• Title/Summary/Keyword: After-cooling

Search Result 1,291, Processing Time 0.03 seconds

The Effect of Isothermal Annealing on Microstructure of Forged Parts (단조품의 등온 어닐링에 따른 미세조직 변화)

  • Kim, D.B.;Lee, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.303-308
    • /
    • 2000
  • The ring gears of automobile parts are manufactured generally process chart of which is as follows : forging ${\rightarrow}$ annealing or normalizing ${\rightarrow}$ rough machining ${\rightarrow}$ hardening(Quenching-Tempering or carburizing process) ${\rightarrow}$ finish machining. Isothermal annealing process after forging is most effective in the side of improvment of machinability. On this study we selected two kinds of steel;SCM415, SCM435 of most universal and investigated microstructures to find out most suitable condition of heat treatment in proportion continuous cooling and isothermal annealing. As the cooling rate is $5^{\circ}C$ per minute in continuous cooling process, martensite and bainite are coexisted with ferrite and pearlite in SCM435 steel. If the cooling rate is slower than $5^{\circ}C$ per minute, microstructure were only ferrite and pearlite but formation of band structure can't be avoid. On the other hand, microstructure is only ferrite and pearlite regardless of cooling rate because carbon content of SCM415 steel is low. Moreover formation of band structure isn't exposed by faster cooling rate. Most optimal temperature of the isothermal annealing is from $650^{\circ}C$ to $680^{\circ}C$ in SCM435 steel. When holding time is 60 minute with $650^{\circ}C$, the identical ferrite and pearlite microstructures can be obtained.

  • PDF

A Study on the Development of the Console with LCD Panel for Exterior Advertizing (LCD 패널을 탑재한 옥외 광고용 콘솔 개발에 관한 연구)

  • Choi, Kab-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.13-20
    • /
    • 2010
  • The development of the console for exterior advertizing LCD Panel(LCD Console) is the purpose of this study with regard to importance of display industry. In this study, the most important point is to develop the cooling system for LCD Console. It is developed by using systematic application techniques and statistical tests and analysis to integrate commercial components, cooling fan, heat sink, thermo electronic modules etc, of it. This study, at first, shows design/manufacturing process of the cooling system and the setting process of control factors to control through experimentation. Next, after constructing the complete console, 46 inch LCD Panel and the cooling system are built in, the performance test of it is shown through experimentation.

Experimental Study of Showcase Using Cold Storage System (축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구)

  • Lee, Eun-Ji;Lee, Dong-Won;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1111-1116
    • /
    • 2008
  • The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.

  • PDF

Solar photovoltaic according to installation of cooling system (냉각시스템 설치에 따른 태양광 발전)

  • Hong, Seong-Goo;Choi, Hong-Kyoo;Yoo, Hai-Chool;Lee, Chan-Jae;Han, Sang-Kwon;Kim, Tae-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.189-192
    • /
    • 2008
  • The solar photovoltaic Power generator can get more power with the higher solar radiation quantity. However, if the higher solar radiation quantity on cell becomes high temperature, the efficiency of generate will be reduced. To install cooling system for this kind of device can be the way to solve high temperature problem on cell but another problems after install it such as increasing of solar generated quantity problem, cost to install cooling system and cost to be maintained cooling system weren't discussed to practical use this system. So the present paper described about effect and commercial business possibility of cooling system.

  • PDF

Variation of Antioxidant Retention and Some Properties of Soybean Oil during Simulated Frying Operations (반복(反復) 가열과정(加熱過程) 중의 일부 항산화제(抗酸化劑) 잔존량(殘存量) 및 대두유(大豆油) 성상(性狀)의 변화(變化))

  • Lee, Hyoung-Sub;Kim, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.86-92
    • /
    • 1979
  • Antioxidants. BHA, BHT and PG were added to a commercial soybean oil at a level of 200 ppm, and the antioxidant-treated oils and a control oil were subjected to 30 min. heating at $150{\pm}2^{\circ}C$ and 23.5 hr. cooling at room temperature for 6 times. Variations of % antioxidant retention and some physical and chemical properties of the oils were investigated. The results of the present study were as follows. 1. The % retention of BHA, BHT and PG after the second heating and cooling was respectively 60.5, 55.7 and 40.5 %. That of BHA, BHT and PG after the 6th heating and cooling was respectively 5.7, 3.0 and 1.8 %. 2. The refractive indices and viscosity of the oils, including the control, increased slowly at first. but after 4th heating and cooling, these values increased rapidly. The color indices of the oils, including the control, increased very rapidly, but after the 2nd heating and cooling, the rates of the increase diminished considerably. 3. The efficiency of each antioxidant in suppressing peroxide, thiobarbituric acid, and acid value development decreased rapidly as the antioxidant contents of the oils decreased. After the 6th heating and cooling, the peroxide. thiobarbituric acid and acid values of the oils treated initially with the antioxidants did not differ appreciably from those of the control.

  • PDF

Initial cooling conditions that extend the shelf-life of fresh oak mushrooms (Lentinula edodes) after harvest (신선 표고의 수확 후 유통수명 연장을 위한 예냉조건 구명)

  • Choi, Ji Weon;Lee, Ji Hyun;Kim, Chang-Kug;Park, Me Hea;Choi, Hyun jin;Lim, Sooyeon;Eum, Hyang Lan;Chang, Min-Sun;Hong, Yoon Pyo
    • Journal of Mushroom
    • /
    • v.20 no.3
    • /
    • pp.138-146
    • /
    • 2022
  • To optimize initial cooling conditions, forced-air cooling was applied to freshly harvested oak mushrooms at 2 levels (0℃ for 30 minutes, at 0℃ for 1 hour) followed by room cooling at 3 levels (-3℃ for 1 day, 0℃ for 1 day, 3℃ for 1 day). After initial cooling, the oak mushrooms were packaged with PVC film, then held in a storage room at 1℃ for 6 weeks. Quality characteristics and percentage marketability were then investigated. As a control, Mushrooms were placed in storage with no initial cooling. The quality factors impacting marketability of fresh oak mushrooms were color change and appearance of decay. Off-odor did not occur or developed only slightly, so it did not affect oak mushroom quality within 6 weeks of low temperature storage. In all treatment groups, the shelf life in which 100% marketability was maintained was up to 3 weeks. At week 5, percent marketability of the 3 treatment groups 1 hour room cooling treatment at 0℃, 1 hour forced air cooling, and control was 100%. 80% In the group that underwent 30 min forced air cooling retained 80% marketability, and the group exposed to 1 day in room cooling at -3℃ retained 86.7% marketability. At week 6 of 1℃ storage, the marketability ratio was 80% in the 1 day room cooling at 0℃ group, 66.7% in the 1 day room cooling at 3℃ group, 46.7% in the 1 hour forced air cooling group, and 33% or less in all other treatment groups. Therefore, the most suitable initial cooling parameter to extend shelf-life of oak mushrooms is 1 day of in room cooling at 0℃ immediately after harvest.

Deformation Analysis of Injection Molded Articles due to In-mold Residual Stress and Cooling after Ejection (사출 성형품의 금형내 잔류응력과 이형후 냉각에 의한 후변형 해석)

  • Yang, Sang-Sik;Kwon, Tai-Hun
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.251-256
    • /
    • 2001
  • Deformation analysis of injection molded articles whose geometry is considered as the assembly of the thin flat plates has been conducted. For the in-mold analysis, thermo-viscoelastic stress calculation of rheologically simple amorphous polymer and in-mold deformation calculation considering the in-plane mold constraint has been done. Free volume theory has been used for the non-equilibrium density state by the fast cooling. At ejection, the redistribution of stress together with instantaneous deformation has been considered. During out-of-mold cooling after ejection, thermoelastic model based on the effective temperature has been adopted for the calculation of deformation. Two typical mold geometries are used to test the numerical simulation.

  • PDF

Estimation of Hydrogen Filling Time Using a Dynamic Modeling (동적 모델링에 의한 수소 충전 시에 걸리는 시간의 산출)

  • NOH, SANGGYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.3
    • /
    • pp.189-195
    • /
    • 2021
  • A compressed hydrogen tank is to be repressurized to 40 bar by being connected to a high-pressure line containing hydrogen at 50 bar and 25℃. Hydrogen filling time and the corresponding hydrogen temperature has been estimated when the filling process stopped according to several thermodynamic models. During the process of cooling the hydrogen tank, hydrogen temperature and pressure vs. time estimation was performed using Aspen Dynamics. Filling time, hydrogen temperature after filling hydrogen gas, cooling time and the final tank pressure after tank filling process have been completed according to the thermodynamic models are almost same.

An Experimental Study of Dynamic Type Ice Storage System Using Magneticfluid (자성유체를 이용한 다이나믹형 빙축열 시스템에 관한 실험적 연구)

  • Hwang, Seung-Sic
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1484-1493
    • /
    • 2004
  • In this study, it induced to a conclusion below by experiment consideration to regarding an effective supercooling ends method of the flow cooling water in a tube of continuous ice making method and the static cooling water in a tube of continuous ice making method which used magneticfluid in a dynamic type ice storage system. Continuous ice making in a tube of the flow cooling water was shortened about 12 minutes until supercooling ends that case which gave vertical eccentricity rotation magnetic field 120rpm than did not provide magnetic field by experimental result that was tested to supercooling ends effect from shape control of magneticfluid. Continuous ice making method in a tube of the static cooling water compared with and reviewed the case that was not provided with the magnetic field and exposed cooling surface instantaneously by magnetic field. It confirmed that supercooling degree $\Delta$ $T_{c}$, $\Delta$ $T_{s}$, and $\Delta$ $T_{w}$ became lower because of heat transfering increasing by the occurrence of natural convection between after cooling starting progress time 1∼3 minutes if it did not give a magnetic field, and peformed the supercooling ends when natural convection occurred confirmed that refrigerating capacity was better. That relation $\Delta$ $T_{c}$, and $t_{e}$/($\Delta$ $T_{c}$-$\Delta$ $T_{s}$) after convection occurred, was not depended on $T_{b}$ and initial temperature if the depth of water and thickness of magneticfluid were regular and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.lar and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.c}$.>.

A Study about Change in the Temperature by Each Region and Time After Hot & Cold Application (온.냉적용시 신체부위별 및 시간에 따른 체온변화에 대한 연구)

  • Kim, Keun-Jo;Lee, Cu-Ri
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.3
    • /
    • pp.577-586
    • /
    • 1995
  • This paper was the study of a change in the body temperature of each region(Oral cavity, Axillary, Cubital, Popliteal, Inguinal region)and by time after appling hot(Hot Pack, Infra Red) and cold (Ice Pack, Cooling Pack) to lumbar region. The statistical measures were sampled through 16 senior students in dept. of Physiothrapy, Kim Cheun College and the period for this was from July 13, 1995 to July 20, 1995. There was an increse in the temperature of distal portion besides application area after hot application. The increse in the body temperature according to applied agents and time showed significance statistically(p<0.01, p<0.05). There was just a decrease in the temperature of distal portions besides application area after appling Ice Pack. Furthermore there was an increase in the body temperature after appling Cooling Towel. Therefore, during cold application the appling agents and time did not showed any significance statistically.

  • PDF