• 제목/요약/키워드: Air Column

검색결과 360건 처리시간 0.037초

역타기둥 이음부의 공기포 배출을 위한 실험적 연구 (The Experimental Study on Deflation of Air for Top-Down Joint area)

  • 임형일;이동하;백민수;박병근;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.763-768
    • /
    • 2001
  • The purpose of this study is to research a specific material characteristics of top down concrete at column joint and to reduce column joint opening. Based on the established top down study, the experiment to apply an real construction case is performed. When the concrete placed into joint of top down column, raised air bubble is left as opening. This study is examined the incomplete packing reason in the top down column and found to air deflation method. The result of study is below (1) As the method to minimize column opening caused from confined air, it is required that an air exhaust port installation in joint column. (2) From air exhaust port installation, most of air bubble in column part is exhausted. As the concrete placing height is going up, air bubble size is going smaller.

  • PDF

고정식 진동수주형 파력발전기에 관한 실험적 연구 (A Study for Fixed Type Wave Energy Conversion Device with Oscillating Water Column)

  • 김성근;박노식;박인규
    • 한국해양공학회지
    • /
    • 제10권2호
    • /
    • pp.136-145
    • /
    • 1996
  • The theory is based on two thermodynamic equations for the air mass in the air column and bydrodynamic equation for the relation between the response of the air in the water column and the incident wave. The numerical model is experimented in a two dimensional water tank and the caisson model with sloped front wall is tested in the large towing tank.

  • PDF

3축 마이크로 공작기계용 자기예압 공기베어링 스테이지의 정, 동적 특성 (Static and Dynamic Characteristics of Magnetically Preloaded Air Bearing Stage for a 3-Axis Micro-Machine Tool)

  • 노승국;;;박종권
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.468-472
    • /
    • 2005
  • In this paper, the static and dynamic stiffness of the air bearing stage for micro-micro machine tool are examined experimentally. For stiffness and precision concerns, air bearing stages are adapted for 3-axis micro-milling machine which is size of $200x200\;mm^2$. The air bearings in the stage are preloaded by permanent magnets to achieve desired bearing clearance and stiffness for vertical direction. As the stiffness of the air bearing is primary interests, static stiffness test were performed on XY stage in Z direction and Z column in Y direction. Dynamic test were performed on XY stage and Z column, respectively. Both static and dynamic tests were performed in different air pressure conditions. The vertical stiffness of XY stage is about 9 N/ pm where Y stiffness of Z column is much smaller as $1\;N/{\mu}m$ because of the large moment generated by Y force on the column.

  • PDF

Zygosaccharomyces rouxii와 Candida versatilis의 동시 고정화에 의한 Air Bubble Column Reactor에서 간장의 연속적 속성 생산 (Continuous rapid Production of Soy Sauce by Coimmobilized Mixed Culture system of Zygosaccharomyces rouxii and Candida versatilis using Air Bubble Column Reactor)

  • 류병호
    • KSBB Journal
    • /
    • 제18권6호
    • /
    • pp.455-460
    • /
    • 2003
  • 간장의 속성 발효를 위한 방법으로 간장 발효에 간여하는 Z. rouxii BH-90과 C. versatilis BH-91 혼합 균체를 동시 고정화하여 이를 air bubble column reactor에 충진하여 국 고온 분해액을 주입하면서 연속적으로 발효를 시도하였다. 균체의 고정화 담체로는 실리카겔: 3% 알긴산소다 (1:1의 비율) 혼합액을 사용하여 Z. rouxii BH-90과 C. versatilis BH-91을 동시 고정화하여 air bubble column reactor에 충진하여 발효시킨 결과 발효 96시간 경과시 ethyl alcohol이 2.4% 생성되었으며 4-ethylguaiacol은 18mg/L가 생성되었다. Air bubble column reactor에서 Z. rouxii BH-90과 C. versatilis BH-91 혼합균체의 동시 고정화 beads의 연속적 속성 발효시 시작일로부터 30일까지는 ethyl alcohol이 2.5∼2.8%로 거의 일정하게 생성되었고, 40∼70일에는 약간 감소하였다. 그리고 동시 고정화 균체의 발효에서는 40일까지는 4-ethylguaiacol의 함량이 16∼18mg/L로 거의 일정하게 생성되었으나 발효 45일 이후 70일까지는 약간 감소하였다. 발효종료 후의 제품을 분석한 결과 동시 고정화 균체의 발효액에서는 2.4%의 ethyl alcohol이 생성되었고, 18mg/L의 4-ethylguaiacol이 생산되었다. 유리 아미노산의 함량은 glutamic acid, leucine, arginine, aspartic acid, Iysin 및 valine이 전체 아미노산의 50% 이상을 차지하고 있었다.

인두 이물감을 호소하는 환자에서 식도 내 공기에 대한 연구 (Esophageal Air in Patients with Globus Pharyngeus)

  • 심예지;남동우;김보해;진영주;유윤종;김민수;정은재;권성근;하정훈;권택균
    • 대한후두음성언어의학회지
    • /
    • 제26권2호
    • /
    • pp.127-129
    • /
    • 2015
  • Background and Objectives : The etiology of globus pharyngeus remains uncertain. It has been known there is a relationship between the presence of air bubbles in esophagus and GERD symptoms. The aim of this study is to identify relationship between the globus symptom and the presence of air column in esophagus. Subjects and Methods : The study population consisted of 46 patients who underwent CT scan as part of evaluation for globus. Controls were chosen from the population consisted of patients with lymphadenopathy who underwent CT scan. The correlation between the presence of globus symptom and diameter, volume, and position of the air column was assessed using t-test. Reproducibility of diameter and volume of the esophageal air column was analyzed using intraclass correlation coefficient. Results : In study group, the mean volume of the air column was $769.56{\pm}983.08mm^3$, the mean diameter was $8.24{\pm}4.90mm$, the mean distance from the inferior border of posterior lamina of cricoid cartilage was $88.86{\pm}28.01mm$. In control group, $682.18{\pm}767.28mm^3$, $8.37{\pm}5.50mm$, $88.34{\pm}21.06mm$, respectively. There were no differences of diameter, volume and distance of the air column between the two groups. We failed to obtain acceptable reliability when we compare the diameter and the volume of the esophageal air column. Conclusion : There was no relationship between air column of esophagus and presence of globus symptom. And the measurement of diameter and volume of the esophageal air column change over time and it should be considered in a further study.

  • PDF

Experimental Study on Mass Transfer Rate at the Packed Column of Solar Cooling Liquid Desiccant System Using Counter Flow Configuration

  • Hengki R, R.;Choi, K.H.;Yohana, Eflita;Sukmaji, I.C.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.155-161
    • /
    • 2009
  • Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling the latent load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed column and the heat transfer and mass transfer will occur. This proposal is try study the mass transfer and heat transfer inside the packed column of dehumidifier and regenerator systems. And later on, the rates of dehumidification and regeneration that were affected by desiccant flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems.

  • PDF

심랭식공기분리공정에서 질소증류탑의 엑서지 해석 (Exergy Analysis of Nitrogen Distillation Column in the Cryogenic Air Separation Process)

  • 용평순;이성철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.145-150
    • /
    • 2002
  • The distillation column is one of large energy consumable units in the cryogenic air separation process and the accurate energy analysis of this unit is necessary for choice of energy saving process. In this work, the energy method was adopted for energy analysis of a cryogenic nitrogen distillation column. In order to designing the energy saving distillation column, the exergy distribution of feed air, exergy efficiency and exergy loss for process condition was investigated and the optimal process condition to minimize the exergy loss was found. The result from this work can be used as a guideline for the choice of the process design conditions and efficiency improvement of cryogenic distillation column.

가변 수주진동장치를 이용한 고효율 파력발전에 관한 연구 (Studies on Variable Liquid-Column Oscillator for High Efficiency Floating Wave Energy Conversion System)

  • 양동순;조병학
    • 한국해양공학회지
    • /
    • 제23권5호
    • /
    • pp.15-24
    • /
    • 2009
  • The results of a simulation study of variable liquid column oscillations in U-tanks with a novel control scheme are presented. The configuration under investigation is analogous to that of the tuned liquid-column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. However, by virtue of an adequate controller, the response of amplitude of the U-tanks becomes larger in a desired frequency range. The motion of wave energy conversion system equipped with a variable liquid column oscillator is described by a series of nonlinear differential equations. The equations describe the motion of body under ocean wave excitation, and the motion of liquid with an air-spring effect caused by the compression and expansion of air in vertical liquid columns and air chambers. It is shown that the effect of the air-spring has a vital role to maintain the natural frequency of oscillation in the system to synchronize with the frequency of the ocean wave, thus the system provides the most effective mode for energy extraction from the ocean.

계면촬성제 첨가에 따른 지하수 폭기법의 폭기효율 변화 연구 (Surfactant Aided Air-sparging for Groundwater Remediation)

  • 소효은;최경민;이승재;김헌기
    • 자원환경지질
    • /
    • 제35권5호
    • /
    • pp.421-428
    • /
    • 2002
  • 계면활성제를 사용하여 지하수의 표면장력을 인위적으로 감소하였을 때, 감소된 표면장력이 지하수 폭기시의 폭기 영향권 및 VOC 제거 효율에 미치는 영향을 실험실 규모의 실험을 통하여 규명하였다. 내경 9.5 cm, 길이 100 cm의 유리 컬럼에 계면활성제(sodium dodecyl sulfate, SDS) 및 toluene 100 ppm 포함하는 물로 채운 후 일정한 속도로 공기를 주입하였을 때의 toluene의 제거 속도를 측정하였다. 또한 같은 컬럼에 토양(모래)이 채워진 상태에서 동일한 실험을 반복하였다. 토양이 존재하지 않는 상태에서의 stripping에 의한 toluene의 제거 속도는 표면장력의 감소(계면 활성제 농도의 증가)에 따라 증가하는 것으로 나타났으며, 토양이 존재하는 경우에도 비슷한 결과를 나타내었다. 2차원 유리 상자에 모래와 SBS를 포함하는 물을 채운 후 일정한 공기 유속을 유지하였을 때, 폭기의 영향권(공기의 침투영역)은 물의 표면장력 감소에 따라 현저히 증가하는 것으로 나타났다. 특히 SDS의 critical micelle concentration(CMC)보다 훨씬 낮은 농도에서 폭기 영향권이 최대화하는 것으로 밝혀졌다. 본 연구결과는 폭기에 의한 지하수 오염물질 중, 특히 휘발성 유기오염물질의 제거 공정의 효율을 증대하는데 기여할 것으로 생각된다.

GENERATION OF p-DINITROBENZENE ATMOSPHERE AND METHEMOGLOBIN FORMATION IN RATS

  • Kim, Young-Chul
    • Toxicological Research
    • /
    • 제5권2호
    • /
    • pp.97-104
    • /
    • 1989
  • A new exposure system was developed to generate p-dinitrobenzene (p-DNB) containing atmosphere. A glass column was filled with small glass beads coated with the chemical. The p-DNB containing medium was heated to a temperature beyond the boiling point of p-DNB. A stream of air flow was forced to pass through the column and let it mixed with fresh air before introducing into an inhalation chamber. The concentration of p-DNB in the chamber air was measured by direct assaying the air directly and by sampling the chemical using a microfilter installed in the chamber.

  • PDF