• 제목/요약/키워드: Air Compression System

검색결과 259건 처리시간 0.023초

오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석 (Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

$CO_2$ 2단 트윈 로타리 압축기 성능해석 (Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

통계적 에너지 해석 기법에 의한 공조용 로타리 압축기의 소음 진동 전달 경로 해석 (A Study on the Noise and Vibration Transmission Path of Rolling Pistion Type Rotary Compressor Using SEA)

  • Hwang, Seon-Woong;Jeong, Hyeon-Chul;Ahn, Byung-Ha;Jeong, Weui-bong;Kim, Kyu-Hwan
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.385.2-385
    • /
    • 2002
  • Hermetic rotary compressor is one of the most important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify sources of noise and vibration and effectively control them. (omitted)

  • PDF

가역 화학 열 펌프(CHP)를 이용한 냉장.냉동 시스템 개발 연구 (R&D OF FREEZING AND REFRIGERATION SYSTEM USING CHP.)

  • 이종호;김석종
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.132-135
    • /
    • 1996
  • This study is to develop an ammonia based chemical heat pump(STELF) for a freezing and refrigeration system coupled to gas, fuel and/or waste from industrial processes as heat sources. Recently it has been continually taking a growing interest in chemical heat pumps without electric power and having higher COP's than those of existing compression type refrigeration systems using freon. By introducing STELF technology, efficient heat recovery utilizing enormous amount of waste heat in energy consuming large scale industries or building for their own refrigeration purposes is possible. Moreover, air-conditioning systems coupled to city gas for small scale industries or building can be realized. Therefore, STELF technology can contribute much for overall energy savings and efficient energy management.

  • PDF

SEA에 의한 회전 압축기의 소음 진동 해석 (Noise and Vibration Analysis of Rotary Compressor by SEA)

  • 황선웅;안병하;정의봉;김규환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2003
  • Hermetic rotary compressor is one of the most Important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of He system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration. it is necessary to identify sources of noise and vibration and effectively control then. Many approaches have been tried to identify noise sources of compressor. However, compressor noise source identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this work, Statistical Energy Analysis has been used to trace the energy flow in the compressor and identify transmission paths from the noise source to the sound field.

  • PDF

액-가스 열교환기를 이용한 R170(에탄)용 냉동시스템의 성능 특성 (Performance Characteristics of Refrigerant R170(Ethane) Refrigeration System Using Liquid-gas Heat Exchanger)

  • 구학근
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.78-85
    • /
    • 2016
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system using R170. These liquid-gas heat exchangers(internal or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. Exception for the effect of inner diameter, the RCI of R170 with respect to refrigerant mass flowrate, the length and effectiveness of internal heat exchanger is about 2.1~3.3% higher than that of R13 at the same experimental conditions. With a thorough grasp of these effect, it is necessary to design the R170 compression refrigeration cycle using internal heat exchanger.

발파작업 시 충전매질에 따른 발파효과 비교 연구 (A Comparative Study on the Effect of Tamping Materials on the Impact Efficiency at Blasting Work)

  • 배상수;한우진;장승엽;방명석
    • 한국지반신소재학회논문집
    • /
    • 제21권2호
    • /
    • pp.57-65
    • /
    • 2022
  • 본 연구에서는 폭약과 발파공 사이의 충전매질을 통한 충격파 전파 효과를 수치적으로 시뮬레이션하고 검증하였다. 고체(Lagrangian)와 유체(Eulerian)를 혼합 모델링하기 위해 Arbitrary Lagrangian-Eulerian(ALE) 방법을 선택하였다. 시간의존적 해석은 발파공정 시간 동안 수행되었다. 폭약과 매질(공기 또는 물)을 유한 요소망으로 모델링하였고, 발파공은 시작점(폭약)에서 발파공벽에 도달하는 전파 속도와 충격력을 결정할 수 있는 강체로 가정하였다. 해석결과에 따르면 물의 전파속도와 충격력은 공기의 경우보다 컸다. 추가로 발파 작업의 실제 현장을 모델링하고 시뮬레이션하였다. 암석은 탄소성체로 가정하였다. 해석결과에 따르면 충전매질이 물인 경우 순간 충격력이 더 크고, 파쇄블록 크기는 더 작은 것으로 나타났다. 반면 발파공배면에서의 충격량은 물인 경우에 더 작았는데, 이는 파쇄에 충격에너지가 상당부분 사용되고, 파쇄로 인한 감쇠 효과에 의해 주변의 고체를 통한 압력 전파는 공기보다 작아지기 때문이다. 이로써 충전매질로서 물이 공기보다 경제성이 더 높다는 것이 입증되었다.

마하 2.5 초음속 공기흡입구의 버즈 특성에 관한 연구 (Study on the Buzz Characteristics of Supersonic Air Intake at Mach 2.5)

  • 이형진;정인석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.331-335
    • /
    • 2006
  • 초음속 흡입구는 안정한 유동은 설계점에서 얻을 수 있지만, 비행 중 나타나는 비설계점에서는 흔히 버즈라고 불리는 공력 불안정성에 직면하게 된다. 버즈가 일어나는 동안, 흡입구는 흡입구 선단에 큰 충격파 진동이 나타나며 그에 따라 후류에는 압력 섭동이 발생하며 이는 엔진의 성능감소를 야기한다. 본 연구는 버즈의 일반적인 특성을 파악하기 위해 1단 꺽임각을 갖는 외부 압축식 축대칭 흡입구를 이용하여 실험적, 수치적 연구가 수행되었다. 본 연구를 통해 간헐적으로 나타나는 버즈를 관찰할 수 있었고 배압이 증가할수록 버즈가 일어나는 주파수가 커짐을 확인할 수 있었다.

  • PDF

저온 플라즈마 처리한 폴리에스테르 직물의 키토산 처리에 따른 물리화학적 특성변화 -KES평가를 중심으로- (Physicochemical Characterization of PET Fabrics Treated with Chitosan after Exposure to $O_2$ Low Temperature Plasma - Especially by KES evaluation -)

  • 구강;김삼수;박영미;유재영;구본식;유승춘
    • 한국염색가공학회지
    • /
    • 제17권5호
    • /
    • pp.26-36
    • /
    • 2005
  • This study was carried to evaluate mechanical characteristics of Poly(ethylene terephthalate) fabrics (by Kawabata evaluation system(KES)) which was systematically treated with $O_2$ low temperature plasma and chitosan acetate solution. Furthermore, surface structure was investigated by SEM, AFM, air permeability and wettability. Tensile energy(WT), shear rigidity(G) and surface roughness(MIU) properties calculated by KES-FB have increased with increasing plasma treatment time, while bending rigidity(G) and energy of compression(WC) value were decreased compared with those of the untreated. SEM photographs showed the identification of chitosan coating but did not confirm the plasma etching structure. Air permeability was decreased according to plasma treatment time with increasing concentrations of chitosan. The water absorption rate made rapid progress by chitosan treatment.