• 제목/요약/키워드: Air Bar

검색결과 324건 처리시간 0.021초

Experimental and Analytical Study on the Bus Duct System for the Prediction of Temperature Variations Due To the Fluctuation of Load

  • Thirumurugaveerakumar, S.;Sakthivel, M.;Valarmathi, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2036-2041
    • /
    • 2014
  • In this paper, a thermal model is developed for the bus bar system to predict the temperature variation during the transient time period and to calculate both the steady-state and transient electrical current carrying capacity (ampacity) of bus bar. The bus bar system installed in the power house of Kumaraguru College of Technology, Coimbatore has been considered. Temperature variation predicted in the modelling is validated by observing the current and steady state temperatures in different feeders of the bus bar. Magnetic field of the extreme phases R and B induces more current in the middle phase Y. Hence, the steady state temperature in the phase Y is greater than other two phases. The transient capabilities of the bus bar are illustrated by calculating the variations in the bus bar temperature when it is subjected to a step change in current during the peak hours due to increase in hostel utilities and facilities (5.30 pm to 10.30 pm). The physical and geometrical properties of the bus bar and temperature variation in the bus bar are used to estimate the thermal time constants for common bus bar cross-sections. An analytical expression for the time constant of the bus bar is derived.

운동 분석을 통한 욕창 방지용 침대 기구의 개선 (Improvement of the Medical Bed for Preventing Decubitus Ulcer through Motion Analysis)

  • 심창섭;심재경;권진욱;임득재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.713-718
    • /
    • 2003
  • Decubitus ulcer is a pressure-induced ulceration of the skin occurring in persons confined to bed for long periods of time. In order to prevent decubitus ulcer, the medical bed mechanism to minimize pressure, friction, and shear forces acting between bed and patient had been developed. Air mattress also can be effective for reducing pressure over bony prominence. In this study, motion analysis was performed to examine whether this bed mechanism functioned properly in case of using air mattress, which was much thicker than common hospital mattress. We found that the patient on the air mattress above the medical bed for preventing decubitus ulcer slipped upward and downward excessively as the general motored-bed. New bed mechanisms were synthesized kinematically using simple 4-bar and 6-bar linkages so as to reduce sliding between the bed and the patient on the air mattress for preventing decubitus ulcer.

  • PDF

흡입공기온도와 분무압력이 분쇄땅콩의 유동층 코팅효율에 미치는 영향 (Effect of Inlet Air Temperature and Atomizing Pressure on Fluidized Bed Coating Efficiency of Broken Peanut)

  • 강현아;신명곤
    • 한국식품과학회지
    • /
    • 제34권5호
    • /
    • pp.924-926
    • /
    • 2002
  • 분쇄땅콩의 결착력 증대 및 산패방지를 위한 유동층코팅 기술을 개발하고자, 유동충코팅공정의 흡입공기온도 및 분무압력이 분쇄땅콩의 유동층 코팅효율에 미치는 영향을 검토하였다. 흡입공기온도가 높을수록 코팅효율이 증가하였으며, 분무압력도 3 bar까지는 분무압력이 커질수록 코팅효율이 증가하는 경향을 나타내었다. 그리고, 덱스트린과 카제인나트륨로 구성된 코팅물질은 분쇄땅콩의 산패를 부분적으로 억제할 수 있음을 보여주었다.

연료전지용 공기공급기의 케이스 변형량 해석 및 개선설계 (Deformation Analysis and Design Modification of the case of the air blower for fuel cell)

  • 제우성
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.43-48
    • /
    • 2011
  • The air blowers for fuel cell electric vehicle usually have big difference between inlet and outlet pressure. When the casing of the air blowers is designed, the stress analysis is required. (Approximately Inlet pressure is 0.5bar and outlet pressure is 2bar.) Gap distance between the casing and the impeller is 0.3mm. Therefore, if the amount of maximum deformation of casing is larger than 0.3mm, impeller crashed the casing. In order to avoid crashing, both the thickness and number of rims are changed and carried out simulations on each cases.

CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측 (Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD)

  • 손정은;유병호;방승기;이광호
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

자속 측정을 통한 유도전동기의 회전자 바 손상 검출기법 (Detecting Method for Broken Rotor Bar of Induction Motors by Flux Measurement)

  • 황돈하;한상보;강동식;김병국;김미정;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.827-828
    • /
    • 2006
  • This paper proposes a new method for detecting broken rotor bars in a squirrel-cage induction motor. The air-gap flux variation analysis was done using search coils inserted in stator slots when broken rotor bar occurs. An accurate modeling and analysis of air-gap flux variation in the induction motor are developed using finite-element(FE) software packages, and measurement of the flux are made using search coils. The simulation was done for the induction motor with 380 [V]. 7.5 [kW], 4 Poles, 1,760 [rpm] ratings using the commercial FE analysis tool. The simulation and experiment results can be useful for detecting the broken rotor bar of an induction motor.

  • PDF

$NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구 (The Study on Performance Characteristics of Superheating the Suction Vapor in $NH_3$ Refrigeration System)

  • 권일욱;하옥남
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.756-761
    • /
    • 2004
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the NH$_3$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 14.5 bar to 16.0 bar by 0.5 bar and for superheat temperature from $0^{\circ}C$ to 1$0^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

A Method for Indentifying Broken Rotor Bar and Stator Winding Fault in a Low-voltage Squirrel-cage Induction Motor Using Radial Flux Sensor

  • Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.666-670
    • /
    • 2011
  • In this paper, a method for detecting broken rotor bar and stator winding fault in a low voltage squirrel-case induction motor using an air-gap flux variation analysis is proposed to develop a simple and low cost diagnosis technique. To measure the leakage flux in radial direction, a radial flux sensor is designed as a search coil and installed between stator slots. The proposed method is able to identify two kinds of motor faults by calculating load condition of motors and monitoring abnormal signals those are related with motor faults. Experimental results obtained on 7.5kW three-phase squirrel-cage induction motors are discussed to verify the performance of the proposed method.

선삭가공용 CAM 시스템의 개발에 관한 연구 (A study on the development of CAM system for turning)

  • 양민양;이성찬;최종률;강성균
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.529-533
    • /
    • 1996
  • Recently, manufacturing industries are doing their best to increase productivity and to reduce production time. One of tile efforts is to develop user-friendly and effective CAM systems. For this purpose, a CAM system for turning was developed. In the developed system. user interacts with tile CAM system using graphical user interface (GUI) and manufacturing support functions to make NC programs effectively. Manufacturing support functions include cycle decoder. interference check be ween tool and workpicce. bar turning without air cut and dynamic/wireframe simulation. In the cycle decoder. basic options are provided to novices for their convenience. and advanced options are provided to help expert to modify the program using their knowledge. Interference check has been nil issue in tile CAM system for tuning. In this paper. when a user selects a tool. interference check between selected tools and workpieces is done automatically. Moreover. remaining shapes are calculated automatically. Then, tile CAM system requests user to input all additional tool and generates NC codes to cut tile remaining shapes. In bar turning of forged raw material, air cut should be prevented for effective machining. For this purpose, a new algorithm for bar turning was developed. Dynamic and wireframe simulation was used to verify the generated NC code.

  • PDF

전극형상 및 보이드에 따른 XLPE의 부분방전 특성 (Partial Discharge Characteristics of XLPE According to Electrode Shape and Void)

  • 신종열;김균식;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.50-57
    • /
    • 2016
  • Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of $16{\times}40{\times}30$ [mm] was used as negative electrode. In order to investigate the PD with ${\phi}$-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.