• Title/Summary/Keyword: Aerosol size distribution

Search Result 204, Processing Time 0.029 seconds

Changes in the Ångstrom Exponent during Aerosol Coagulation and Condensation

  • Jung, Chang H.;Lee, Ji Yi;Kim, Yong P.
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.304-313
    • /
    • 2012
  • In this study, the ${\AA}$ngstrom exponent for polydispersed aerosol during dynamic processes was investigated. Log-normal aerosol size distribution was assumed, and a sensitivity analysis of the ${\AA}$ngstrom exponent with regards the coagulation and condensation process was performed. The ${\AA}$ngstrom exponent is expected to decrease because of the particle growth due to coagulation and condensation. However, it is difficult to quantify the degree of change. In order to understand quantitatively the change in the ${\AA}$ngstrom exponent during coagulation and condensation, different real and imaginary parts of the refractive index were considered. The results show that the ${\AA}$ngstrom exponent is sensitive to changes in size distribution and refractive index. The total number concentration decreases and the geometric mean diameter of aerosols increase during coagulation. On the while, the geometric standard deviation approaches monodispersed size distribution during the condensation process, and this change in size distribution affects the ${\AA}$ngstrom exponent. The degree of change in the ${\AA}$ngstrom exponent depends on the refractive index and initial size distribution, and the size parameter changes with the ${\AA}$ngstrom exponent for a given refractive index or chemical composition; this indicates that the size distribution plays an important role in determining the ${\AA}$ngstrom exponent as well as the chemical composition. Subsequently, this study shows how the ${\AA}$ngstrom exponent changes quantitatively during the aerosol dynamics processes for a log-normal aerosol size distribution for different refractive indices; the results showed good agreement with the results for simple analytic size distribution solutions.

Study of Retrieving the Aerosol Size Distribution from Aerosol Optical Depths (에어로졸 광학깊이를 이용한 에어로졸 크기분포 추출 연구)

  • Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.4
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, aerosol size distributions were retrieved from aerosol optical depth measured over a range of 10 wavelengths from 250 to 1100 nm. The 10 wavelengths were selected where there is no absorption of atmospheric gases. To obtain the solar spectrum, a home-made solar tracking system was developed and calibrated. Using this solar tracking system, total optical depths (TODs) were extracted for the 10 wavelengths using the Langley plot method, and aerosol optical depths (AODs) were obtained after removing the effects of gas absorption and Rayleigh scattering from the TODs. The algorithm for retrieving aerosol size distributions was suggested by assuming a bimodal aerosol size distribution. Aerosol size distributions were retrieved and compared under various arbitrary atmospheric conditions. Finally, we found that our solar tracking spectrometer is useful for retrieving the aerosol size distribution, even though we have little information about the aerosol's refractive index.

The Construction and Application of Effective Coefficient for Aerosol Size Distribution

  • Lin, Tang-Huang;Liu, Gin-Rong;Chen, A.J.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.594-596
    • /
    • 2003
  • Due to the fact that the composition and variability of aerosols is considered rather complex, it is difficult to employ a simple and straightforward physical model in calculating the aerosol size distribution in the absence of actual data. This complicates the already difficult retrieval of various atmospheric parameters from remotely sensed data. Thus, the main purpose of this study is trying to find an effective aerosol size coefficient that is stable, and can depict the particle size distribution. This paper also attempts to construct an 'effective aerosol size coefficient' database for each respective season, where it can quickly and effectively supply pertinent information of the atmosphere's opacity.

  • PDF

Physical Characteristics of Atmospheric Aerosols in Seoul : Scattering of Visible Light (서울 대기 Aerosol의 물리적 특성 : 가시광선의 산란)

  • 김필수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.28-37
    • /
    • 1988
  • Light scattering coefficient of visible light by atmospheric aerosol over the size range 0.01-10$\mu$m is determined from scattering efficiency and aerosol size distribution. Aerosol number distribution as a function of particle diameter dN/dlog D decreases rapidly as increasing particle size. Distribution of scattering coefficient d$\sigma_s/dlog$ D is mostly accumulated in diameter 0.1-2.0 $\mu$m showing its maximum in the vicinity of 0.6$\mu$m. This means that the visible light in the atmosphere is mainly scattered by these particles. Diurnal variation of scattering coefficient $\sigma_s$ appears its maximum in the morning, while minimum in the afternoon which agrees with the aerosol number distribution in the size range 0.1-2.0 $\mu$m.

  • PDF

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.

  • PDF

Experimental and Numerical Study of Aerosol Coagulation by Gravitation (에어로졸 입자의 중력응집에 관한 실험 및 수치적 연구)

  • 권순박;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • The behavior of aerosos due to gravitational coagulation was studied experimentally and numerically. In experimental study, the geometric mean particel size increased as time elapsed in a vertical tube column, while the size decreased when the tube was set horizontally. The particle size distribution was observed to maintain the lognormal form during the coagulation process. Separately, numerical calculations were performed for studying the aerosol behavior under gravitational and Brownian coagulation using the moment method. By comparing the expeimented results with the numerical predictions, the governing mechanism of the aerosol behavior proved to be gravitational coagulation.

  • PDF

Prediction of Temporal Variation of Son Concentrations in Rainwater (산성비 모델을 이용한 시간별 강우성분 예측)

  • 김순태;홍민선;문수호;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.191-204
    • /
    • 2003
  • A one dimensional time dependent acid rain model considering size distribution of aerosols and hydrometeors is developed to predict observed chemical and physical properties of precipitation. Temporal variations of anions and cations observed are predicted fairly well with acid rain model simulations. It is found that aerosol depletion rates are highly dependent on aerosol sizes under the assumption of Marshall - Palmer raindrop size distribution. Also, the aerosol depletion during the initial rain event largely influences on ion concentrations in rainwaters.

Recent Development of Analytical Solutions to Brownian Aerosol Coagulation in Different Particle Size Regimes

  • Park, Seong-Hun;Kim, Hyun-Tae;Lee, Kyoo-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.65-71
    • /
    • 1999
  • The log-normal size distribution theories developed recently for aerosol coagulation are reviewed. The analytical solutiosn to Brownian coagulation developed recently for various particle size regimes are reviewed. In order to describe the evolution of the size distribution of a coagulating aerosol over the entire size range, the analytical solutions developed individually for the free-molecule regime, the transition regime, the nearcontinuum regime, and the continuum regime have been combined. The work described here represents the first analytical solution to the aerosol coagulation problem covering the entire particle size range.

  • PDF

Size Measurement of Radioactive Aerosol Particles in Intense Radiation Fields Using Wire Screens and Imaging Plates

  • Oki, Yuichi;Tanaka, Toru;Takamiya, Koichi;Osada, Naoyuki;Nitta, Shinnosuke;Ishi, Yoshihiro;Uesugi, Tomonori;Kuriyama, Yasutoshi;Sakamoto, Masaaki;Ohtsuki, Tsutomu
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.216-221
    • /
    • 2016
  • Background: Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. Materials and Methods: A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of $^{11}C$-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. Results and Discussion: The size distribution for $^{11}C$-bearing aerosol particles was found to be ca. $70{\mu}m$ in geometric mean diameter. The size was similar to that for $^7Be$-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. Conclusion: The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

A Characteristic Study of the Aerosol Size Distribution in Pohang Province (포항 지역 대기에서 측정된 에어로졸 입자분포 특성 연구)

  • Seo, Moon Hyeok;Chang, Hyuk Sang
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.151-160
    • /
    • 2012
  • Health effects caused by the ultrafine particles in ambient air are great concern to the public health, and the strict measuring and monitoring of the ambient aerosol are required. In this work, the characteristics of the aerosol size distribution in Pohang province are studied. Optical particle counters (Grimm APS 1108 and 1109) were used to measure the aerosol size distribution in the area. Locations near the national monitoring site located in the industrial and the residence area were selected for the measuring sites of this study, and the locations in border area between the industry and the residence were selected for the reference of the comparison. In the industry site, it is found that the concentration of aerosol particles near the size of 5 ${\mu}m$ appear characteristically and the fluctuations in concentration with respect to time are minimal. The mass concentration of the aerosol above 10 ${\mu}m$ in diameter in the industry area was found to fluctuate significantly. The mass portion of $PM_{10}$ and PM2.5 to TSP in the residence area were 83% and 51% respectively. In the industrial regional, it was found that the mass portion of PM10 and $PM_{2.5}$ to TSP were 76% and 35% respectively. In the boundary area the mass portion of $PM_{10}$ and $PM_{2.5}$ to TSP were 78% and 54% respectively.