• 제목/요약/키워드: After-Cooling analysis

검색결과 337건 처리시간 0.031초

316L 시험원통의 열라체팅 구조시험에 관한 연구 (A Study on Thermal Ratcheting Structure Test of 316L Test Cylinder)

  • 이형연;김종범;구경회
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.243-249
    • /
    • 2001
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to $550^{\circ}$ and the temperature differences of about $500^{\circ}C$. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests.

  • PDF

박판재 변형의 가열교정에서 가열면적의 영향 (Effects of Heating Conditions in the Straightening of Sheet Metal Distortion)

  • 박준형;김재웅;김기철;전중환
    • Journal of Welding and Joining
    • /
    • 제26권4호
    • /
    • pp.79-84
    • /
    • 2008
  • Use of sheet metal structure is increased in various fields such as automobile, aerospace and communication equipment industry. When this structure is welded, welding distortion is generated due to the non-uniformity of temperature distribution. Recently welding distortion becomes a matter of great importance in the structure manufacture industry because it deteriorates the product's quality by bringing about shape error. Accordingly many studies for solving the problems by controlling the welding distortion are being performed. However, it is difficult to remove all kinds of distortion by welding process, though various kinds of methods for reducing distortion are applied to production. Consequently, straightening process is operated if the high precision quality is requested after welding. The local heating method induces compression plastic deformation by thermal expansion in the heating stage and then leaves constriction of length direction in the cooling stage. Accordingly, in the case of sheet metal structure, straightening effect is expected by heating for the part of distortion. This study includes numerical analysis of straightening effect by the local heating method in distortion comes from production of welded sheet metal structure. Particularly straightening effect followed by dimensions of heating area is analyzed according to the numerical analysis. The numerical analysis is performed by constructing 3-dimensional finite element model for 0.4mm stainless steel-sheet metal. Results of this study confirm that straightening effect changes as heating area increases and the optimum value of heating area that proves the maximum straightening effect exists.

태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구 (Demonstration study on Heating and Hot water According to Control Condition of Solar System)

  • 곽희열;김정배;주홍진;김종보
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.119-126
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $350m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

우리나라-노르웨이 고등어산업의 유통 경쟁력 비교 연구 (Comparison of Distribution Competitiveness of the Mackerel Industry between Korea and Norway)

  • 김대영;강종호
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1685-1692
    • /
    • 2015
  • This study examines the mackerel distribution systems in Norway which has a leading mackerel industry, and has the purpose of analyzing the effects of structural improvements for the development of Korea's mackerel industry. The landing and distribution status of Korea and Norway's mackerel industry was compared, and the effects of structural improvements was analyzed under the assumption that a number of factors would be improved after an analysis of competitiveness. Special features of the landing and distribution systems of mackerel in Norway are Reduction of transportation costs and transportation time through E-auctions, fish Pumps, freshness management using state-of-the-art equipment and technology such as sea water cooling systems, direct landing at processing factories and Automation through fully automated sorting & packaging systems. The distribution competitiveness of Korea and Norway's mackerel industry was compared through the qualitative review of landing time and the length of distribution channel, distribution costs due to differences in trading method, quality and hygiene management and merchandising. For Korea's mackerel industry to have international competitiveness, they must have efficiency throughout the phases of landing, processing and distribution systems as observed in case of Norway.

평판-관 구조물 용접시 발생하는 응력 및 변형율에 관한 연구 (A study on the stress and strain during welding of plate-to-pipe joint)

  • 나석주;김형완
    • Journal of Welding and Joining
    • /
    • 제4권2호
    • /
    • pp.30-39
    • /
    • 1986
  • In manufacturing of pipe walls for boiler units, distortion can result in pipe-web-pipe joints from the nonuniform expansion and contraction of the weld metal and the adjacent base metal during heating and cooling cycle of the welding process. In this study, the stresses and strains during longitudinal welding of the plate-to-pipe joint were investigated. Using the method of successive elastic solution, longitudinal stresses and strains during and after welding were calculated from the information of temperature distributions obtained by Rosenthal's equations. In order to confirm the validity of the numerical results, the temperature and residual stress distributions were measured and compared with the calculated results. In spite of some assumptions, the one-dimensional analytical results of residual stresses were in fairly good agreement with the experimental ones. The residual stresses due to welding of plate-to-pipe joints are tensile near the weld line and compressive in the base metal as in the welding of plates. the amount and distribution of residual stresses were deeply dependent on the heat input ratio of the plate and pipe.

  • PDF

히트펌프 시스템의 시설원예 적용에 관한 실험적 연구 (An Experimental Study on Applying Heat Pump System to Facility Horticulture House)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

Mesospheric Temperatures over Apache Point Observatory (32°N, 105°W) Derived from Sloan Digital Sky Survey Spectra

  • Kim, Gawon;Kim, Yong Ha;Lee, Young Sun
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권2호
    • /
    • pp.119-125
    • /
    • 2017
  • We retrieved rotational temperatures from emission lines of the OH airglow (8-3) band in the sky spectra of the Sloan digital sky survey (SDSS) for the period 2000-2014, as part of the astronomical observation project conducted at the Apache Point observatory ($32^{\circ}N$, $105^{\circ}W$). The SDSS temperatures show a typical seasonal variation of mesospheric temperature: low in summer and high in winter. We find that the temperatures respond to solar activity by as much as $1.2K{\pm}0.8K$ per 100 solar flux units, which is consistent with other studies in mid-latitude regions. After the seasonal variation and solar response were subtracted, the SDSS temperature is fairly constant over the 15 year period, unlike cooling trends suggested by some studies. This temperature analysis using SDSS spectra is a unique contribution to the global monitoring of climate change because the SDSS project was established for astronomical purposes and is independent from climate studies. The SDSS temperatures are also compared with mesospheric temperatures measured by the microwave limb sounder (MLS) instrument on board the Aura satellite and the differences are discussed.

플랜트 부품용 상용 발수코팅의 고온 환경 고장 특성 비교 분석 (Failure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant)

  • 이병호;김혜영;현창용;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권1호
    • /
    • pp.78-82
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate failure characteristic and mechanism of four commercial water-repellent coatings for elevated temperature machinery applications. Method: Thermal degradation was performed for up to 64 thermal cycles. 1 cycle consists of 15 minute holding at 523K under 300rpm revolution and 15 minute-natural cooling. Contact angle was measured and microstructure of the coating layer was observed by using a scanning electron microscope. Results: Four kinds of commercial repellent coating showed hydrophobic or super-hydrophobic property implying that all coatings are suitable for room temperature application. Contact angle of three kinds of commercial coatings decreased rapidly after thermal exposure, while only one specimen having hydrophobic surface showed extremely slow degradation. Conclusion: Observed decrease in contact angle of the coatings were attributed to formation of macro-sized pores and disappearance of micro-protrusion during thermal exposure. Optimum water-repellent coating needs to be selected under the consideration of initial contact angle as sell as service temperature.

중탄소 고망간강의 합금원소와 열처리 조건이 미세조직과 기계적 특성에 미치는 영향 (Effect of Alloying Elements and Heat Treatment on the Microstructures and Mechanical Properties of Medium Carbon High Manganese Steels)

  • 이동수;박현균
    • 열처리공학회지
    • /
    • 제23권6호
    • /
    • pp.338-343
    • /
    • 2010
  • Mechanical properties and microstructures of medium carbon high manganese steels were investigated in terms of alloying elements such as Mn, C contents, and heat treatment condition. Austenite volume fraction was increased with increasing Mn content, leading to hardness decrease in the range of Mn content of above 10% after quenching and tempering. Such results are also supported by microstructural analysis and X-ray diffraction in that the increase in mangaese content results in the increase in austenite fraction. Studies on tempering condition indicated that not only hardness and tensile strength but also charpy impact values were reduced as tempering temperature were raised in the range of $250^{\circ}C$ to $600^{\circ}C$. It was also observed that fracture mode was changed from dimple to intergranular fracture. Such results are thought to be due to very fine carbide precipitation or impurity segreagation at grain boundaries as tempering temperature goes up. Heat treatment of Fe-5Mn-2Si-1Al-0.4C can be optimized by austenitizing at $850^{\circ}C$, air cooling and tempering at $250^{\circ}C$, resulting in 1950 MPa in Tensile strength, 17% in elongation and 23.3 $J/cm^2$ in charpy impact energy with high work hardening characteristics.

승용차 폐열 회수용 유기 랭킨 사이클 성능 분석 (Performance analysis of an organic Rankine cycle for waste heat recovery of a passenger car)

  • 김현진;문제현;유제승;이영성
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.87-94
    • /
    • 2013
  • Applicability of organic Rankine cycle for a passenger car with 3.5 L gasoline engine to convert low grade waste heat to useful shaft power has been numerically studied. Working fluid is R134a, and the Rankine cycle is composed of boiler for recovering engine cooling water heat, super heater for recovering exhaust gas heat, scroll expander for converting waste heat to shaft power, condenser for heat emission, internal heat exchanger, and feed pump. Assuming efficiencies of 90% for the heat exchangers, 75% for the scroll expander, and 80% for the feed pump, the Rankine cycle efficiency of 5.53% was calculated at the vehicle speed of 120 km/hr. Net expander shaft output after subtracting the power required to run the pump was 3.22 kW, which was equivalent to 12.1% improvement in fuel consumption. About the same level of improvement in the fuel consumption was obtained over the vehicle speed range of 60 km/hr~120 km/hr.