• Title/Summary/Keyword: Aerosol data

Search Result 365, Processing Time 0.061 seconds

Recent Research and Development on Aerosol Cyclones-Review

  • Lee, K.W.;Kim, H.T.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.59-68
    • /
    • 2000
  • In this paper Various aerosol cyclones that are developed recently form Kwangju Institute of Science and Technology(KJIST) for increasing collection efficiency or for decreasing pressure drop are reviewed. For the first time, new sets of experimental data are reported on the particle collection efficiency of cyclones with modified surface bodies namely, spiral guide body, circumferential groove body, and vertical groove body. Multi-cylinder cyclones by adding one or two additional cylindrical walls into the conventional cyclone are also described. Ad an attempt to increase the collection efficiency of small particles, electrocyclone using an externally applied electric field was designed and operated. In addition, factors affecting the cyclone performance were studied including flowrate, body and outlet sizes, cyclone dust outlet, and gas property.

  • PDF

Performance Comparison of the LRF and CCD Camera under Non-Visibility (Dense Aerosol) Environments (비 가시 환경에서의 LRF와 CCD 카메라의 성능비교)

  • Cho, Jai Wan;Choi, Young Soo;Jeong, Kyung Min
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.5
    • /
    • pp.367-373
    • /
    • 2016
  • In this paper, range measurement performance of LRF (Laser Range Finder) module and image contrast of color CCD camera are evaluated under the aerosol (high temperature steam) environments, which are simulated severe accident conditions of the LWR (Light-Water-Reactor) nuclear power plant. Data of LRF and color CCD camera are key informations, which are needed in the implementation of SLAM (Simultaneous Localization and Mapping) function for emergency response robot system to cope with urgently accidents of the nuclear power plant.

Theoretical and experimental study for optimization method of particle removal fibrous filter used in ventilation system (입자 제거용 환기 필터의 설계 변수 선정 기법을 위한 이론 및 실험적 연구)

  • Jung, Yee-Kyeong;Noh, Kwang-Chul;Park, Jae-Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • Pressure drop and particle removal efficiency of two commercial fibrous medium filters were measured with 20~1,000 nm sized aerosolized KCl particles. Pressure drop and particle removal efficiency were also theoretically predicted and the results qualitatively agreed with the experimental data. For this given particle removal efficiency, a filter design method for obtaining minimum pressure drop (and therefore minimum fan power) was suggested in this study by selecting solidity and fiber diameter as parameters. Therefore, by carrying out theoretical and experimental approaches together, this paper introduced a way of finding conditions for low pressure drop and high performance of a fibrous filter, especially if the filter would be used in mechanical ventilation system.

  • PDF

A Study of High Particle Collection Efficiency of Cyclone (고효율 사이클론의 집진효율에 관한 연구)

  • Chung, Jin-Do;Lee, Sang-Gwon;Bohnet, M.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2227-2232
    • /
    • 2003
  • For a reasonable analysis of grade efficiency of cyclone separator, in-line measurements of particle size and particle concentration are needed. The purpose of this study is to define the correlation of measurement data and to measure grade efficiency and pressure drop. The authors adapted that the grade efficiency could be calculated directly from the counted particle numbers. The problem of collection efficiency calculation was different from counting rate of aerosol counters under the same conditions. It is important factor to use the rate of the particle counters to obtain reliable results. Therefore, the authors should use and calculate compensation factor considering sensitivity of aerosol counters, gas velocity and concentration affect higher 30% than originally measured grade efficiency. As the pressure drop and grade efficiency increase, as flow rate increase and then also pressure drop and grade efficiency increase.

  • PDF

Quantitative Source Estimation of Particulate Matters in Pusan Area Using the Target Transformation Factor Analysis (Target Transformation Factor Analysis를 이용한 부산시 분진오염원의 양적 추정)

  • 김태오;김동술;나진균
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.2
    • /
    • pp.135-146
    • /
    • 1990
  • The purpose of the study was to identify sources of particulate matters statistically and to estimate the mass contribution quantitatively in the Pusan metropolitan area. Then, the study has used the TTFA (target transformation factor analysis) model, a receptor model, to apportion aerosol mass with the raw data of 106 ambient samples characterized by 24 heavy metal variables. The TTFA was extensively applied to generate source profiles and their aerosol mass contributions. Though a couple of sources were not identified, four to seven sources were able to be extracted at 3 different sites (Jang Rim-Dong, Kwang Bok-Dong, and Kwang An-Dong) in Pusan area and finally mass conributions could be calculated.

  • PDF

Size Distribution Characteristics of Particulate Matter Emitted from Cooking (조리과정에서 생성된 미세먼지의 크기분포 특성)

  • Joo, Sang-Woo;Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.

Mist Formation Characteristics in Turning (선삭 가공시의 미스트 발생 특성)

  • 오명석;고태조;박성호;김희술;정종운
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.147-152
    • /
    • 2002
  • The mechanism of the aerosol(mist) generation generally consists of spin-off, splash, and evaporation/condensation. Host researchers showed some theoretical model for predicting the particulate size and generation rate without real cutting in turning operation. These models were based on the spin-off mechanism, and verified good for modeling the process. However, in real machining, the cutting tool destroys the flow direction of the cutting fluid and generate the heat by the relative motion of between tool and workpicee, and so the mass loading of the mist is greatly increased as compared with non-cutting. In this paper, we show some experimental data that the mist formation characteristics of cutting is different from that of non-cutting.

  • PDF

Analysis of spray sodium fire phenomena in the containment vessel (격납용기내에서 분무형 나트륨화재 현상 해석)

  • 조병렬;권선길;황성태
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.79-88
    • /
    • 1996
  • A hypothetical accident in the containment vessel of liquid metal reactor could cause a pressure, temperature rise, and a strong aerosol release. The computer codes relating to the modelization of these accident make it necessary to use various input parameter, among which is the dynamic shape factor of aerosols produced. Combustion experiments of sodium spray fire carried out in a closed vessel, which was vertical cylinder made of 1.2m in diameter and 1.8m hight with a volume of 1.7$m^3$. The results of theoretical analysis presented here was compared to data obtained from experiments. The experimental results were summarized as follows. 1) The aerodynamic diameter and geometric diameter of aerosols are decreasing with increasing of injection pressure and injection temperature of sodium 2) The dynamic shape factor of aerosol is proportional to the aerodynamic diameter for a given particle. 3) The correspondence between the aerodynamic diameter and geometric diameter can be as $D_{ae}=0.70 D_{ge}$. 4) Peak pressure rose with increase in pressure and temperature of injection sodium, being more sensitive to the injection pressure than the injection temperature.

  • PDF

Intercomparing the Aerosol Optical Depth Using the Geostationary Satellite Sensors (AHI, GOCI and MI) from Yonsei AErosol Retrieval (YAER) Algorithm (연세에어로졸 알고리즘을 이용하여 정지궤도위성 센서(AHI, GOCI, MI)로부터 산출된 에어로졸 광학두께 비교 연구)

  • Lim, Hyunkwang;Choi, Myungje;Kim, Mijin;Kim, Jhoon;Go, Sujung;Lee, Seoyoung
    • Journal of the Korean earth science society
    • /
    • v.39 no.2
    • /
    • pp.119-130
    • /
    • 2018
  • Aerosol Optical Properties (AOPs) are retrieved using the geostationary satellite instruments such as Geostationary Ocean Color Imager (GOCI), Meteorological Imager (MI), and Advanced Himawari Imager (AHI) through Yonsei AErosol Retrieval algorithm (YAER). In this study, the retrieved aerosol optical depths (AOD)s from each instrument were intercompared and validated with the ground-based sunphotometer AErosol Robotic NETwork (AERONET) data. As a result, the four AOD products derived from different instruments showed consistent results over land and ocean. However, AODs from MI and GOCI tend to be overestimated due to cloud contamination. According to the comparison results with AERONET, the percentage within expected errors (EE) are 36.3, 48.4, 56.6, and 68.2% for MI, GOCI, AHI-minimum reflectivity method (MRM), and AHI-estimated surface reflectance from shortwave Infrared (ESR) product, respectively. Since MI AOD is retrieved from a single visible channel, and adopts only one aerosol type by season, EE is relatively lower than other products. On the other hand, the AHI ESR is more accurate than the minimum reflectance method as used by GOCI, MI, and AHI MRM method in May and June when the vegetation is relatively abundant. These results are explained by the RMSE and the EE for each AERONET site. The ESR method result show to be better than the other satellite product in terms of EE for 15 out of 22 sites used for validation, and they are better than the other product for 13 sites in terms of RMSE. In addition, the error in observation time in each product is found by using characteristics of geostationary satellites. The absolute median biases at 00 to 06 Universal Time Coordinated (UTC) are 0.05, 0.09, 0.18, 0.18, 0.14, 0.09, and 0.10. The absolute median bias by observation time has appeared in MI and the only 00 UTC appeared in GOCI.