에 직접 부착하는 토크 센서를 개발하였으며, 실차 평가전 벤치 토크 미터와의 비교 평가를 통하여 토크 센서의 신뢰성을 검증하였다. 토크 센서가 부착된 압축기를 장착한 차량을 환경 풍동에서 연비 측정을 할 수 있도록 장치를 구성한 상태에서 연비 평가를 수행하였다. 압축기의 토출 용량에 따른 구동 토크는 연비에 직접적인 영향을 주며, 동일 사양 압축기에서 토출 용량이 약 11% 커질 때 연비는 약 2~3% 악화됨을 알 수 있었다.

웨이브 와셔 스프링의 강성치에 관한 연구 (A Study on the Stiffness of Wave Washer Spring)

  • 이수종;왕지석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권3호
    • /
    • pp.74-81
    • /
    • 1996
  • The wave washer springs are widely used in non-return valves of fluid, especially in air check valves to confirm the rapid shut-off of valve propers. The stiffness of wave washer springs used in suction and exhaust valves of reciprocating air compressor play an important role on efficiency of the compressor. If the stiffness of the spring is too high, the pressure differences necessary to open the valves become high and the volumetric efficiency of cylinder decreasse. If the stiffness of the spring too low, the valve can not be closed rapidly and the inverse flow of air can take place. So, the optimum stiffness of valve spring is very important and it will be very helpful that the stiffness of wave washer springs to be used in suction and exhaust valves can be calculated in design stage of air compressor. In this paper the formula for calculating the spring constant of wave washer spring is introduced using bending and torsion theory of frames. The experiments are also carried out to measure the spring constants of several samples. It is proven that the calculated spring constants of wave washer springs are coincided well with measured values and that the formula presented in this paper for calculating the spring constants of wave washer spring is very useful for design of valves used in reciprocating air compressor.

  • PDF

스크류 압축기의 연구개발 동향 (Research Trend in Screw Compressor Development)

  • 이대영;김영일;남임우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.151-158
    • /
    • 1998
  • The screw compressor is first invented by a Swedish engineer, Alf Lysholm in 1934. Since then, the development of the screw compressor idea for industrial applications has been continued by the Swedish research organization Svenska Rotor Maskiner, often identified by its initials SRM. The first industrial application of the machine was marketed as an air compressor in the 1950s. The screw compressor which is a positive displacement type compressor compresses gases by the rotation of a pair of mating rotors. The operation of this compressor is entirely rotary and dynamically in balance. Also there is no need for any valve mechanism and there exists less mechanical wear between the parts compared to the conventional reciprocating compressors. Due to these prominent features, the screw compressor has been rapidly spread into the air compressor market replacing the conventional reciprocating compressors and begun to be applied as a refrigerant compressor since the 1960s. In this work, the operation principle of the screw compressor is described in brief and the major design parameters affecting the compressor performance are classified. The international research trend in screw compressor development is introduced and the current situation in our country is described.

  • PDF

에너지 절약을 위한 다수 에어컴퓨레셔 자동제어장치 설계 (Design of Multiple-Air-Compressor Automatic Controller for Energy Savings)

  • 양성규;김갑순
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.53-59
    • /
    • 2020
  • This paper describes the design of a remote control device that can control the ON/OFF state of multiple air compressors using wireless communication. The main remote controller and air compressor remote controller were designed using a microprocessor (ATmega128), and the circuit diagram was configured to wirelessly communicate using A Zigbee module between the two remote controllers. The result of the measurement of wireless communication distance between the two remote controllers was more than 1.1 km.