• Title/Summary/Keyword: Aged degradation

Search Result 186, Processing Time 0.408 seconds

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

A Consideration of Degradation Mechanism of a Effect of the Nitric Solution on the Aging Characteristics of the Outdoor Silicone Rubber (열화 메커니즘 규명을 위한 옥외용 실리콘고무의 산성비 성분 열화특성 연구)

  • Lee, J.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.132-136
    • /
    • 2002
  • In this paper, aging characteristics of outdoor silicone rubber insulator resulting from the acid rain have been investigated with regards to nitrate ion $({NO_{3}}^{-1})$. For this purpose, silicone rubber was aged by immersing into the nitric solutions with different level pH during 1500 hours and various tests (tracking, $tan{\delta}$, breakdown voltage, SEM, EDS, contact angle) were performed. It was observed that the degradation was increased to pH 2.5 slightly and at pH 1.5 highly. And thus, it could be expected that there is certain critical point between pH 1.5 and 2.5, which leads to throught degradation.

  • PDF

Evaluation of the Ductile-Brittle Transition Behavior of fracture Toughness by Material Degradation (열화에 따른 파괴인성치의 연성-취성 천이거동 평가)

  • 석창성;김형익;김상필
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.140-147
    • /
    • 2003
  • As the huge energy transfer systems like as nuclear power plant and steam power plant are operated for a long time at a high temperature, mechanical properties are changed and ductile-brittle transition temperature is raised by degradation. So it is required to estimate degradation in order to assess the safety, remaining life and further operation parameters. The sub-sized specimen test method using surveillance specimen was developed for evaluating the integrity of metallic components. In this study, we would like to present the evaluation technique of the ductile-brittle transition temperature by the sub-sized specimen test. The four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. The tensile test and fracture toughness test were performed. The results of the fracture toughness tests using the sub-sized specimens were compared with the evaluation technique of the ductile-brittle transition temperature.

Retardation of Degradation in Accelerated Aging of Cotton Cellulose Using Borohydride Reduction

  • Kim, Hye-Kyung;Choi, Hyung-Min
    • International Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • Degradation of cellulose during prolonged exposure in atmospheric conditions has been recognized as one of main problems in preserving cellulose-made products. The purpose of this research was therefore to study effects of borohydride reduction in improving both the color and strength retention of cotton fabrics artificially aged at temperatures ranging from $100^{\circ}C$ to $150^{\circ}C$. Results indicated that the fabrics treated with either sodium or tetramethylammonium borohydrides (TMA) were degraded at rates about one-half that of water-washed cotton. These results were consistent over the temperature range. Calculation of the activation energy (Ea) by different methods showed $Ea\;=\;25.5{\pm}\;1.5\;Kcal$, in keeping with measurements made by others at lower temperatures. The TMA-treatment was effective in minimizing discoloration of the fabrics with pre-baking, but not of the un-prebaked fabrics.

Low Cycle Fatigue Characteristics of Duplex Stainless Steel with Degradation under Pure Torsional Load (순수 비틀림 하중하에서 열화를 고려한 2상 스데인리스강의 저주기 피로특성)

  • Gwon, Jae-Do;Park, Jung-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1897-1904
    • /
    • 2002
  • Monotonic torsional and pure torsional low cycle fatigue(LCF) test with artificial degradation were performed on duplex stainless steel(CF8M). CF8M is used in pipes and valves in nuclear reactor coolant system. It was aged at 430$^{\circ}C$ for 3600hrs. Through the monotonic and LCF test, it is found that mechanical properties(i.e., yield strength, strain hardening exponent, strength coefficient etc.) increase and fatigue life(N$\sub$f/) decreases with degradation of material. The relationship between shear strain amplitude(${\gamma}$$\sub$a/)and N$\sub$f/ was proposed.

The Evaluation of Ductile-Brittle Transition of Fracture Toughness by Material Degradation (재료열화에 따른 파괴인성치의 연성-취성 천이거동 평가)

  • Kim, Sang-Pil;Kim, Hyung-Ick;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.579-584
    • /
    • 2001
  • As the huge energy transfer systems like as nuclear power plant and steam power plant are operated for a long time, mechanical properties are changed and ductile-brittle transition temperature is raised by degradation. So it is required to estimate degradation in order to assess the safety, remaining life, and further operation parameters. The sub-sized specimen test method using surveillance specimen was developed for evaluating the integrity of metallic components. In this study, we would like to present the evaluation technique of the ductile-brittle transition temperature by the sub-sired specimen test. The four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. The tensile test and fracture toughness test were performed. The results of the fracture toughness tests using the sub-sized specimens were compared with the evaluation technique of the ductile-brittle transition temperature.

  • PDF

Effect of $Ta_2O_5$ Alloying on Low Temperature Degradation of 3 mol% Y-TZP ($Ta_2O_5$ 첨가가 3 mol% Y-TZP의 저온열화에 미치는 영향)

  • 김대준;최두진
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.8
    • /
    • pp.630-638
    • /
    • 1992
  • Ta2O5 alloying into 3 mol% Y2O3-stabilized tetragonal ZrO2 polycrystals (3Y-TZP) increased the degradation during aging at 265℃ and the fracture toughness; both are determined by the amount of transformed m-ZrO2. It was proposed that the mechanism underlying the t→m transformation when aged at low temperatures is attributed to the reorientation of (Zzr'V ). complexes parallel to [111] lattice direction, which is accompanied by a relaxation of TZP lattice during annealing at low temperature. A small strain which results from the reorientation gives rise to a localized mechanical instability, thus lowering the nucleation barrier so that the t→m phase transformation (degradation) proceeds. The amount of transformed m-ZrO2 during aging becomes greater as the chemical free energy change related to the transformation, ΔGo, increases with increasing the Ta2O5 alloying content.

  • PDF

Prediction of Poisson's ratio degradation in hygrothermal aged and cracked [θm/90n]s composite laminates

  • Khodjet-Kesb, M.;Adda bedia, E.A.;Benkhedda, A.;Boukert, B.
    • Steel and Composite Structures
    • /
    • v.21 no.1
    • /
    • pp.57-72
    • /
    • 2016
  • The Poisson ratio reduction of symmetric hygrothermal aged $[{\theta}_m/90_n]_s$ composite laminates containing a transverse cracking in mid-layer is predicted by using a modified shear-lag model. Good agreement is obtained by comparing the prediction models and experimental data published by Joffe et al. (2001). The material properties of the composite are affected by the variation of temperature and transient moisture concentration distribution in desorption case, and are based on a micro-mechanical model of laminates. The transient and non-uniform moisture concentration distribution give rise to the transient Poisson ratio reduction. The obtained results represent well the dependence of the Poisson ratio degradation on the cracks density, fibre orientation angle of the outer layers and transient environmental conditions. Through the presented study, we hope to contribute to the understanding of the hygrothermal behaviour of cracked composite laminate.

Evaluation of Bond Strength of Isothermally Aged Plasma Sprayed Thermal Barrier Coating (플라즈마 용사 열차폐 코팅의 열화에 따른 접착강도 평가)

  • Kim, Dae-Jin;Lee, Dong-Hoon;Koo, Jae-Mean;Song, Sung-Jin;Seok, Chang-Sung;Kim, Mun-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.7
    • /
    • pp.569-575
    • /
    • 2008
  • In this study, disk type of thermal barrier coating system for gas turbine blade was isothermally aged in the furnace changing exposure time and temperature. For each aging condition, bond tests for three samples were conducted for evaluating degradation of adhesive or cohesive strength of thermal barrier coating system. For as-sprayed condition, the location of fracture in the bond test was in the middle of epoxy which have bond strength of 57 MPa. As specimens are degraded by thermal aging, bond strength gradually decreased and the location of failure was also changed from within top coat at the earlier stage of thermal aging to the interface between top coat and TGO at the later stage due to the delamination in the coating.

Small Punch Test for the Evaluation of Thermal Aging Embrittlement of CF8 Duplex Stainless Steel

  • Cheon, Jin-Sik;Kim, In-Sup;Jang, Jae-Gyoo;Kim, Joon-Gu
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.79-84
    • /
    • 1996
  • Small punch test was performed on CF8 duplex stainless steel aged at 370 and 400$^{\circ}C$ up to 5,000 h to evaluate the degree of the thermal aging embrittlement. At room temperature, the SP load-displacement curve was in a similar shape to those of ferritic steels and had a good reproducibility in spite of two-phase structure. The aging heat treatment resulted in a slight increase of the yield strength. As test temperature was lowered, the SP load showed a sudden drop followed by serrations before the SP specimen was fractured, resulting from the cracking of ferrite phase. The extent of thermal embrittlement was assessed in terms of the SP energy. Aging treatment at higher temperature led to a larger shift in the transition temperature and the corresponding change in the fracture mode. The main cause of the degradation was the embrittlement of ferrite phase. Additionally the phase boundary separation profoundly contributed to the degradation of the specimen aged at 400$^{\circ}C$.

  • PDF