• Title/Summary/Keyword: Air Chemistry

Search Result 986, Processing Time 0.032 seconds

Indoor exposure to hazardous air pollutants and volatile organic compounds in low-income houses in Lagos, Nigeria

  • Luqmon, Azeez;Musa, Olaogun;Mariam, Adeoye;Abdulazeez, Lawal;Babatunde, Agbaogun;Ibrahim, Abdulsalami;Adija, Majolagbe
    • Advances in environmental research
    • /
    • v.1 no.4
    • /
    • pp.277-288
    • /
    • 2012
  • This study investigated exposure to air pollutants in rooms in low-income houses at Shomolu (R1), Mafoluku (R2) and Mushin (R3) in Lagos state. The concentrations of most measured exceeded limits of Illinois Department of Public Health (IDPH) for indoor air quality. Air quality index (AQI) in rooms studied was unhealthy for sensitive people in terms of CO, unhealthy in terms of $SO_2$ and very unhealthy in terms of $NO_2$ while moderate air quality was obtained in terms of $PM_{10}$ in most rooms. High concentrations of carbontetrachloride, formaldehyde and xylene measured could have been responsible for some of the health complaints of the occupants. Factor analysis shows that cooking with kerosene, use of gasoline generator and insecticide were the major contributors to indoor air pollution in these rooms. Therefore, there is need to urgently tackle poverty as all affected by these pollutants were poor who live in substandard houses without kitchens.

The Stable Rechargeability of Secondary Zn-Air Batteries: Is It Possible to Recharge a Zn-Air Battery?

  • Lee, Sang-Heon;Jeong, Yong-Joo;Lim, Si-Hyoun;Lee, Eun-Ah;Yi, Cheol-Woo;Kim, Keon
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.1
    • /
    • pp.45-49
    • /
    • 2010
  • The rechargeable Zn-air battery is considered as one of the potential candidates for the next generation secondary batteries due to its many advantages. However, its further applications and commercialization have been limited by the complexity of the reactions on air electrode which are oxygen reduction and evolution reactions (ORR/OER) upon discharging and charging processes, respectively. In the present study, lanthanum was impregnated into a commercial Pt/C gas diffusion electrode, and it clearly verified significantly enhanced cycling stability and reversibility. The results presented in this study show the possibility of repeated charge/discharge processes for Zn-air batteries with a La-loaded air electrode, and they demonstrate the potential as a promising next generation secondary battery.

Numerical Characteristics of Hypersonic Air Chemistry and Application of Partially Implicit Time Integration Method (극초음속 공기반응의 수치해석적 특성과 부분 내재적 적분법 적용)

  • Kim, Seong-Lyong;Ok, Ho-Nam;Ra, Seung-Ho;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.1-8
    • /
    • 2003
  • Numerical characteristics of air chemistry associated with hypersonic flows are described and are compared with those of hydrogen oxygen combustion, applying the partially implicit time integration method to air chemistry. This paper reveals that the time integration of air chemistry needs a chemical Jacobian for stable calculations. However the positive real eigenvalues in air chemistry are relatively smaller than those of hydrogen combustion, and the numerical integration is less sensitive than that with combustion. lt is also found that the application of the partia1ly irnplicit method reduces the computing time without numerical instabilities.

Variation of TSP Compositions in Accordance with the Pathways of Inflowing Air Mass at Jeju Island (제주지역 TSP의 기류 유입경로별 조성 변화)

  • Ko, Hee-Jung;Kim, Won-Hyung;Lee, Min-Young;Song, Jung-Min;Kang, Chang-Hee;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.347-357
    • /
    • 2011
  • The TSP aerosols were collected at Gosan site of Jeju Island between 2003 and 2007, and their aerosol components were analyzed to examine the variations of chemical compositions with the corresponding pathways of inflowing air parcels. According to the comparison of seasonal aerosol compositions, the soil-originated components showed remarkably high concentrations during spring season. On the other hand, the concentrations of anthropogenic components were somewhat high in spring and summer seasons, but low in fall season. Based on the comparison of TSP compositions in relation to the pathways of inflowing air mass, the concentrations of anthropogenic components (nss-$SO_4^{2-}$, S, $NO_3^-$), soil-originated components (nss-$Ca^{2+}$, Al, Fe, Ca), and the heavy metals (e,g., Mn, Zn, Cr, Pb, Cu, Cd, etc.) have relatively increased with the air mass moving from China continent into Jeju area. Meanwhile, the marine-originated components showed an increasing trend with the air mass coming from North Pacific Ocean. In the seasonal and sectional comparison, the nss-$SO_4^{2-}$, $NO_3^-$, nss-$Ca^{2+}$, and Al showed comparatively high concentrations when the air mass moved from China continent during all seasons. Especially, the $NO_3^-$, nss-$Ca^{2+}$, and Al concentrations were somewhat high when the air mass moved from Korean Peninsula during summer season. It was also recognized that the Na+ concentration were high, when the air mass moved from Pacific Ocean through all seasons.

Effect of Carbon Dioxide in the Air on Zinc-air Cell (대기중의 이산화탄소가 공기-아연전지에 미치는 영향)

  • Kim, Nam-In;Park, Ki-Hong;Choi, Yong-Kook;Lee, Woo-Tae
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.177-182
    • /
    • 1999
  • The electrolyte was brought into contact with air and potassium carbonate concentration was measured with various contact time in order to check the effect of carbon dioxide in the air on zinc-air cell. The relationship between potassium carbonate concentration in electrolyte and battery capacity was also studied. The potassium carbonate concentration increased due to carbon dioxide absorption with increasing contact time with air, but the cell capacity linearly decreased with increasing potassium carbonate concentration in the electrolyte. The rate of carbon dioxide absorption was mainly affected by the pore size of hydrophobic membrane. Our study showed that adapting the pore of hydrophobic membrane decreased the loss of cell discharge performance due to the presence of carbon dioxide or water vapor in the atmosphere.

  • PDF

Synthesis and Characterizations of Mn1+XCo2-XO4 Solid Solution Catalysts for Highly Efficient Li/Air Secondary Battery (고효율의 리튬/공기 이차전지 공기전극용 Mn1+XCo2-XO4 고용체 촉매 합성 및 분석)

  • Park, Inyeong;Jang, Jaeyong;Lim, Dongwook;Kim, Taewoo;Shim, Sang Eun;Park, Seok Hoon;Baeck, Sung-Hyeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.4
    • /
    • pp.137-142
    • /
    • 2015
  • $Mn_{1+X}Co_{2-X}O_4$ solid solutions with various Mn/Co ratios were synthesized by a combustion method, and used as cathode catalysts for lithium/air secondary battery. Their electrochemical and physicochemical properties were investigated. The morphology was examined by transmission electron microscopy (TEM), and the crystallinity was confirmed by X-ray diffraction (XRD) analyses. For the measurement of electrochemical properties, charge and discharge measurements were carried out at a constant current density of $0.2mA/cm^2$, monitoring the voltage change. Electrochemical impedance spectroscopy (EIS) analyses were also employed to examine the change in charge transfer resistance during charge-discharge process. $Mn_{1+X}Co_{2-X}O_4$ solid solutions showed enhanced cycleability as a cathode of Li/air secondary battery, and the performance was found to be strongly dependent on Mn/Co ratio. Among synthesized catalysts, $Mn_{1.5}Co_{1.5}O_4$ exhibited the best performance and cycleability, due to high charge transfer rate.

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

An Effective Process for Removing Organic Compounds from Oily Sludge

  • Jing, Guolin;Luan, Mingming;Chen, Tingting;Han, Chunjie
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.5
    • /
    • pp.842-845
    • /
    • 2011
  • Wet air oxidation (WAO) of oily sludge was carried out using $Fe^{3+}$ as catalyst, placed in a 0.5 L batch autoclave in the temperature range of $250-330^{\circ}C$. Experiments were conducted to investigate the effects of temperature, the initial COD, reaction time, concentration of catalyst and $O_2$ excess (OE) on the oxidation of the oily sludge. The results showed that in the WAO 88.4% COD was achieved after 9 min reaction at temperature of $330^{\circ}C$, OE of 0.8 and the initial COD of 20000 mg/L. Temperature was found to have a significant impact on the oxidation of oily sludge. Adding a catalyst significantly improved the COD removal. Homogenous catalyst, $Fe^{3+}$, showed effective removal for pollutants. COD removal was 99.7% in the catalytic wet air oxidation (CWAO) over $Fe^{3+}$ catalyst. The results proved that the CWAO was an effective pretreatment method for the oily sludge.